    Oper at ion Ma nual Smart- UPS ™ Un interr upt ible Po wer S up ply To w e r 750/1000/1 500/2200/3 000 V A 100/ 120 /23 0 V a c 500 V A 100 V a c ...

  • APC SMT1500I-BNDL - page 2

    ...

  • APC SMT1500I-BNDL - page 3

    1 Smar t-UPS 750/1 000/1500/ 2200/30 00 VA 100/120/230 Vac / 500 VA 100 Vac Tower Overv iew Produc t Description The A PC ™ by Schnei der Electr ic Smart-UP S ™ is a high perform ance uninterrupt ible power supply (UPS ). The UPS pr ovides p rotect ion fo r elect ronic equipment from utili ty powe r bla ckouts, brownouts , sa gs, an d sur ges, ...

  • APC SMT1500I-BNDL - page 4

    Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/230 Vac / 500 VA 100 Vac Towe r 2 S pecification s For addi tional spe cific atio ns , refer to the APC by Schneider Elect ric W e b si te at www .apc.com . Envi ronment al Te m p e r a t u r e Oper at ing 0° to 40° C (32° t o 104° F) St o r a g e -15° to 45° C (5° to 1 13° F) char ge UPS bat ...

  • APC SMT1500I-BNDL - page 5

    3 Smar t-UPS 750/1 000/1500/ 2200/30 00 VA 100/120/230 Vac / 500 VA 100 Vac Tower Prod uct Over view Front panel fea tures Rear pan el feat ure s 500 V A t o 1500 V A model s 1 Di spla y inte rface 500/750/1000/ 1500 V A 2200/3000 V A 2 Be zel 3 Ba tte ry 4 Inte rnal b attery c onnect or 1 USB port 500/750 V A 100 V ac 750 V A 120 V ac 750 V A 230 ...

  • APC SMT1500I-BNDL - page 6

    Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/230 Vac / 500 VA 100 Vac Towe r 4 Rear pan el f eature s 2200 V A and 300 0 V A mode ls Inst allation For UPS inst allation informat ion, refer to the Smart-UPS Ins tallati on Guide 750/1 000/1500/ 2200/3000 V A 100/ 120/ 230 V ac, 500 V A 100 V ac T ower, that is incl uded with the UPS. The Inst all ...

  • APC SMT1500I-BNDL - page 7

    5 Smar t-UPS 750/1 000/1500/ 2200/30 00 VA 100/120/230 Vac / 500 VA 100 Vac Tower Operat ion Conn ect E quipm ent Note: The 2200/ 3000 V A 100 V a c model UPS wil l charge to 90% c apacity i n the first four and a ha lf hours of normal ope ration. All oth e r models will char ge to 90% capacit y in the firs t three hours of normal ope ration Do not ...

  • APC SMT1500I-BNDL - page 8

    Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/230 Vac / 500 VA 100 Vac Towe r 6 Displa y Pan el Usi n g th e dis play in ter fac e Us e t he U P / D OW N arro w butto ns t o scroll throug h the main men u opti ons. P ress ENTER to vi ew the submenus under each main menu optio n. Press ESC APE to exit a s ubm enu and ret urn to a m ain men u. St ...

  • APC SMT1500I-BNDL - page 9

    7 Smar t-UPS 750/1 000/1500/ 2200/30 00 VA 100/120/230 Vac / 500 VA 100 Vac Tower Ad va nc ed me nu s The Advan ced menus provide additi onal opti ons f or the UPS and ar e availabl e only if the dis play interfa ce is configu red to use the Advanced me nus. Me nu Gene ral F unc ti ons St a t u s V iew det ail ed UPS infor matio n: • Ope rati ng ...

  • APC SMT1500I-BNDL - page 10

    Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/230 Vac / 500 VA 100 Vac Towe r 8 Config uration UP S Sett ing s St ar t up S ettings Configure the se se ttings a t i nitia l st art up, usin g the di spla y interfa ce. As an alter native, configu ration can be perform ed using PowerChut e ™ software. Note: Dur ing s tart up, u se the dis play in ...

  • APC SMT1500I-BNDL - page 11

    9 Smar t-UPS 750/1 000/1500/ 2200/30 00 VA 100/120/230 Vac / 500 VA 100 Vac Tower Low T ransf er Point 100 V ac: 92 V ac 86 V a c - 92 V ac Set th e tr an s fe r po i nt lo w er if th e uti lit y vol ta g e is chr onicall y low and the connect ed equipm ent ca n tole ra te thi s c o ndi tio n.T h is s et tin g m a y al so b e ad j us ted usi ng the ...

  • APC SMT1500I-BNDL - page 12

    Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/230 Vac / 500 VA 100 Vac Towe r 10 Main Outlet Grou p and Controlled Outlet Gr oup Ov er vi ew The Main Outle t Group and the Control led Outle t Group can be configure d to inde penden tly turn of f, turn on, s hut down, and reboot connecte d equi pm ent . (These feat ures are not avai lable on the ...

  • APC SMT1500I-BNDL - page 13

    11 Smar t-UPS 750/1000/ 1500/220 0/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower Cu stom ize th e M a in and C ont ro lled Out l et G ro u ps Us e t he Configur ation menus to cha nge the Main Outl et Group and the Cont rolled Outl et Group sett ings. N etw or k Ma nage ment Ca rd Set ti ngs These se ttings are avai lable onl y on units that have ...

  • APC SMT1500I-BNDL - page 14

    Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/230 Vac / 500 VA 100 Vac Towe r 12 Emergen cy Power Of f Ov er vi ew The Emerge ncy Power Off (E PO ) optio n, is a safety fe ature that wil l immediately disconn ect all connec ted equipm ent f rom util ity power . The UPS will immedia tely s hut down and wi ll no t switc h to battery powe r . Adh e ...

  • APC SMT1500I-BNDL - page 15

    13 Smar t-UPS 750/1000/ 1500/220 0/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower T r oublesh ooting Pr oblem and Po ssible Cause Solution The UPS w ill n o t turn on o r there is no outp ut The uni t has not been tur ned on. Pre ss the ON key once t o t urn on t he UPS. Th e UPS is not con n ect ed to u tilit y po we r . Be sure th e powe r cable ...

  • APC SMT1500I-BNDL - page 16

    Smart-UPS 750/ 1000/1 500/2200/300 0 VA 100/ 120/230 Vac / 500 VA 100 Vac Towe r 14 Se rvice If th e unit re qui re s se r vi ce, d o no t ret ur n it to t he de al er . Fol lo w t he se steps: 1. Review the T roub lesh ooting sect ion of the ma nual to elimin ate com mon pr oblem s. 2. If the proble m persi sts, conta ct APC by Schneider E lectric ...

  • APC SMT1500I-BNDL - page 17

    15 Smar t-UPS 750/1000/ 1500/220 0/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower T wo Y e ar Limited Fac tory W arranty Schneid er Electri c IT Corpora tion (SEIT ), wa r rants its produc ts to be free from defect s in mater ials and workmanshi p for a period of t h ree (3) years e xcluding t he batte ries, whi ch are wa rranted for two (2) ye ars ...

  • APC SMT1500I-BNDL - page 18

    03/20 13 EN 990- 3534 D APC by Schne ider Electric World wide Cust omer Support Customer suppor t for this or any othe r APC by Schneider Elect ric product is avail able at no charge in any of the followi ng ways: • V isit the APC by Schne ider Electric W eb site to access documen ts in the APC by Schneide r Electr ic Knowledg e B ase and to subm ...

Fabricante APC Categoría Uninterruptible power supply (

Los documentos del dispositivo APC SMT1500I-BNDL que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos APC
- manuales de instrucciones SMT1500I-BNDL
- hojas de producto APC
- folletos informativos
- o etiquetas energéticas APC SMT1500I-BNDL
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones APC SMT1500I-BNDL.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje APC SMT1500I-BNDL, instrucciones de servicio, instrucciones cortas o instrucciones de usuario APC SMT1500I-BNDL. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto APC SMT1500I-BNDL.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo APC SMT1500I-BNDL, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar APC SMT1500I-BNDL. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de APC SMT1500I-BNDL.

El manual de instrucciones completo de APC debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual APC SMT1500I-BNDL - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice APC SMT1500I-BNDL, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de APC SMT1500I-BNDL que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo APC SMT1500I-BNDL - que deben facilitarnos los primeros pasos durante el uso de APC SMT1500I-BNDL
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con APC SMT1500I-BNDL
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de APC SMT1500I-BNDL en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de APC SMT1500I-BNDL?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con APC SMT1500I-BNDL, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con APC SMT1500I-BNDL probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen