Manual de instrucciones Lennox International Inc. 51M32

14 de páginas 0.16 mb
Descargar

Pasar a la página of 14

Summary
  • Lennox International Inc. 51M32 - page 1

    Page 1 ®  2003 Lennox Industries Inc. Dallas, T exas, USA OPERA TION MANUAL Merit R Series Thermost at The Lennox Merit ® Series Thermostat 51M32 is a nonpro- grammable electronic thermostat that is easy-to-use and has a large, easy-to-read display and excellent tempera- ture control. The thermostat also includes a programmable filter change r ...

  • Lennox International Inc. 51M32 - page 2

    Page 2 Display − Home Screen Figure 2 ROOM 70 FA N AUTO SYSTEM HEA T Figure 2 illustrates the HOME screen. Note that an indoor room temperature of 70°F is initially displayed. After about 1 minute of warm−up time, the actual room temperature will be displayed. HEA T mode is the system default (as indi- cated in the SYSTEM box at lower right). ...

  • Lennox International Inc. 51M32 - page 3

    Page 3 Figure 6 Heating Demand ROOM 72 88 FA N AUTO SYSTEM HEA T When the actual temperature rises above the temperature setpoint, the flame icon will disappear . This indicates that th e heating demand has been satisfied and that the heating equipment has been turned off. NOTE − The heating equipment is activated for at least 3 minutes if no but ...

  • Lennox International Inc. 51M32 - page 4

    Page 4 Fan Control The F AN button is located behind the small door on the right-hand side of the thermostat. See figure 3. The F AN button can be used to select either continuous fan mode or auto fan mode. If continuous fan mode is enabled, the fan will run continu- ously regardless of whether the heating or cooling equip- men t is running. Also, ...

  • Lennox International Inc. 51M32 - page 5

    Page 5 Service Indicator When abnormal equipment operation is detected, the SER VICE indicator will flash on the upper-right corner of the screen. This indicates that the equipment requires ser- vice from a qualified service technician. The SER VICE indi- cator is shown in figure 13. Figure 13 Service Indicator Flashing ROOM 73 SERVICE FA N AUTO SY ...

  • Lennox International Inc. 51M32 - page 6

    Page 6 Equipment Protection Override Both the minimum compressor OFF timer and the mini- mum equipment cycle timer can be over−ridden by press- in g and holding either the HEA T or COOL button down for 4 seconds. Over−T emperature Protection Thermal mechanical switch opens W1 at 93°F+/−6°F . Filter Reminder Settings o f 0 ( O f f), 1, 3, 6 ...

  • Lennox International Inc. 51M32 - page 7

    Page 1 ®  2003 Lennox Industries Inc. Dallas, T exas, USA OPERA TION MANUAL Merit R Series Thermost at The Lennox Merit ® Series Thermostat 51M33 is a nonpro- grammable electronic thermostat that is easy-to-use and has a large, easy-to-read display and excellent tempera- ture control. The thermostat also includes a programmable filter change r ...

  • Lennox International Inc. 51M32 - page 8

    Page 2 Display − Home Screen Figure 2 ROOM 70 FA N AUTO SYSTEM HEA T Figure 2 illustrates the HOME screen. Note that an indoor room temperature of 70°F is initially displayed. After about 1 minute of warm−up time, the actual room temperature will be displayed. HEA T mode is the system default (as indi- cated in the SYSTEM box at lower right). ...

  • Lennox International Inc. 51M32 - page 9

    Page 3 Figure 6 Heat Mode Disabled ROOM SETPOINT 69 64 FA N AUTO SYSTEM OFF Heating Demand The thermostat must be in either normal or emergency heat mode in order to properly control the heating equip- ment. W hen in either heat mode, i f t he a ctual t emperature i s lower t han t he t emperature s etpoint, a h eating demand i s de- tected b y t h ...

  • Lennox International Inc. 51M32 - page 10

    Page 4 Setpoint Display and Adjustment Figure 9 ROOM SETPOINT 69 64 FA N AUTO SYSTEM HEA T Aft e r the desired setpoint is reached, the HOME screen will reappear after about 8 seconds. Fan Control The F AN button is located behind the small door on the right-hand side of the thermostat. See figure 3. The F AN button can be used to select either con ...

  • Lennox International Inc. 51M32 - page 11

    Page 5 Figure 13 Display of Filter Reminder ROOM 72 FIL TER FA N AUTO SYSTEM HEA T Balance Point NOTE − The balance point is only available with the out- door sensor . If the optional outdoor sensor (X2658) is connected to the thermostat, ba l ance point adjustment is available. The bal- ance point feature allows the measured outdoor tempera- tur ...

  • Lennox International Inc. 51M32 - page 12

    Page 6 Default Thermostat Settings Default Thermostat settings are in table 1. T able 1 Default Thermost at Settings Mode Heat Setpoint 70°F (or 21°C) Fan Auto Filter Reminder OFF (reminder setting = 0) Equipment Protection T imers reset back to zero T echnical Specifications Thermostat T ype Electronic nonprogrammable thermostat for 1H/1C, heat ...

  • Lennox International Inc. 51M32 - page 13

    Page 7 Service Reminder The SE RVICE indicator is displayed only under the follow- ing conditions:  if the thermostat Y1 terminal has been activated with 24V AC for at least 5 minutes, AND the L terminal is shorted to the R terminal; OR  if the thermostat Y1 terminal has been activated with 24V AC for at least 5 minutes, AND the L terminal is ...

  • Lennox International Inc. 51M32 - page 14

    Page 8 T able 3 Thermostat Output S tates Condition W1 Y1 G O E Electric Heat Backup − No Out door Sensor small heat demand X X large heat demand X X X emergency heat demand X X cool demand X X X no demand dc Gas Heat Backup (Dual Fuel) − No Out door Sensor small heat demand X X large heat demand X emergency heat demand X cool demand X X X no d ...

Fabricante Lennox International Inc. Categoría Thermostat

Los documentos del dispositivo Lennox International Inc. 51M32 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Lennox International Inc.
- manuales de instrucciones 51M32
- hojas de producto Lennox International Inc.
- folletos informativos
- o etiquetas energéticas Lennox International Inc. 51M32
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Lennox International Inc. 51M32.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Lennox International Inc. 51M32, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Lennox International Inc. 51M32. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Lennox International Inc. 51M32.

El manual de instrucciones del dispositivo Lennox International Inc. 51M32, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Lennox International Inc. 51M32. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Lennox International Inc. 51M32.

El manual de instrucciones completo de Lennox International Inc. debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Lennox International Inc. 51M32 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Lennox International Inc. 51M32, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Lennox International Inc. 51M32 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Lennox International Inc. 51M32 - que deben facilitarnos los primeros pasos durante el uso de Lennox International Inc. 51M32
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Lennox International Inc. 51M32
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Lennox International Inc. 51M32 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Lennox International Inc. 51M32?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Lennox International Inc. 51M32, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Lennox International Inc. 51M32 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (1)

Carlos mora

Hola buenos dias, a quien me pueda ayudar, tengo un equipo con un termostato, 51m32, le dieron al boton de reset, y ahora no sale de la pantalla de inicio, donde aparece room. 88 set point 88, que hago??