Manual de instrucciones Venmar HEPA 4100*

22 de páginas 4.25 mb
Descargar

Pasar a la página of 22

Summary
  • Venmar HEPA 4100* - page 1

    INST ALLA TION INSTR UCTIONS AND USER MANU AL RESIDENTIAL USE ONL Y INST ALLER: LEA VE THIS MANU AL WITH THE HOMEO WNER. HOMEO WNER: USE AND CARE INFORMA TION ON P AGES 18 T O 21. READ AND SA VE THESE INSTR UCTIONS 04313 re v . G MODELS ...

  • Venmar HEPA 4100* - page 2

    ABOUT THIS MANU AL First, we want to cong ratulate you on y our purchase of this excellent unit which will allo w you and y our family to enjo y clean and health y air throughout your home f or years to come! Because of the large amount of models cov ered by this pub lication, the illustrations are typical ones. Some details of your unit ma y be sl ...

  • Venmar HEPA 4100* - page 3

    1. T YPICAL I NST ALLA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 1.1 HR V 2600, HR 2.6, HEP A 3100, HF 3.1 AND HEP A 4100 U NIT I NST ALLA TIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1.1 S TA N D A LONE . . . . . . . . . . . . . . . . . . . . . . . ...

  • Venmar HEPA 4100* - page 4

    1. TYPICAL INST ALLA TIONS Installations ma y vary according to the model number and the position in which the unit is installed. Use the f ollowing illustr ations as guidelines to help you decide on ho w your unit will be installed. All the units should be hung from the joists, and installed either v er tically or horizontally . NO TE: F or more d ...

  • Venmar HEPA 4100* - page 5

    1. TYPICAL INST ALLA TIONS (CONT’D) ...

  • Venmar HEPA 4100* - page 6

    All 3 types of installations can be used in the attic (Stand Alone, Central Dr aw P oint or Retur n-Retur n). The example sho wn bel ow i s a Return-Retur n installation (connection to a forced air system). VH0051 - 6 - A por tion of stale air is exhausted to the outside and the rest is dr awn to the unit. Outside fresh air is blended with interior ...

  • Venmar HEPA 4100* - page 7

    - 7 - 2.3 M OUNTING AND S ER VICING C ONSIDERA TIONS • The two f ollowing pictures are showing the minim um clearance needed to open the door completely . 22.5” 15.75” (572 mm) (400 mm) VD0117 VD0116 22” (559 mm) NO TE: A minimum of 8” (203 mm) clearance from an y obstruction on top of the unit is required for the ductwork radius turn. 8? ...

  • Venmar HEPA 4100* - page 8

    - 8 - 3.3 L OCA TING THE U NIT Choose an appropriate location for the unit. • Within an area of the house where the ambient temperature is between 10°C (50°F) and 65°C (149°F) (basement, furnace room, closet, etc.). • So as to provide easy access to the interior of the unit, f or filter maintenance. • Close to an e xter ior wall, so as to ...

  • Venmar HEPA 4100* - page 9

    - 9 - 1. Route the cable from the unit to a con venient location f or the wall control. 2. Loosen the locking scre w (the screw cannot be completely remo ved). 3. Detach the f aceplate from the mounting plate by pulling the bottom par t. If necessar y , bore the mounting holes and inser t anchors. 4. P ass the cable (4 wires) through the opening of ...

  • Venmar HEPA 4100* - page 10

    7. T urn the unit switch knob to OFF position in order to unloc k the door. Unlatch the door and open it. If required, the door can be removed. T o do so , remov e the stopper ( A ) located on the right side of the door hinge. Then, hold the door and hit with your palm its left side . Slide the door to the right to disengage it from the unit. 8. Us ...

  • Venmar HEPA 4100* - page 11

    5.2 H OW TO H ANG THE U NIT Use the 4 chains and springs in the hardware pack pro vided with the unit. According to your needs , you can install the unit either in vertical or hor izontal position. VD0074 ...

  • Venmar HEPA 4100* - page 12

    - 12 - 5.3 P LANNING OF THE D UCTWORK All units in this manual are prebalanced. • K eep it simple. Plan for a minimum of bends and joints . • K eep the length of outside insulated duct to a minimum. • Do not v entilate cra wl spaces or cold rooms. Do not attempt to recover the e x haust air from a dryer or a range hood. This w oul d cause clo ...

  • Venmar HEPA 4100* - page 13

    5.4 I NST ALLING N ON -I NSULA TED D UCTS AND R EGISTERS ( CONT ’ D ) 5.4.1 S TA N D A LONE S YSTEM ( AS ILLUSTRA TED IN S ECTION 1.1.1) ( CONT ’ D ) A LL UNITS How to connect the fle xible duct to the unit ports • Using the colored stic ker dot included, identify which duct it is (red dot f or stale airflow and b lue dot for filtered airflo ...

  • Venmar HEPA 4100* - page 14

    5.4 I NST ALLING N ON -I NSULA TED D UCTS AND R EGISTERS ( CONT ’ D ) 5.4.2 C ENTRAL DRA W P OINT ( AS ILLUSTRA TED IN S ECTION 1.1.2) ( CONT ’ D ) Fresh/Filtered air ductwork (Return side connection) (cont’ d) HEP A 3100, HF 3.1 AND HEP A 4100 UNITS ONL Y ( CONT ’ D ) • Fix the duct connector to the f orced air unit duct using its 4 reta ...

  • Venmar HEPA 4100* - page 15

    5.5 I NST ALLING I NSULA TED F LEXIBLE D UCTS Use the f ollowing procedure f or connecting the insulated flexib le ducts to the T andem® transition* ( EXHA UST AIR TO OUTSIDE and FRESH AIR FROM OUTSIDE ). NO TE: If the joist are perpendicular to the ducts, or if the connection to the exterior hood is in a limited area, your installation will need ...

  • Venmar HEPA 4100* - page 16

    5.5 I NST ALLING I NSULA TED F LEXIBLE D UCTS ( CONT ’ D ) 5.5.2 C ONNECTION TO THE 5’ ’ TO 6’ ’ O V AL PORTS OF THE UNIT ( CONT ’ D ) 4. Apply duct tape gently to the joint in order to make an airtight seal. 5. Repeat steps 1 to 4 f or the other 5’ ’ to 6’ ’ por t. See figure beside to find the EXHA UST AIR T O OUTSIDE ( 1 ) an ...

  • Venmar HEPA 4100* - page 17

    5.6 I NST ALLING D UA L E XTERIOR H OOD ( CONT ’ D ) 5.6.3 C ONNECTING T ANDEM ® TRANSITION TO EXTERIOR D UAL H OOD ( CONT ’ D ) 2. Join the end of the T andem transition to the rear of the e xter ior backplate. Secure with 2 Xmas tree pins and seal properly with duct tape. 3. Lean the e xter ior bac kplate to the exterior wall. Using 4 #8 x 1 ...

  • Venmar HEPA 4100* - page 18

    6.1 M AIN S WITCH All units are equipped with a 3-position main s witch, located on the front panel. 6.2 40415 AND 40425 W ALL C ONTR OLS D ESCRIPTION The included wall control is 40415 (intented f or HR V 2600, HEP A 3100 and HEP A 4100 units only) or 40425 control (intented for HR 2.6 and HF 3.1 units only). The w all control is in OFF mode when ...

  • Venmar HEPA 4100* - page 19

    6.4 W ALL C ONTROLS C ONFIGURA TION See the configuration tab le below f or the list of configuration parameters. Press the Menu b utton for 3 seconds to enter or e xit the configuration menu. NO TE: The wall control automatically sav es any changes and e xits the configuration menu if no b utton is pressed within the ne xt 60 seconds. Press the Me ...

  • Venmar HEPA 4100* - page 20

    - 20 - 7. MAINTENANCE W ARNING Risk of electrical shocks. Before performing an y maintenance or servicing, al ways disconnect the unit fr om its power source. ! 7.1 B IANNU AL M AINTENANCE ( ESSENTIAL ) P erf or m this maintenance when the Filter Maintenance LED is flashing . F ollow these steps: 1. T urn switch knob to OFF to unloc k the door . 2. ...

  • Venmar HEPA 4100* - page 21

    - 21 - 7.1 B IANNU AL M AINTENANCE ( ESSENTIAL ) ( CONT ’ D ) 6. W ash the 2 core filters under hot water with mild soap . Rinse thoroughly and let dr y completely bef ore reinstalling on the core. Remove the dust on the core using a v acuum cleaner with a soft brush attachment. 1) Core filters 2) Core NO TE: Make sure the damper spring ( 1 ) is ...

  • Venmar HEPA 4100* - page 22

    If the problem is still not solv ed, call your installer or the nearest authorized Service Center . Also , you can reach the Customer Service Depar tment at one of the following telephone n umbers: Exclusively f or models HRV 2600, HEP A 3100 and HEP A 4100: Exclusively f or models HR 2.6 and HF 3.1: 1-800-567-3855. 1-866-737-7770. PROBLEMS SOLUTIO ...

Fabricante Venmar Categoría Ventilation Hood

Los documentos del dispositivo Venmar HEPA 4100* que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Venmar
- manuales de instrucciones HEPA 4100*
- hojas de producto Venmar
- folletos informativos
- o etiquetas energéticas Venmar HEPA 4100*
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Venmar HEPA 4100*.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Venmar HEPA 4100*, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Venmar HEPA 4100*. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Venmar HEPA 4100*.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Venmar HEPA 4100*, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Venmar HEPA 4100*. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Venmar HEPA 4100*.

El manual de instrucciones completo de Venmar debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Venmar HEPA 4100* - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Venmar HEPA 4100*, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Venmar HEPA 4100* que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Venmar HEPA 4100* - que deben facilitarnos los primeros pasos durante el uso de Venmar HEPA 4100*
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Venmar HEPA 4100*
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Venmar HEPA 4100* en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Venmar HEPA 4100*?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Venmar HEPA 4100*, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Venmar HEPA 4100* probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)