    AC P ow er For Business-Criti cal C on tinuity™ Li eber t ® NXL ™ S hip - Ahead I nput/O utput Cabinet Install atio n Manual – 250-400kV A, 60Hz ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 2

    C ONT ACTING L IEBERT FOR S UPPORT To contact Liebert Services for information or repair service in the United States, call 1-800-LIEBERT (1-800-54 3-2378). Liebert Services offe rs a complete range of start-up services, repair services, preventive maintenanc e plans and service contracts. For repair or mainten ance service ou tside the 48 co ntigu ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 3

    i T A BLE OF CONTENTS 1.0 M ECHANICA L I NST ALLATIO N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2 Preliminary Checks . . . . . . . . . . . . . . ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 4

    ii ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 5

    1 I MPORT ANT S AFETY I NSTRUCTIONS SA VE THESE INSTRUCTIONS This manual co ntains important ins tructions that should be followed during installation of your Lie- bert NXL ™ Input/Output Cabinet. Read this manual thoroughly, payi ng special attention to the sec- tions that apply to your instal lation, before working with the UPS. Retain this man ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 6

    Mechanical Installation 2 1.0 M ECHANICAL I NST ALLATION 1.1 Introduction This following se ction describes the requiremen ts th at must be taken into account when p lanning the positioning and cabling of the Li ebert NXL Input/Output Cabinet. This chapter is a guide to general procedures and pr actices that should be ob served by the installing pe ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 7

    Mechanical Installation 3 1.4.1 Moving the Cabinet s The Liebert NXL Input/Output Cabinet can be handled with a f orklift or similar equipment. When moving the unit by forklift, care must be take n to protect the panels. Do not exceed a 15-degree tilt with the forklift. Bott om structure will support the unit only if the forks are compl etely benea ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 8

    Electrical Installation 4 2.0 E LECTRICAL I NST A LLATION This chapter provid es guidelines fo r qualified install ers who must have knowledge of local wiring practices pertaining to the equipment to be installed. 2.1 External Protective Devices For safety, circuit breakers must be installed in the input AC supply and external ba ttery system. Give ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 9

    Electrical Installation 5 The following are guidelines only and are superseded by local regulations and codes of practice where applicable: • Take special care when determin ing the size of the neutral cable (grounded conductor), because current circulating on the neutra l cable may be greater than nomi nal current in the case of non- linear load ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 10

    Electrical Installation 6 Top Cable Entry When making the power connections, the recommended order of pulling and installing cables is to start from the top connections to the bottom connections. The cables must be routed around the fault braces (see Detail in Figure 3 ). This is to prevent the cables from contacting other busbars. The recommended ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 11

    Electrical Installation 7 Notes on T ables 1. Nominal input current (considered continuous) is based on full -rated output load. Maximum current includes nominal input current and ma ximum battery recharge current (considered noncontinuous). Contin uous and noncontin uous cu rrent are defined in NEC 100. Maximum input current is controlled by the c ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 12

    Electrical Installation 8 T able 6 Recommended lug size s Cable Size T&B Series 54000 One Hole T&B Series 54000 Two Hole #8 AWG 54930BE 54850BE #6 AWG 54905BE 256-30695-868 #4 AWG 54906BE 256-30695-733 #2-3 AWG 54942BE 54811BE #1 AWG 54947BE 54857BE #1/0 AWG 549 50BE 256-30695-593 #2/0 AWG 54951BE 54862BE #3/0 AWG 54965BE 54864BE #4/0 AWG 5 ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 13

    Installation Drawings 9 3.0 I NST ALLATION D RAWINGS Figure 1 Input/output conduit det ail dr awing, 250-3 00kV A Liebert NXL UPS OUT PU T NEUTRA L INNER P ANE L REMOVED FOR CLARIT Y SHOWN IN EXTENDE D POSI TIO N DC (2) 3 " CONDUI T NOTES: 1. ALL DIMENSIONS ARE IN inches (mm). 2. 24" MINIMUM CLE ARANCE A BOVE UNIT REQUIRED FOR AIR EXHAUST ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 14

    Installation Drawings 10 Figure 2 Input/output conduit det ail drawing, 400kV A Liebert NXL UPS NOTES: 1. ALL DIM ENSI ON S ARE IN inche s (mm ). 2. 2 4" MI NI MUM CLEARAN CE AB OVE UNI T REQ UIR ED FO R AI R EXHAUS T . 3. KE EP CABIN ET WI THI N 15 D EGREES OF VE R TI CAL. 4. T OP AND BO TTOM CABLE EN TR Y AV AI LABLE THR OUG H REMOV ABLE ACC ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 15

    Installation Drawings 11 Figure 3 T op cable entry routing and inst allation order The cables must be rout ed around the fault braces. This is to prevent the cables from coming in cont act with other busbars. F AUL T BRACE OUTPU T F AUL T BRACE RECTIFIER INPU T F AUL T BRACE BYP ASS IN PU T BYP ASS NEUT RA L DC (POSITIVE) DC ( NEG A T IVE) GROUND ( ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 16

    Installation Drawings 12 Figure 4 Bottom cable entry routing and inst allation order SIDE VIEW F AUL T BRACE OUTPU T F AUL T BRACE RECT IFI ER INPU T F AUL T BRACE BYP ASS INPU T BYP ASS NEUT RA L DC (POSITIVE) DC ( NEG A T IVE) GROU ND ( TO P E NT RY ) BYP ASS IN PU T RECTIFIER INPU T OUTPU T OUTPU T NEUTRA L GROUND (BOT TOM ENT RY) FRONT VIE W Re ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 17

    Installation Drawings 13 Figure 5 Floor mount bracket s—st andard and optional layout WA R N I N G Brackets MUST remain attached to the frame until the unit is being placed in its final installed position. (The final installation will always require the unit to be bolted to another Liebert NXL product.) Failure to comply with these instructions c ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 18

    Installation Drawings 14 ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 19

    ...

  • Liebert Ship-Ahead Input/Output Cabinet NXL - page 20

    EmersonNetworkPower.com Ensuring The Hi gh Av ailab ilit y 0f Mission-Critic al Data And Ap plic ations. Emerson Net work P ower , the global leader in enabling business-critical continuity , ensures network resilienc y and adaptability through a family of technologies—inc luding Liebert power and cooling technologies—that prot ect and suppor t ...

Fabricante Liebert Categoría Power Supply

Los documentos del dispositivo Liebert Ship-Ahead Input/Output Cabinet NXL que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Liebert
- manuales de instrucciones Ship-Ahead Input/Output Cabinet NXL
- hojas de producto Liebert
- folletos informativos
- o etiquetas energéticas Liebert Ship-Ahead Input/Output Cabinet NXL
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Liebert Ship-Ahead Input/Output Cabinet NXL.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Liebert Ship-Ahead Input/Output Cabinet NXL, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Liebert Ship-Ahead Input/Output Cabinet NXL. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Liebert Ship-Ahead Input/Output Cabinet NXL.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Liebert Ship-Ahead Input/Output Cabinet NXL, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Liebert Ship-Ahead Input/Output Cabinet NXL. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Liebert Ship-Ahead Input/Output Cabinet NXL.

El manual de instrucciones completo de Liebert debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Liebert Ship-Ahead Input/Output Cabinet NXL - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Liebert Ship-Ahead Input/Output Cabinet NXL, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Liebert Ship-Ahead Input/Output Cabinet NXL que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Liebert Ship-Ahead Input/Output Cabinet NXL - que deben facilitarnos los primeros pasos durante el uso de Liebert Ship-Ahead Input/Output Cabinet NXL
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Liebert Ship-Ahead Input/Output Cabinet NXL
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Liebert Ship-Ahead Input/Output Cabinet NXL en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Liebert Ship-Ahead Input/Output Cabinet NXL?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Liebert Ship-Ahead Input/Output Cabinet NXL, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Liebert Ship-Ahead Input/Output Cabinet NXL probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)