    Table of Contents ILMI Address Registration Problems: %LANE−3−NOREGILMI..............................................................1 Document ID: 10450 ................................................................................................................................1 Introduction ................................................. ...

  • Cisco Systems NOREGILMI - page 2

    ILMI Address Registration Problems: %LANE−3−NOREGILMI Document ID: 10450 Introduction Prerequisites Requirements Components Used Conventions Associated Error Message Configure Network Diagram Configurations Checking ILMI ILMI Status When ILMI is Disabled on the Switch Interface Access List Configuration Problems or ILMI Community Configured as ...

  • Cisco Systems NOREGILMI - page 3

    Conventions For more information on document conventions, refer to the Cisco Technical Tips Conventions. Associated Error Message Address resolution problems are usually associated with the following error message: %LANE−3−NOREGILMI: [chars] [chars] cannot register [ATM address] with ILMI For example: %LANE−3−NOREGILMI: ATM2/0/0.1 LEC canno ...

  • Cisco Systems NOREGILMI - page 4

    Configurations Both Bernard and Tintin are configured with a LEC: Bernard interface ATM2/0/0 pvc 0/16 ilmi ! pvc 0/5 qsaal ! interface ATM2/0/0.1 multipoint description *** ILMI addr. registr. test *** lane client ethernet ilmi−test Tintin interface ATM1/0 atm pvc 1 0 5 qsaal atm pvc 2 0 16 ilmi ! interface ATM1/0.1 multipoint description *** ILM ...

  • Cisco Systems NOREGILMI - page 5

    bernard# show atm ilmi−status Interface : ATM2/0/0 Interface Type : Private UNI (User−side) ILMI VCC : (0, 16) ILMI Keepalive : Disabled ILMI State: UpAndNormal Peer IP Addr: 10.200.10.12 Peer IF Name: ATM0/0/0 Peer MaxVPIbits: 8 Peer MaxVCIbits: 14 Active Prefix(s) : 47.0091.8100.0000.0060.3e5a.4501 Casimir# show atm ilmi−status atm 0/0/0 In ...

  • Cisco Systems NOREGILMI - page 6

    In this case, as ILMI has been disabled on the interface by issuing the no atm ilmi−enable command, the prefix is not sent to the router and hence, no address registration can occur. Access List Configuration Problems or ILMI Community Configured as Read−Only Access List configuration problems can occur if one of the workarounds proposed in thi ...

  • Cisco Systems NOREGILMI - page 7

    Casimir# show atm vc traffic interface atm 0/0/0 0 16 Interface VPI VCI Type rx−cell−cnts tx−cell−cnts ATM0/0/0 0 16 PVC 308 316 If you see only the sent or received counter incrementing, it may means that cells are being stuck on the backplane causing ILMI to be stuck. Try issuing a shut/no shut command on the interface. If that does not h ...

  • Cisco Systems NOREGILMI - page 8

    R I 1 ATM2/0/0 UP 0 47.0091.8100.0000.0060.3e5a.4501.0060.3e5a.4501/152 R I 1 ATM2/0/0 UP 0 47.0091.8100.0000.0060.3e5a.4501.0060.3e5a.4502/152 R I 1 ATM2/0/0 UP 0 47.0091.8100.0000.0060.3e5a.4501.0060.3e5a.4503/152 R I 1 ATM2/0/0 UP 0 47.0091.8100.0000.0060.3e5a.4501.0060.3e5a.4504/152 R I 1 ATM2/0/0 UP 0 47.0091.8100.0000.0060.3e5a.4501.0060.3e5a ...

  • Cisco Systems NOREGILMI - page 9

    If you look at Tintin, you can see that Tintin is already using that NSAP address and has registered it on Casimir: Tintin# show lane client LE Client ATM1/0.1 ELAN name: ilmi−test Admin: up State: operational Client ID: 2 LEC up for 39 seconds Join Attempt: 4 HW Address: 0000.0000.0001 Type: ethernet Max Frame Size: 1516 ATM Address: 47.00918100 ...

  • Cisco Systems NOREGILMI - page 10

    1w1d: ILMI(ATM2/0/0):Updating ES Database with 7.0091.8100.0000.0060.3e5a.4501.0060.3e5a.4502.00 1w1d: Reg Status :− Delete in progress − False, Add in progress − True 1w1d: ILMI(ATM2/0/0):Response received for request 930 1w1d: ILMI(ATM2/0/0): Errored response <General Error> Function Type = ilmiReqOther 1w1d: ILMI(ATM2/0/0): Errored o ...

  • Cisco Systems NOREGILMI - page 11

    lane config database test Tintin lane database test name ilmi−test server−atm−address 47.00918100000000603E5A4501.00603E5A4503.01 ! interface ATM2/0/0 no ip address no ip directed−broadcast logging event subif−link−status lane config fixed−config−atm−address lane config database test With this new configuration, a LECS has been co ...

  • Cisco Systems NOREGILMI - page 12

    The router does not receive its prefix and hence no address−registration can occur. When enabling debug atm ilmi atm 0/0/0 on the LightStream 1010, this can be seen when the atm 0/0/0 interface is brought up: !−−− Output suppressed. Apr 2 12:42:11.792: ILMI: My Device type is set to Node (ATM0/0/0) Apr 2 12:42:11.792: ILMI(ATM0/0/0): From N ...

Fabricante Cisco Systems Categoría Network Router

Los documentos del dispositivo Cisco Systems NOREGILMI que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Cisco Systems
- manuales de instrucciones NOREGILMI
- hojas de producto Cisco Systems
- folletos informativos
- o etiquetas energéticas Cisco Systems NOREGILMI
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Cisco Systems NOREGILMI.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Cisco Systems NOREGILMI, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Cisco Systems NOREGILMI. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Cisco Systems NOREGILMI.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Cisco Systems NOREGILMI, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Cisco Systems NOREGILMI. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Cisco Systems NOREGILMI.

El manual de instrucciones completo de Cisco Systems debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Cisco Systems NOREGILMI - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Cisco Systems NOREGILMI, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Cisco Systems NOREGILMI que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Cisco Systems NOREGILMI - que deben facilitarnos los primeros pasos durante el uso de Cisco Systems NOREGILMI
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Cisco Systems NOREGILMI
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Cisco Systems NOREGILMI en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Cisco Systems NOREGILMI?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Cisco Systems NOREGILMI, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Cisco Systems NOREGILMI probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)