Desa CCL3018PTA/NTA - page 1
Sav e this manual for future reference. For more information, visit www .desatech.com UNVENTED (VENT -FREE) GAS LOG HEA TER OWNER’S OPERA TION AND INST ALLA TION MANU AL Biltmore Split Oak, Seasonal Oak and Smok y Mountain Oak Logs V aria ble Manually-Contr olled Models Also Design-Cer tied As V ented Decorativ e Appliances 18", 24" ...
-
Desa CCL3018PTA/NTA - page 2
www .desatech.com 1 13097-01E 2 - ? ...
-
Desa CCL3018PTA/NTA - page 3
www .desatech.com 1 13097-01E 3 SAFETY INFORMATION - ? ...
-
Desa CCL3018PTA/NTA - page 4
www .desatech.com 1 13097-01E 4 4. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions • if you cannot reach your gas supplier, call the ...
-
Desa CCL3018PTA/NTA - page 5
www .desatech.com 1 13097-01E 5 Figure 1 - V ent-Free Gas Log Heater (Logs May V ary by Model, Seasonal Oak Single Burner Model Shown) Base Grate Log Set Control Knob Burner Piezo Ignitor PRODUCT IDENTIFICATION PRODUCT FEA TURES OpERA TION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney ...
-
Desa CCL3018PTA/NTA - page 6
www .desatech.com 1 13097-01E 6 Exhaust fans, replaces, clothes dryers and fuel burni ng appl iances draw a ir fro m the h ouse t o operate. Y ou must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances. pROVIDING ADEQUA TE VENTILA TION The following are excerpts from National Fuel G ...
-
Desa CCL3018PTA/NTA - page 7
www .desatech.com 1 13097-01E 7 Example: Gas water heater ____________ Btu/Hr V ent-free replace + ___________ Btu/Hr T otal = ___________ Btu/Hr 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used. _________ Bt u/ Hr ( ma xi mu m th e sp ac e ca n su pp or t) _________ Bt u/ Hr ( ac tu al a mo un t of B tu ...
-
Desa CCL3018PTA/NTA - page 8
www .desatech.com 1 13097-01E 8 INST ALLA TION ? ...
-
Desa CCL3018PTA/NTA - page 9
www .desatech.com 1 13097-01E 9 W ARNING: Maintain the ? ...
-
Desa CCL3018PTA/NTA - page 10
www .desatech.com 1 13097-01E 10 Y ou must have noncombustible material(s) above the replace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombus - tible material must extend ...
-
Desa CCL3018PTA/NTA - page 11
www .desatech.com 1 13097-01E 1 1 not meet the minimum clear- ances shown, you must do one ? ...
-
Desa CCL3018PTA/NTA - page 12
www .desatech.com 1 13097-01E 12 Se e c ha rt bel ow for mi ni mum p erm an ent ue opening you must provide. Attach damper clamp so the minimum permanent ue opening will be maintained at all times. INST ALLA TION Continued INST ALLING HEA TER BASE ASSEMBL Y ? ...
-
Desa CCL3018PTA/NTA - page 13
www .desatech.com 1 13097-01E 13 INST ALLA TION Continued 7. Mark screw locati ons through holes in mount - ing brackets (see Figure 12 and 13). If install - ing in a brick-bottom replace, mark screw locations in mortar joint of bricks. 8. Remove heater base from replace. 9. Drill holes at marked locations using 3/16" drill bit. 10. Atta ...
-
Desa CCL3018PTA/NTA - page 14
www .desatech.com 1 13097-01E 14 For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce inco min g gas press ure to betwee n 11 and 14 inch es of water. If you do not reduce incoming gas pres - sure, heater regulator damage could occur. Install external regula ...
-
Desa CCL3018PTA/NTA - page 15
www .desatech.com 1 13097-01E 15 INST ALLA TION Continued - ? ...
-
Desa CCL3018PTA/NTA - page 16
www .desatech.com 1 13097-01E 16 INSTALLING LOGS - ...
-
Desa CCL3018PTA/NTA - page 17
www .desatech.com 1 13097-01E 17 INST ALLA TION Continued Figure 22 - Installing Crossover Log #4 (CCL3930PTB/NTB Shown) Middle Log (#2) Back Log (#3) Pins Crossover Log (#4) 5. Only : Locate pin and hole on the botto ...
-
Desa CCL3018PTA/NTA - page 18
www .desatech.com 1 13097-01E 18 INST ALLA TION Continued - ...
-
Desa CCL3018PTA/NTA - page 19
www .desatech.com 1 13097-01E 19 OPERATING HEATER MANUALLY-CONTROLLED MODELS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, ? ...
-
Desa CCL3018PTA/NTA - page 20
www .desatech.com 1 13097-01E 20 5. Slightly depress and turn control knob counterclockwise to the PILOT position. Press in control knob for ve (5) seconds (see Figure 30). Note: You may be running this heater for the rst time after hooking up to gas sup - ply. If so, the control knob may need to be pressed in for 30 seconds or more. This wil ...
-
Desa CCL3018PTA/NTA - page 21
www .desatech.com 1 13097-01E 21 THERMOST A T -CONTROLLED MODELS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , - ...
-
Desa CCL3018PTA/NTA - page 22
www .desatech.com 1 13097-01E 22 5. Tu rn co nt ro l kno b co unt ercl ockw ise to the PILOT position. Press in control knob for ve (5) seconds (see Figur e 32). Note: Y ou may be running this heater for the rst time after hooking up to gas sup - ply . If so, the control knob may need to be pressed in for 30 seconds or more. This will allow a ...
-
Desa CCL3018PTA/NTA - page 23
www .desatech.com 1 13097-01E 23 INSPECTING B URNERS Check pilot ame pattern and burner ame pat - terns often. pILOT FLAME p A TTERN Figure 34 sh ows a cor rec t pil ot a me pa tt ern . Figure 35 sh ow s an in co rr ec t pi lo t am e pa tt er n. Th e in co r - re ct pi lo t a me is no t to uch in g th e the rmoc oup le . Th is wi ll ...
-
Desa CCL3018PTA/NTA - page 24
www .desatech.com 1 13097-01E 24 2. Ins pect bur ner , pil ot and primar y air inlet hole s on injector holder for dust and dirt (see Figure 36). 3. Blow air through the ports/slots and holes in the burner . 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a so ...
-
Desa CCL3018PTA/NTA - page 25
www .desatech.com 1 13097-01E 25 TROUBLESHOO TING ...
-
Desa CCL3018PTA/NTA - page 26
www .desatech.com 1 13097-01E 26 TROUBLESHOO TING Continued 1. Burner orice clogged 2. Inlet gas pressure is too low 1. Manifold pressure is too low 2. Burner orice clogged 1. Burner orice is clogged or damaged 2. Damaged burner 3. Gas regulator defective 1. Not enough air 2. Gas regulator defecti ...
-
Desa CCL3018PTA/NTA - page 27
www .desatech.com 1 13097-01E 27 TROUBLESHOO TING Continued ...
-
Desa CCL3018PTA/NTA - page 28
www .desatech.com 1 13097-01E 28 OPTIONAL POSITIONING OF THERMOST A T SENSING B ULB If your log set cycles to pilot, but the room tem - perature drops to a lower than ideal comfort level before the log set ...
-
Desa CCL3018PTA/NTA - page 29
www .desatech.com 1 13097-01E 29 4. The mounting clip must be a minimum of 3" from bottom of replace to prevent crimping of capillary . Once you have decided on a location, clean the area thoroughly . Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb ...
-
Desa CCL3018PTA/NTA - page 30
www .desatech.com 1 13097-01E 30 ILL USTRA TED P ARTS BREAKDOWN ? ...
-
Desa CCL3018PTA/NTA - page 31
www .desatech.com 1 13097-01E 31 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on p ...
-
Desa CCL3018PTA/NTA - page 32
www .desatech.com 1 13097-01E 32 ILL USTRA TED P ARTS BREAKDOWN 7 23 23 23 10 8 13 14 15 4 5 1 2 1 1 12 ...
-
Desa CCL3018PTA/NTA - page 33
www .desatech.com 1 13097-01E 33 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on pag ...
-
Desa CCL3018PTA/NTA - page 34
www .desatech.com 1 13097-01E 34 ILL USTRA TED P ARTS BREAKDOWN ? ...
-
Desa CCL3018PTA/NTA - page 35
www .desatech.com 1 13097-01E 35 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on pag ...
-
Desa CCL3018PTA/NTA - page 36
www .desatech.com 1 13097-01E 36 ILL USTRA TED P ARTS BREAKDOWN ...
-
Desa CCL3018PTA/NTA - page 37
www .desatech.com 1 13097-01E 37 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manu ...
-
Desa CCL3018PTA/NTA - page 38
www .desatech.com 1 13097-01E 38 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty . p ARTS UNDER W ARRANTY Co nt act au th ori ze d dea le rs of thi s pro du ct . If th ey can ’t supp ly ori ginal repl ac eme nt part (s) , con tac t your neare st Parts Centra ...
-
Desa CCL3018PTA/NTA - page 39
www .desatech.com 1 13097-01E 39 5 Manila A ve Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 342 N. County Rd. 400 East V alparaiso, IN 46383-9704 219-462-7441 1-888-619-7060 www .portableheaterparts.com sales@portabl ...
-
Desa CCL3018PTA/NTA - page 40
Model Serial No. Date Purchased WARRANTY INFORMA TION KEEP THIS WARRANTY Always specify model and serial numbers when communicating with the factory . W e reserve the right to amend these specications at any time without notice. The only warranty applicable is our standard written warranty . W e make no other warranty , expressed or implied. LIM ...
¿Tienes una pregunta acerca de Desa CCL3018PTA/NTA?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Desa CCL3018PTA/NTA, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Desa CCL3018PTA/NTA probablemente compartirá una forma de solucionarlo.