    URL http : // www.smcworld.com FOR AIR Digital Flow Switch Large Flow Rate T ype Instruction Manual PF2A7 □ H Series ...

  • Sierra Monitor Corporation PF2A7H - page 2

    SAFETY 2 Model Indication Method 4 Name and Functions of Individual Parts 5 Installation 6 Example of Internal Circuit and Wiring 8 Setting 10 OUT1 Output Specifications 11 Function Setting 13 Other Functions 18 Specification 20 Full View with Dimensions 22 Thank you for purchasing the SMC PF2A7 □ H Series Digital Flow Switch. Please read this ma ...

  • Sierra Monitor Corporation PF2A7H - page 3

    3 2 SAFETY IMPORT ANT MESSAGES W ARNING NOTE Indicates a potentially hazardous situation which could result in death or serious injury if you do not follow instructions. Gives you helpful information. Read this manual and follow its instructions. Signal words such as WARNING and NOTE will be followed by important safety information that must be car ...

  • Sierra Monitor Corporation PF2A7H - page 4

    5 4 Unit Specification No Symbol : Unit selection function provided - M: SI units fixed Lead Wire Specification No Symbol: Lead wire with connector 3m N: None Lead wire with connector PF2A7 H - - Flow Rate Range 03: 150 to 3000 /min 06: 300 to 6000 /min 12: 600 to 12000 /min NOTE1: The revised Measurement Law of Japan does not allow use of meters o ...

  • Sierra Monitor Corporation PF2A7H - page 5

    7 6 Nominal size of screws Rc 1 36 to 38 Rc 1 ・ 1/2 48 to 50 Rc 2 48 to 50 Before you mount a flow switch, read "SAFETY" and "Installation" described in this chapter carefully to obtain safe and correct measurement. Mounting ● Use this flow switch under the specified operating pressure range. ● Use this flow switch under t ...

  • Sierra Monitor Corporation PF2A7H - page 6

    9 8 OUT1 Analog Output Load Load 24VDC + − 1 4 2 3 Brown Black White Blue Main Circuit Analog Output OUT1 + − Load Load Brown Black Blue White 1 4 2 3 24VDC Main Circuit Connector pin number Min. measured flow Max. measured flow 1 5 Analog Output [ V ] 4 20 Analog Output [ mA ] Instantaneous flow [ / min ] Output Specification When th ...

  • Sierra Monitor Corporation PF2A7H - page 7

    11 10 Note 1)    ( Display unit selection mode ) does     not exist for -M ( SI unit fixed ) type. Note 2)     ( Flow rate setting mode) does not exist when selecting during    ( Output spec. selecting mode ). ● MODE ● SE T ● SE T ● MODE ● SE T ● MODE ● SE T ● MODE ● SE T ● MODE ● SE T ● MODE ● SE T ● M ...

  • Sierra Monitor Corporation PF2A7H - page 8

    13 12 [ P ] Output mode 50ms 50ms Time Time ON OFF ON OFF note2 ) [ n ] Display Intrgrated flow 100 /pulse note2 ) Integrated flow Integrated flow ON OFF n_3 ON OFF P_3 [ n ] [ P ] Output mode 10.0 f t 3 /pulse U_1 U_2 Flow rate per pulse note1) OUT1 Output Specifications (continue) Integration switch output (oU1_1) See "Flow r ...

  • Sierra Monitor Corporation PF2A7H - page 9

    Display unit selecting mode (When Unit spec. in Model Indication is w/o "M") Unit can be selected from that of Instantaneous flow and integrated flow. The unit is changed by pressing ▲ button. It will be set up if the button is pressed. If the button is pressed instead of the button, it will change to 「 F_3 」 . ● SE T ● MODE ● ...

  • Sierra Monitor Corporation PF2A7H - page 10

    17 16 Function Setting (continue) 7. Flow rate setting mode Input set value. Input method depends on OUT1 output specification. It does not go into Flow rate setting mode when the integration pulse output is selected as OUT1. Instantaneous switch output (oU1_0) 1. Press button to input n_1(P_1) set value. 「 n_1 」 and the set value appears in tu ...

  • Sierra Monitor Corporation PF2A7H - page 11

    19 18 Error Display and T roubleshooting This function displays error location and nature. When a problem or an error occurs, take the following actions. Flow display check Check integrated flow when instantaneous flow is selected Integrated flow is displayed only during ▼ button is pressed. (Returns to instantaneous flow when releasing ▼ butto ...

  • Sierra Monitor Corporation PF2A7H - page 12

    21 20 Specification *1) With a unit selection function ( Without a unit selection function, fixed to SI unit [ /min or , m 3 , m 3 × 10 3 ]) *2) Flow rate indication is possible to be switched to normal condition of 0 ℃ /101.3kPa and standard condition of 20 ℃ /101.3kPa/65%RH (ANR) PF2A703H Flow Rate Indication/Ra nge Flow rate indication rang ...

  • Sierra Monitor Corporation PF2A7H - page 13

    22 (42.2) FLOW SWITCH 2 - G 4 - I Thred depth J A F H 55 B 40 D E C 60 Flow direction Model No. PF2A703H 55 PF2A706H PF2A712H 65 75 A 160 180 220 B 40 45 55 C 92 104 114 D 67 89 E 55 65 75 F 36 46 56 H M5 × 0.8 M6 × 1 M6 × 1 I 8 9 9 J 79 PF2A703H Rc 1, NPT 1, G 1 PF2A706H PF2A712H Rc 1 ・ 1/2, NPT 1 ・ 1/2, G 1 ・ 1/2 Rc 2, NPT 2, G 2 Thred G ...

Fabricante Sierra Monitor Corporation Categoría Switch

Los documentos del dispositivo Sierra Monitor Corporation PF2A7H que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Sierra Monitor Corporation
- manuales de instrucciones PF2A7H
- hojas de producto Sierra Monitor Corporation
- folletos informativos
- o etiquetas energéticas Sierra Monitor Corporation PF2A7H
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Sierra Monitor Corporation PF2A7H.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Sierra Monitor Corporation PF2A7H, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Sierra Monitor Corporation PF2A7H. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Sierra Monitor Corporation PF2A7H.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Sierra Monitor Corporation PF2A7H, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Sierra Monitor Corporation PF2A7H. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Sierra Monitor Corporation PF2A7H.

El manual de instrucciones completo de Sierra Monitor Corporation debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Sierra Monitor Corporation PF2A7H - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Sierra Monitor Corporation PF2A7H, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Sierra Monitor Corporation PF2A7H que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Sierra Monitor Corporation PF2A7H - que deben facilitarnos los primeros pasos durante el uso de Sierra Monitor Corporation PF2A7H
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Sierra Monitor Corporation PF2A7H
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Sierra Monitor Corporation PF2A7H en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Sierra Monitor Corporation PF2A7H?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Sierra Monitor Corporation PF2A7H, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Sierra Monitor Corporation PF2A7H probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)