    USER GUIDE AND SPECIFICATIONS NI USB-6509 This document contains info rmation about using th e National Instruments USB-6509 data acquisition (D A Q) de vice with NI-D A Qmx 8.7 and later . The NI USB-6509 is a bus-po wered 96-channel, digital input/o utput (I/O) device. The NI USB-6509 features 96 TTL/CMOS-compatible digit al I/O lines, a watchdog ...

  • National Instruments NI USB-6509 - page 2

    NI 6509 User Guide an d Specifications 2 ni.com DIO Signal Connection ....... .............. ................. .............. .............. ..16 Protecting Inductive Loads ........ .............. ................. .............. ..........17 Sinking and Sourcing Examples...................... ................. .............. ..17 Driving a Relay & ...

  • National Instruments NI USB-6509 - page 3

    © National Instruments Corporation 3 NI 6509 User Gu id e and Specifications Installing the Hardware The NI-DAQmx for USB Devices Getting Started Guide contains non-software-specific in formation about how to install USB devices. USB Cable Strain Relief The two strain relief o ptions for your USB cable are as follows: • Cable Strain Relief Groov ...

  • National Instruments NI USB-6509 - page 4

    NI 6509 User Guide an d Specifications 4 ni.com For secure desktop use, you can adhere the su pplied rubber no n-skid feet to the underside of the device, as sho wn in Figure 2. Note Do not apply t he rubber feet if you are panel mou nting the NI USB-6509 or stacking multiple NI USB-6509 devices. Figure 2. Applying Rubber Feet to the NI USB-6509 DI ...

  • National Instruments NI USB-6509 - page 5

    © National Instruments Corporation 5 NI 6509 User Gu id e and Specifications Panel Mounting T o mount the NI USB-6509 to a board or panel, complete the following steps while referring to Figure 3. Figure 3. Mounting the NI USB-6509 on a Panel Notes Do not apply the rubber feet to the NI USB-6509 when panel m ounting the device. Apply strain relief ...

  • National Instruments NI USB-6509 - page 6

    NI 6509 User Guide an d Specifications 6 ni.com Hardware Over view Figure 4 shows the key functional components of the NI USB-6 509. Figure 4. NI USB-6509 Block Diagram Figure 5 shows the back panel of the NI USB-6509. Figure 5. NI USB-6509 Back Panel Refer to the Safety G uidelines section of this document for im portant safety information. 1 I/O ...

  • National Instruments NI USB-6509 - page 7

    © National Instruments Corporation 7 NI 6509 User Gu id e and Specifications Programming Devices in Software National Instruments measurement de vices for USB are packaged with NI-DAQ driver software, an extensiv e library of functions and VIs you can call from your application so ftware, such as LabVIEW or LabWindows ™ /CVI ™ , to program all ...

  • National Instruments NI USB-6509 - page 8

    NI 6509 User Guide an d Specifications 8 ni.com Related Documentation The following documents contain information that you may fin d helpful as you use this u ser guide: • NI-DAQmx for USB Getting Started Guide —This gu ide describes how to install the NI-DA Qmx software, the D A Q de vice, and how to confirm that the de vice is operating prope ...

  • National Instruments NI USB-6509 - page 9

    © National Instruments Corporation 9 NI 6509 User Gu id e and Specifications Figure 6. Pin Assignments for the NI USB-6509 using the SH100 -100-F Refer to the Signal D escriptions section for information about the signals av ailable on this connector . +5 V P 3 .0 P0.0 P 3 .1 P0.1 P 3 .2 P0.2 P 3 . 3 P0. 3 P 3 .4 P0.4 P 3 .5 P0.5 P 3 .6 P0.6 P 3 . ...

  • National Instruments NI USB-6509 - page 10

    NI 6509 User Guide an d Specifications 10 ni.com R1005050 Pin Assignments Figure 6 shows the pin assignments for the NI USB-6509 usin g the R1005050 cable. The naming con vention for each pin is P X . Y , where X is the port (P) number , and Y i s the line number or name. Figure 7. Pin Assignments for the NI USB-6509 using the R1005050 Refer to the ...

  • National Instruments NI USB-6509 - page 11

    © National Instruments Corporation 11 N I 6509 User Guid e and Specifications Signal Descriptions Table 1 lists the signals and descriptions for all signals available on the NI USB-6509 device. Table 1. NI USB-6509 Signal Descriptions Pin Signal Name Description MSB LSB 1, 3, 5, 7, 9, 11, 13, 15 P2.<7..0> Bi-directional data lines f or port ...

  • National Instruments NI USB-6509 - page 12

    NI 6509 User Guide an d Specifications 12 ni.com Digital I/O Static DIO on NI USB-6509 Devices Y ou can use each of the NI USB-6509 DIO lines as a static digital input (DI) or digital output (DO ) line. Y ou can use static DIO lines to monitor or control digital signals. Each DIO port can be configured as a DI or DO port. All samples of static D I ...

  • National Instruments NI USB-6509 - page 13

    © National Instruments Corporation 13 N I 6509 User Guid e and Specifications conditioning solution s for digital application s requiring high current dri ve. • If you conf igure a DIO line as an input, do not dri ve the line with voltages outside of its normal operat ing range. • T reat the D A Q device as you would treat any static sensitiv ...

  • National Instruments NI USB-6509 - page 14

    NI 6509 User Guide an d Specifications 14 ni.com Figure 9. DIO Channel Configured for High DIO State with External Load Example: At power up, the device is configured for input and, by defau lt, all DIO lines are high. To pull one ch annel low, complete the following steps: 1. Install a load (R L ). Remember that the smaller the resistance, the gre ...

  • National Instruments NI USB-6509 - page 15

    © National Instruments Corporation 15 N I 6509 User Guid e and Specifications Also, make sure the pull-up resistor value is not so large that leakage current from the DIO line br ings the voltage at the re sistor below a TTL-high le vel of 2 V . Figure 10. DIO Channel Configured for Low DIO State with External Load Example: The switch is set in th ...

  • National Instruments NI USB-6509 - page 16

    NI 6509 User Guide an d Specifications 16 ni.com The NI USB -6509 has a current-sense ci rcuit on VBUS (USB p ower rail). If the output channels source more than the specif ied current, the current is limited. The two following occurrences indicate an ov ercurrent conditio n: • The inputs/outputs are d isabled • The LED on the back panel is bli ...

  • National Instruments NI USB-6509 - page 17

    © National Instruments Corporation 17 N I 6509 User Guid e and Specifications Protecting Inductive Loads When inductive loads are co nnected to outputs, a large counter-electromotive force may occu r at switching time because of the energy stored in the inductive load. These flyback voltages ca n damage the outputs and/or the power supply. T o lim ...

  • National Instruments NI USB-6509 - page 18

    NI 6509 User Guide an d Specifications 18 ni.com Figure 14. NI USB-6509 Sourcing Connection Example, <24 mA Driving a Relay >24 mA Figures 1 5 and 16 are examples of connecting the N I USB-6 509 to a relay that requires more than 24 mA of current. These examples use an additional transistor circuit. Figure 15. NI USB-6509 Sinking Connection E ...

  • National Instruments NI USB-6509 - page 19

    © National Instruments Corporation 19 N I 6509 User Guid e and Specifications Driving SSRs Figure 17 shows an example of connecting the NI U SB-6509 to a solid-state relay (SSR). Figure 17. NI USB-6509 SSR Connection Example LED Indicator The LED indicator , located on the de vice back panel, indicates de vice status. T able 2 sho ws the behavior ...

  • National Instruments NI USB-6509 - page 20

    NI 6509 User Guide an d Specifications 20 ni.com +5 V Power A vailable at I/O Connector Pins 49 and 99 su pply +5 V po wer to the I/ O connector . The po wer dra wn from these two pins shares the po we r consumption with the transceive rs. The I/O connector power has a fuse for ov ercurrent protection. This fuse is not customer replaceable. If the ...

  • National Instruments NI USB-6509 - page 21

    © National Instruments Corporation 21 N I 6509 User Guid e and Specifications Internally , the filter uses two clocks: the sample clock and the filter clock. The sample clock has a frequency of 48 MH z that corresponds to a period of 20.83 ns. The f ilter clock is generated by a counter and has a period equal to one half of the specified timing in ...

  • National Instruments NI USB-6509 - page 22

    NI 6509 User Guide an d Specifications 22 ni.com Programmable Power -Up States At power -up, the output dri ves on the NI USB-6509 are disabled. Al l lines are user-conf igurable for high-im pedance input, high ou tput, or low output. User-c onfigurable po wer-up states are useful for ensuring that the NI USB-6509 powers up in a kno wn state. T o u ...

  • National Instruments NI USB-6509 - page 23

    © National Instruments Corporation 23 N I 6509 User Guid e and Specifications Change Detection Example T able 4 sho ws a change detection example for six bits of one port. This example assumes the following line connections: • Bits 7, 6, 5, and 4 are connected to data lines from a four-bit TTL output device. The NI USB-6509 detects any change in ...

  • National Instruments NI USB-6509 - page 24

    NI 6509 User Guide an d Specifications 24 ni.com The expiration signal that indicates an expired watchdog continues to assert until the watchdog is disarmed. After the watchdo g timer expires, the NI USB-6509 ignores any writes until the watchdog timer is disarmed. Note When the watchdog timer is enabled and the com puter enters a fault condition, ...

  • National Instruments NI USB-6509 - page 25

    © National Instruments Corporation 25 N I 6509 User Guid e and Specifications Power-on state .............. ................. ......... Configured as inputs, pull-up/pull-down (select able on the back panel switch ) Pull-up/pull-down resistor..................... . 100 k Ω ±5% Data transfers ............... .............. ............ Programmed ...

  • National Instruments NI USB-6509 - page 26

    NI 6509 User Guide an d Specifications 26 ni.com The total current sinking/sourcing from one port cannot exceed 100 mA. T otal current sourced b y all DO line s simultaneously should not e xceed 215 mA for bus-po wered configuration. If more sourcing current is required, use an option al external power supply +5V power available at I/O connector (p ...

  • National Instruments NI USB-6509 - page 27

    © National Instruments Corporation 27 N I 6509 User Guid e and Specifications Safety This product is designed to meet the requirements of the follow ing standards of safety for electrical e quipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, ref ...

  • National Instruments NI USB-6509 - page 28

    NI 6509 User Guide an d Specifications 28 ni.com CE Compliance This product meets the essential re quirements of applicable European Directives, as amended for CE markin g, as follows: • 2006/95/EC; Lo w-V oltage Directiv e (safety) • 2004/108/EC; Elect romagnetic Compatibility Directive (EMC) Note Refer to the Declaration of Conformity (DoC) f ...

  • National Instruments NI USB-6509 - page 29

    © National Instruments Corporation 29 N I 6509 User Guid e and Specifications Safety Guidelines Caution Operate the hardware only as describe d in these operating instructions. The following section contains important safety infor mation that you must follow when installing and using the NI USB-6509. Do not operate the NI USB-6509 in a manner not ...

  • National Instruments NI USB-6509 - page 30

    NI 6509 User Guide an d Specifications 30 ni.com Operate the device at or belo w the Measurement Cate gory I 1 . Measurement circuits are subjected to working v oltages 2 and transient s tresses (overv oltage) from the circuit to which they are connected during measurement or test. Measurement cat egories establish standard impulse withstand voltag ...

  • National Instruments NI USB-6509 - page 31

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e informat ion about Nationa l Instruments trademarks. Other product and compan y names mentioned herein are t rademarks or trade names of their respective companie s. For patent s covering Na ...

Fabricante National Instruments Categoría Computer Drive

Los documentos del dispositivo National Instruments NI USB-6509 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos National Instruments
- manuales de instrucciones NI USB-6509
- hojas de producto National Instruments
- folletos informativos
- o etiquetas energéticas National Instruments NI USB-6509
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones National Instruments NI USB-6509.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje National Instruments NI USB-6509, instrucciones de servicio, instrucciones cortas o instrucciones de usuario National Instruments NI USB-6509. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto National Instruments NI USB-6509.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo National Instruments NI USB-6509, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar National Instruments NI USB-6509. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de National Instruments NI USB-6509.

El manual de instrucciones completo de National Instruments debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual National Instruments NI USB-6509 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice National Instruments NI USB-6509, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de National Instruments NI USB-6509 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo National Instruments NI USB-6509 - que deben facilitarnos los primeros pasos durante el uso de National Instruments NI USB-6509
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con National Instruments NI USB-6509
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de National Instruments NI USB-6509 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de National Instruments NI USB-6509?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con National Instruments NI USB-6509, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con National Instruments NI USB-6509 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)