    6 7 20 606 804 US (04. 1 1 ) AL WARNING : Improper installation, adjustment , alteration , service or maint enance can c ause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier . Upon completion of the installation, these instructions should be ...

  • AquaStar 125HX - page 2

    2 6 720 606 804 WARNING : Improper installation, adjustment , alterat ion, service or maint enance c an c ause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier . Upon completion of the installation, these instructions should be handed to the u ...

  • AquaStar 125HX - page 3

    3 6 720 606 804 Principle of Operation: When a hot water faucet is opened, the water flow through the heater causes the gas valve to open. At the same time the hydro-generator activates the electronics which sends a spark to the pilot. The flame sensor confirms the pilot has been lighted and allows the first two burners to come on. The flame sensor ...

  • AquaStar 125HX - page 4

    4 6 720 606 804 M I N I M U M I N S T ALLA TI ON C LE AR ANC E S FR O M C O M B U S TI B LE AN D NO N CO M B U S TI B LE MA TE R IALS F O R AL C O VE O R C L O S ET I N S T ALLA TI O NS FRONT VIEW SIDE VIEW M ODE L 1 25HX MO DEL 125 HX TO P (A) 12" FRONT (B) 4" BACK 0" SIDES 4" FLOOR (C) 12" VENT D IAM ET ER 5" ...

  • AquaStar 125HX - page 5

    5 6 720 606 804 G E NE R AL R U LE S T O FOLL OW FOR SAF E O PE RA TIO N 1. Y ou should follow these instructions when you install your heater . In the United States : The installation must conform with local codes or , in the absence of local codes , the National Fuel Gas Code ANSI Z223. 1 / N F P A 54. In Canada: The Installation should conform w ...

  • AquaStar 125HX - page 6

    6 6 720 606 804 WARNING: Flammable materials, gasoline, pressurized containers, or any other items or articles that are pot entially fire hazards must NOT be placed on or adjacent t o t he heat er . The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids. COMBUSTION AIR REQUIREMENTS T he 1 ...

  • AquaStar 125HX - page 7

    7 6 720 606 804 VENTING V ent pipe connect ion. WARNING: Do not reduce the vent pipe size. See Fig. 4 for high altitude installations The heater must be vented to the outside following all local ordinances and specifications for installing a gas appliance vent or chimney . The heater must be located as close as practicable to a vertically rising ch ...

  • AquaStar 125HX - page 8

    8 6 720 606 804 T o check t he draft : Close all doors and windows to the outside. T urn on all appliances that force air out of the building. These include all exhaust/ventilation fans, furnaces, clothes dryers, wood burning stoves, etc. Open all doors between the 1 25 HX and these other appliances. With the control knob set fully clockwise and st ...

  • AquaStar 125HX - page 9

    9 6 720 606 804 GAS CONNECTIONS NOTE: T he 1 25 HX is supplied wit h a gas pressure regulator that must be installed on the heater before attaching the gas supply line. See fig. 5. Failure to install the gas regulator as shown in figure 5 will be a violation of CSA cert ification of t he unit . T he regulat or supplied with the heater is preset for ...

  • AquaStar 125HX - page 10

    10 6 720 606 804 Nominal Iron P ipe Black Iron Pipe Size , Length of Pipe, Feet Inches 10 20 30 40 50 60 70 80 90 100 125 150 1/2 275 189 152 129 114 103 96 89 83 78 69 63 3/4 567 693 315 267 237 217 196 185 173 162 146 132 1 107 732 590 504 448 409 378 346 322 307 275 252 1 1/4 220 149 121 103 913 834 771 724 677 630 567 511 1 1/2 330 229 185 155 ...

  • AquaStar 125HX - page 11

    11 6 720 606 804 OPER A TIN G INST R U C T IONS Before proceeding with the operation of the heater make sure that the system is filled with water . Open the cold water inlet supply to the heater fully . Open a hot water faucet to permit the water to fill the heater and the piping and to eliminate the air trapped in the system Close the hot water fa ...

  • AquaStar 125HX - page 12

    12 6 720 606 804 The position you select on the temperature adjustment knob will depend on the temperature of the incoming water (50 °F is average in the U.S.). In warm weather regions where the incoming cold water is generally warmer, or during the hot weather months in some other areas a midway setting on the temperature adjustment knob would pr ...

  • AquaStar 125HX - page 13

    13 6 720 606 804 Fig. 1 0 - Charact eristic Pilot Flame (Pilot assembly shown without pilot hood) MAINTENANCE AND SERVICE RE VIEW MAINT E N ANCE T ABLE ON TH E BA CK OF THIS MANUAL. Approximately once a year, the 1 25 HX should be chec ked and cleaned. T o remove the front cover, first remove the incandescent particle tray , then pull off the tempe ...

  • AquaStar 125HX - page 14

    14 6 720 606 804 Problems are stated in upper case, bold face. Most common causes for the problems follow in order of likelihood. The suggested solutions require that the cover be taken off. T o do this, remove incandescent particle tray , pull off the temperature adjustment knob and unscrew and remove the plastic collar . Pull main cover out towar ...

  • AquaStar 125HX - page 15

    15 6 720 606 804 Fig. 1 3 - Elect rical wiring diagram 5 . Flue gas safety device tripped V entilate the room and operate the appliance 1 0 minutes later . Provide more combustion air to the room and/or inspect and correct venting system. Afterwards, if it happens again, contact your service person. WA TE R I S TOO HOT 1 . T emperat ure S election ...

  • AquaStar 125HX - page 16

    16 6 720 606 804 HO T WA TE R TE MP ERA TU RE F L U C TUA TE S / U N IT DEAC TIV A TE D 1 . Unbalanced pressure in waterlines The added restriction caused by the 1 25 HX in the hot water system can result in uneven pressures between the cold and the hot. In such cases when mixing cold water at the tap, the lower hot water pressure may be overpowere ...

  • AquaStar 125HX - page 17

    17 6 720 606 804 Fig. 1 4 - Diagram of 1 25 HX 1 . Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. LED failure indicator 7 . on/off switch 8. LED operation indicator 9. W ater valve 1 0. T emperature adjustment selector 1 1 . Gas inlet gas pressure test nipple 1 2. Hose 3 1 4 10 ...

  • AquaStar 125HX - page 18

    18 6 720 606 804 Fig. 1 5 - I NTE RI OR C OM PON E NTS DIAGR AM AN D P ARTS LI ST ...

  • AquaStar 125HX - page 19

    19 6 720 606 804 Fig. 1 5 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LI ST 1 25 HX 1 Cover 8 705 421 752 2 Tem perature adjustm ent knob 8 702 000 111 3 Tem perature adjustm ent collar 8 700 403 008 4 Draft diver ter 8 705 505 354 5 Heat exchanger 8 705 406 235 7 Main burner 8 708 120 298 NG 7 Main burner 8 708 120 296 LP 8 Burner ass embly w asher 8 ...

  • AquaStar 125HX - page 20

    20 6 720 606 804 Fig . 1 6 - Flow chart of 1 25 HX ...

  • AquaStar 125HX - page 21

    21 6 720 606 804 NO TE: the water heater must be free of damaging scale deposits and not subject to gas pressures greater than those shown on the rating plate, which must not be altered, defaced or removed . How to Make a Claim Any claim for warranty parts should be made to your local dealer , distributor or to C EC . If C EC , please cont act the ...

  • AquaStar 125HX - page 22

    22 6 720 606 804 ...

  • AquaStar 125HX - page 23

    23 6 720 606 804 ...

  • AquaStar 125HX - page 24

    VU L C ANO T ermodomésticos S.A . Estrada de Cacia 380 1 - 856 Av ei ro - P ORTU GAL Recycled paper © 2004 Controlled Energy C orporation, W aitsfield, VT all rights reserved Replacement Parts available from North American Distributor CONTROLL E D E NE RG Y COR P . 340 Mad River Park Waitsfield, Vermont 0 56 7 3 Phone 8 00-642-3 1 1 1 Fax (802) 4 ...

Fabricante AquaStar Categoría Water Heater

Los documentos del dispositivo AquaStar 125HX que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos AquaStar
- manuales de instrucciones 125HX
- hojas de producto AquaStar
- folletos informativos
- o etiquetas energéticas AquaStar 125HX
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones AquaStar 125HX.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje AquaStar 125HX, instrucciones de servicio, instrucciones cortas o instrucciones de usuario AquaStar 125HX. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto AquaStar 125HX.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo AquaStar 125HX, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar AquaStar 125HX. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de AquaStar 125HX.

El manual de instrucciones completo de AquaStar debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual AquaStar 125HX - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice AquaStar 125HX, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de AquaStar 125HX que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo AquaStar 125HX - que deben facilitarnos los primeros pasos durante el uso de AquaStar 125HX
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con AquaStar 125HX
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de AquaStar 125HX en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de AquaStar 125HX?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con AquaStar 125HX, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con AquaStar 125HX probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)