User Guide Cable Cubby ® 200 Architectur al Connectivity Cable Access Enclosur e 68-1557-01 Rev . A 10 12 ...
-
Extron electronic 200 - page 2
Safety Instructions • English W ARNING : This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated danger ous voltage within the product’ s enclosure that may pr esent a risk of electric shock. A TTENTION: This symbol, , when used on the pr oduct, is intended to alert the user of important operating a ...
-
Extron electronic 200 - page 3
Conventions Used in this Guide The following notifications are used: CAUTION: A caution indicates a situation that may result in minor injury . A TTENTION: Attention indicates a situation that may damage or destroy the pr oduct or associated equipment. NOTE: A note draws attention to important information. Specifications Availability: Product speci ...
-
Extron electronic 200 - page 4
...
-
Extron electronic 200 - page 5
v Cable Cubby 200 • Contents Contents Introduction ............................................................ 1 Overview ............................................................ 1 Cable Cubby 200 Features ................................ 1 Kit Contents ........................................................... 2 Included Parts ............ ...
-
Extron electronic 200 - page 6
Cable Cubby 200 • Introduction 1 Intr oduction Overview The Extron Cable Cubby 200 is a furniture-mounted, ar chitectural solution that provides inconspicuous cable access and connection points. When cables are not in use, they can be stored out of the way while r emaining connected to the presentation system. Lift the lid to access the AAPs and ...
-
Extron electronic 200 - page 7
Cable Cubby 200 • Kit Contents 2 Kit Contents Included Parts Image Part Quantity Cable Cubby 200 enclosure 1 Cable pass-through AAPs 2 Cable stand-offs 4 Mounting screws (6-32 x 3/4 inch) 4 Grommet and hole plug kit 1 ...
-
Extron electronic 200 - page 8
Cable Cubby 200 • Before Getting Started 3 Befor e Getting Started This section describes important information about the Cable Cubby 200 and planning considerations for installation. T opics in this section include: • About the Cable Cubby 200 • Planning • T ools and Equipment Required for Installation About the Cable Cubby 200 Fi ...
-
Extron electronic 200 - page 9
Cable Cubby 200 • Before Getting Started 4 Planning Determine the best location for the enclosure. Befor e making any cuts : • Ensure that the location wher e the Cable Cubby is to be installed is convenient for as many users as possible. • Ensure that the edge on which the lid opens is oriented corr ectly . • Ensure that ther e is ...
-
Extron electronic 200 - page 10
Cable Cubby 200 • Installation 5 Installation This section provides information for an experienced installer to set up and install the Cable Cubby 200. Before starting, decide wher e to install the Cable Cubby , verify that all included parts are accounted for , and gather the necessary equipment for installation. CAUTION: Risk of injury to the e ...
-
Extron electronic 200 - page 11
Cable Cubby 200 • Installation 6 1. Prepar e the Routing T emplate NOTE: Save and reuse the metal r outing template for installing additional Cable Cubby 200 models. a. Cut 1/2 inch x 4 inch strips of soft, finished lumber to a length that is long enough to span the edges of the mounting surface. b. Place the template over the strips so that the ...
-
Extron electronic 200 - page 12
Cable Cubby 200 • Installation 7 1. Plan for AAPs TIP: T ypical installations consist of a VGA (large hole), an audio (small hole), and a network (medium hole) cable. In a non-standard installation, match the diameter of the cable to the size of the hole that best applies. NOTE: Pass-through AAPs can also be replaced by optional passive AAPs for ...
-
Extron electronic 200 - page 13
Cable Cubby 200 • Installation 8 3. Install Any Necessary Split Grommets and Hole Plugs a. Slip the appropriate split grommet over each cable with the flange of the grommet towar d the connector that will be accessible inside the Cable Cubby . Snap the grommets into the channels. b. If necessary , snap the included hole plugs into unused holes. 4 ...
-
Extron electronic 200 - page 14
Cable Cubby 200 • Installation 9 Secu re cables w/ zip ties to holes in r ear of Cable Cubby . Power Co rd Connect to AV Device or System 1. T est the Fit a. Remove the plastic strips on finished surfaces of the Cable Cubby . A TTENTION: Potential damage to property . Do no use isopropyl alcohol or other solvents to clean the Cable Cubby . Strong ...
-
Extron electronic 200 - page 15
Cable Cubby 200 • Reference Information 10 Refer ence Information This section provides part numbers for the Cable Cubby 200 and r elated products. Visit the Extron website, www .extron.com , for more details and part numbers. T opics in this section include: • Enclosure Part Numbers • Included Accessories Part Numbers • Routing T ...
-
Extron electronic 200 - page 16
Cable Cubby 200 • Reference Information 11 Cable Pass-through AAPs (see figur e 2 ) Part Numbers Cable pass-through (right) 70-267-01 Cable pass-through (left) 70-270-01 Grommet and Plug Kit Part Numbers Grommet and hole plug kit 70-387-01 Routing T emplate Part Numbers The Cable Cubby 200 metal routing template (see figur e 3 ) is the only prefe ...
-
Extron electronic 200 - page 17
Cable Cubby 200 • Reference Information 12 T op Plate Dimensions If you choose not to use the Extron metal r outing template, the paper cut-out template will help you properly pr epare the mounting surface (see figur e 4 ). The cutout template is not to scale and is for refer ence only . For full size paper templates, visit the Extron website ( w ...
-
Extron electronic 200 - page 18
Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only) Extron USA - W est Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 F AX +1.919.850.1001 F AX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.4050 F AX Extron Asia +800.7339.8766 (Inside Asia Only) +65.6383.4400 +65.6383.4664 F AX Extron Japan ...
¿Tienes una pregunta acerca de Extron electronic 200?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Extron electronic 200, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Extron electronic 200 probablemente compartirá una forma de solucionarlo.