Manual de instrucciones York MLCA-MLHA-07-24

22 de páginas 2.62 mb
Descargar

Pasar a la página of 22

Summary
  • York MLCA-MLHA-07-24 - page 1

    Installation & Owner ’ s Manual MODELS MLCA-MLHA 07-24 MLCB-MLHB 07-24 MACC-MAHC 07-24 MINISPLIT HIGH W ALL AIR CONDITIONER EN035M80013-000 The units comply with one or more of the following marks - see unit for details. J199.pmd 31/03/2005, 9:52 PM 1 ...

  • York MLCA-MLHA-07-24 - page 2

    CONTENTS Safety Precautions ..................................................... 3 Part Names ................................................................. 4 Manual Operation ....................................................... 5 How the air conditioner works .................................. 5 Optimal operation ........................... ...

  • York MLCA-MLHA-07-24 - page 3

    3 ENGLISH EN EXTENDED P ARTS 1. Refrigarant Pipe 2. Pipe i nsulation material (Polyethylene foam 9 mm thick) 3. Vinyl tape 4. Putty REQUIRED TOOLS 1. Screw driver 9. Manifold gauge 2. Hexagonal wrench 10. Gas leak detector 3. T orque wrench 11 . V acuum pump 4. Spanner 12. Pipe clamp 5. Reamer 13. Pipe cutter 6. Hole core drill 14. Flare tool set 7 ...

  • York MLCA-MLHA-07-24 - page 4

    4 ENGLISH (C ) T E M P A U T O C O O L D R Y H E A T F A N H I G H M E D L O W M O D E F A N S P E E D T I M E R O N S L E E P O N /O F F T IM E R O F F A IR D IR E C T IO N R E S ET LO CK S E T T E M P E R A T U R E S W I N G LE D D ISP L A Y TU R BO 9 5 4 7 2 1 3 8 6 12 13 10 11 P ART NAMES CAUTIONS 1. If air conditioner is used outside of the ab ...

  • York MLCA-MLHA-07-24 - page 5

    5 ENGLISH EN MANUAL OPERA TION 1 Open and lift the front panel up to an angle at which it remains fixed with a clicking sound. 2 Press the button until the AUTO indicator is lit, the unit will work in forced AUTO mode. 3 Close the panel firmly to its original position. • Once you push the manual button, the operation mode is shifted in an order a ...

  • York MLCA-MLHA-07-24 - page 6

    6 ENGLISH OPTIMAL OPERA TION T o achieve optimal performance, Please note the following: • Adjust the air flow direction correctly so that it is not directed on people. • Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels. • Close doors and windows on COOL or HEA T modes, or per ...

  • York MLCA-MLHA-07-24 - page 7

    7 ENGLISH EN OUTDOOR UNIT PICTURES 540 525 225 75 404 88 700 458 5 35 250 88 33 60 261 60 82 80 540 527 245 5 420 128 780 48 10 45 548 115 90 266 272 298 285 290 530 110 62 590 750 MLDA-MLJA 07-09, MLDB-MLJB 07-09, MADC-MAJC 07 MLDA-MLJA 12-18, MLDB-MLJB 12, MADC-MAJC 09-12 MLDA-MLJA 24, MLDB-MLJB 24, MADC-MAJC 18-24 MLDB-MLJB 18 335 125 560.1 141. ...

  • York MLCA-MLHA-07-24 - page 8

    8 ENGLISH ø 65 mm Number Name of part Q’ty 1 Installation plate 1 2 Clip anchor 8 3 Self-tapping screw A ST3.9X25 8 Connecting pipe assembly P ARTS INST ALLA TION NOTES INDOOR UNIT INST ALLA TION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • York MLCA-MLHA-07-24 - page 9

    9 ENGLISH EN • Be careful when handling the sharp edge of the mounting plate. ■ Wiring • This indoor unit is ready for connection to the outdoor unit. • Never modify the unit by removing any of the safety guards or by passing any of the safety interlock swithces. • Connect the interconnecting cable correctly and connect the connecting cab ...

  • York MLCA-MLHA-07-24 - page 10

    10 ENGLISH ■ Indoor Unit Fixing • Thread the indoor unit piping and cable through the hole. • Hang the top of the unit onto the upper ridge of them in mounting plate. • Make sure that the unit is correctly hung in place by sliding it to the left, then to the right. • Press the bottom left and bottom right hand corners of the unit against ...

  • York MLCA-MLHA-07-24 - page 11

    11 ENGLISH EN T o this effect, when the piping has been evacuated, close the pressure gauge tap, note the value on the gauge, then wait for 15 minutes. If the needle moves, there is a leak in the system. Make the necessary adjustments or repairs and repeat this procedure until the needle no longer moves. - Open the service valves and top up the ref ...

  • York MLCA-MLHA-07-24 - page 12

    12 ENGLISH ■ Wiring Prepare the power source for exclusive with the air conditioner . The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation. Remark: All the wiring must be based on the wiring nameplate which is shown on the model. • Perform the wiring with sufficient ...

  • York MLCA-MLHA-07-24 - page 13

    13 ENGLISH EN ■ Wiring Connection Models : 07-18 Indoor Outdoor Cooling only type Cooling & heating type Cooling only type Cooling & heating type Models : 24 Indoor Outdoor 1 2(N) 3 4 1 2(N) 3 4 1 2(N) 1 2(N) 3 4 T e S 1 2 (N) Cooling & heating type Cord clamp 1 2(N) 3 4 5 6 7 8 Terminal block of Outdoor unit 1 2(N) S L N T erminal bl ...

  • York MLCA-MLHA-07-24 - page 14

    14 ENGLISH ■ Electrical Work ■ Defrosting operation (A vailable for heating only) 1. Condition to start defrosting: Units will switch to defrosting mode when either of the following conditions is met. a . Unit has been running under T3<0 º C for 40 minutes and T3<-3 º C for 3 minutes. b . Unit has been running at high temperature protec ...

  • York MLCA-MLHA-07-24 - page 15

    15 ENGLISH EN MAINTENANCE ■ Cleaning the air filter A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks. 1. Lift the indoor unit panel up to an angle until it stops with a clicking sound. 2. T ake hold of the handle of the air filter and lift it up slightly to take it out from the filter ho ...

  • York MLCA-MLHA-07-24 - page 16

    16 ENGLISH OPERA TION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner . Compressor protection • The compressor can ’ t restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) • The unit is designed not to blow cold air on HEA T mode, when the indoor heat exchanger ...

  • York MLCA-MLHA-07-24 - page 17

    17 ENGLISH EN TROUBLE SHOOTING GUIDE Problem Probable cause Remedy A. The air conditioner does not run. 1. Power failure. 1. Wait for power resume. 2. Fuse blown or circuit breaker 2. Replace the fuse or reset the open. breaker . 3. V oltage is too low . 3. Find the cause and fix it. 4. Faulty contactor or relay . 4. Replace the faulty component. 5 ...

  • York MLCA-MLHA-07-24 - page 18

    18 ENGLISH TECHNICAL SPECIFICA TION T echnical Specifications : Master Gold “ R22 ” - 50 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant T ype Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input Power W Running Current A Height mm Dimensi ...

  • York MLCA-MLHA-07-24 - page 19

    19 ENGLISH EN 111 1 1 TECHNICAL SPECIFICA TION T echnical Specifications : Master Gold “ R22 ” - 60 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant T ype Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input Power W Running Current A Height ...

  • York MLCA-MLHA-07-24 - page 20

    20 ENGLISH TECHNICAL SPECIFICA TION T echnical Specifications : Master Gold “ R407C ” - 50 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant T ype Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input Power W Running Current A Height mm Dimen ...

  • York MLCA-MLHA-07-24 - page 21

    21 ENGLISH EN TECHNICAL SPECIFICA TION T echnical Specifications : Master Gold “ R410A ” - 50 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant T ype Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input Power W Running Current A Height mm Di ...

  • York MLCA-MLHA-07-24 - page 22

    DECLARACI Ó N DE CONFORMIDAD CM Choi Shipping Manager The product complies with the harmonized European safety standards and harmonized EMC standards listed above. We have internal production control system that ensures compliance between the manufacturer products and the technical documentation. The product is CE mark. We declare under our sold r ...

Fabricante York Categoría Air Conditioner

Los documentos del dispositivo York MLCA-MLHA-07-24 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos York
- manuales de instrucciones MLCA-MLHA-07-24
- hojas de producto York
- folletos informativos
- o etiquetas energéticas York MLCA-MLHA-07-24
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones York MLCA-MLHA-07-24.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje York MLCA-MLHA-07-24, instrucciones de servicio, instrucciones cortas o instrucciones de usuario York MLCA-MLHA-07-24. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto York MLCA-MLHA-07-24.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo York MLCA-MLHA-07-24, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar York MLCA-MLHA-07-24. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de York MLCA-MLHA-07-24.

El manual de instrucciones completo de York debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual York MLCA-MLHA-07-24 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice York MLCA-MLHA-07-24, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de York MLCA-MLHA-07-24 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo York MLCA-MLHA-07-24 - que deben facilitarnos los primeros pasos durante el uso de York MLCA-MLHA-07-24
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con York MLCA-MLHA-07-24
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de York MLCA-MLHA-07-24 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de York MLCA-MLHA-07-24?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con York MLCA-MLHA-07-24, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con York MLCA-MLHA-07-24 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)