  • Milan Technology MIL-S8001TG - page 1

    8-Port 10/100/1000 + 1 MiniGBIC Gigabit Ethernet Smart Workgroup Switch MIL-S800 1TG User Guide ...

  • Milan Technology MIL-S8001TG - page 2

    Regulatory Approval - FCC Class A - UL 1950 - CSA C22.2 No. 950 - EN60950 - CE - EN55022 Class A - EN55024 Canadian EMI Notice This Class A digital appar atus meets all the requirements of the Can adian Interference-Causing Equipment Regulations. Cet appareil numerique de la classe A respecte toutes les ex igences du Reglement sur le materiel bro u ...

  • Milan Technology MIL-S8001TG - page 3

    Table of Contents 1. Introduction Features Software Fea tures Package Cont ents Ethernet S witching Technology Managemen t Methods 2. Hardware Description Front Pane l LED Indicat ors Rear Panel Desktop Installat ion Attaching Rub ber Feet Power On 3. Network Applicat ion Small W orkgroup Segment B ridge 4. Console Management Connecting a T erminal ...

  • Milan Technology MIL-S8001TG - page 4

    4-4. Broadc ast Storm Suppression 4-5. Restore to Default 4-6. Reset S ystem 5. Troubleshoo ting 6. Technical Specifications ...

  • Milan Technology MIL-S8001TG - page 5

    1 1. Introduction The MIL-S80 01TG switch is a multi-port switch that can be used to build high-perform ance switched workgroup n etworks. This switch is a store-and-forward d evice that offe rs low latency for high-spe ed networking. The switch is targeted at workgroup, depa rtment or backbone computing environme nts. Figure 1-1. T he MIL-S 8001TG ...

  • Milan Technology MIL-S8001TG - page 6

    2 Features  Conforms to I EEE 802.3 1 0BASE-T,I EEE 802.3u 100BAS E-TX,IEEE 802.3ab 1000BA SE-T,IEEE 802.3z gigabit f iber and IEEE 802 .3x  8 x 10/100/10 00 Base-TX RJ-45 ports  1 MINI GB IC socket for MINI GBIC Fibe r transceiver  Auto-MDIX on all ports and N-Wa y Auto-Negotiation  16 Gbps bac k-plane  Quality of se rvice (QoS) ...

  • Milan Technology MIL-S8001TG - page 7

    3 Softw are Featur es VLAN Port Based VLA N, support up to 8 group s 4K IEEE802 .1Q Tag VLAN QOS 2 Types of quality of service: 1.Port bas ed priority. 2. 80 2.1p/TOS priority tag Priority Queue System pro vide 4 queues for High and Low priority. Queue Ratio: High:Middle:Low:Lowest =8:4:2:1 Broadcas t Storm filter Disable or Enab le Package Content ...

  • Milan Technology MIL-S8001TG - page 8

    4 Ethernet Sw itching Tech nolog y Ethernet Switching Technology dramatica lly boosted the total bandwidth of a network, elim inated congestion problem s inherent with CSMA/CD (Carrier Sense multiple a ccess with Collision Dete ction) protocol, and greatly reduced unnecessa ry transmissions. This revolutionized networking. First, by allowing two-wa ...

  • Milan Technology MIL-S8001TG - page 9

    5 Manageme nt Metho ds The MIL-S80 01TG switch series supports Conso le Management method s Console Management is done through the RS-232 Console Port. Managing the switch in this m ethod requires a direct connection between a PC and the switch. ...

  • Milan Technology MIL-S8001TG - page 10

    6 2. Hardwar e Description Front Panel The Front Pane l of the MIL-S8001TG switch consists of eight 10/100/1000Bas e-TX RJ-45 ports, one MI NI GBIC slot, one LED-Indicato r for Power, three LED-Indicators (100/100 0, LNK/ACT, FDX/COL) for each UTP port, and two LE D-Indicators (LNK/ACT ) for the Mini-GBIC slot. Figure 2-1. F ront pane l for MIL-S80 ...

  • Milan Technology MIL-S8001TG - page 11

    7 ...

  • Milan Technology MIL-S8001TG - page 12

    8 LED Indicat ors The LED In dicators give real-time inf ormation of systematic ope ration status. The follo wing table provides description s of LED statuses and their meanin g. Figure 2-2. L ED Indic ators LED Status Color Description Power On Green Power On On Green The port is ope rating at the speed of 1000Mbps. On Orange The port is ope ratin ...

  • Milan Technology MIL-S8001TG - page 13

    9 On Orange The port is ope rating in Full-duplex mode. Blinks Orange Collision of Packets is occurring in the port. FDX /COL Off The port is ope rating in Half-duple x mode o r no device attached. LNK (MINI GBIC) On Green The port is su ccessfully connecting with the de vice. ACT (MINI GBIC) Blinks Green The port is rec eiving or transmitting data ...

  • Milan Technology MIL-S8001TG - page 14

    1 0 Rear Panel The 3-pronged power plug and console port are located at the rear panel of th e MIL-S8001TG as shown in Figure 2 -3. The switch will work with AC i n the range 100-24 0V AC, 50-60Hz. Figure 2-3. T he Rear P anel of MIL- S8001TG switch Desktop I nstalla tion Set the switch o n a sufficiently large flat space with a power outlet nea rb ...

  • Milan Technology MIL-S8001TG - page 15

    11 Power On Connect the power cord to the power socke t on the rear panel of the switch. Connect the other end of the cord to an appropriate power outlet. The inte rnal power supp ly in the switch works with AC in the voltage range of 100-240VAC and frequen cy 50~60Hz. Check the power ind icator on the front pa nel to see if power is properly suppl ...

  • Milan Technology MIL-S8001TG - page 16

    1 2 3. Netw ork Application This section pro vides you a f ew samples of net work topology in witch the S witch is used. In general, the 8 Gigabit Copper with o ne MI NI GBI C Smart switch is designed as a segment switch. That is, with its address table (4000 MAC address) and high pe rformance, it is ideal for in terconnecting net working segments. ...

  • Milan Technology MIL-S8001TG - page 17

    13 Segment Bri dge For ente rprise networks where l arge data broadcasts are constant ly processed, this switch is an ideal solu tion for departme nt users to c onnect to the corpo rate backbone . In the illustration below, t wo Ethernet switches with PCs, print server, and local server attac hed, are both conn ect to the switch. All the devices in ...

  • Milan Technology MIL-S8001TG - page 18

    1 4 4. Console Managem ent Connecti ng a Ter minal or PC to the Co nsole P ort Console mana gement involves the administ ration of the switch via a direct connection to the RS-232 console port. This port is a female DB-9 conne ctor. From the ma in menu of the console program , the user has access t o manage the funct ions of the switch. Use the sup ...

  • Milan Technology MIL-S8001TG - page 19

    15 After the c onnection betw een the Switch and PC is finish ed, t urn on the PC and run a termina l emulation program or Hyper Terminal and conf igure its communica tion parameters to match t he follow in g default chara cteristics of the conso le port: Baud Rate: 9600 bps Data Bits: 8 Parit y : none Stop Bit: 1 Flow Control: None Figure 4-1. T h ...

  • Milan Technology MIL-S8001TG - page 20

    1 6 4-1. Mai n Menu There are five ite ms for selection as follows. VLAN Mode: Co nfigure the VLAN functio n. QOS Control: Configure the QoS function. Broadcas t Storm Suppres sion : Enable or disab le Broadcast Storm filtering function. Restore to De fault: Set the system to the default value settings. Reset System: Rest art the system. ...

  • Milan Technology MIL-S8001TG - page 21

    17 4-2. VL AN Mode Select VLA N Mode to access the VLA N configuration menu. The system supports two VL AN modes – 802.1Q a nd Port-Based VLAN. At the Main Menu command p rompt, type “ v ” or “ V ” to enter the VLAN Mode configuratio n interface. Previous Menu: E nter “ q ” or “ Q ” and the comma nd prompt to exit the curren t int ...

  • Milan Technology MIL-S8001TG - page 22

    1 8 4-2-1. 802.1Q VLAN Configuration After selectin g VLAN mode from the Main Menu, enter the 802.1Q VL AN configuratio n interface by entering " 8 " at the command prompt. Previous Menu: E nter “ q ” or “ Q ” and the comma nd prompt to exit the curren t interface. ...

  • Milan Technology MIL-S8001TG - page 23

    19 4-2-1-1. Enab ling 80 2.1Q VL AN Prior to configuring 802.1Q VLAN, the 802.1Q VLAN function must be e nabled . Enter “ e ” or “ E ” at the 80 2.1Q VLAN menu comm and prompt to enable the 802.1Q VLA N function. To disable the 80 2.1Q VLAN function, en ter “ d ” or “ D ” at the command prompt. Previous Menu: E nter “ q ” or “ ...

  • Milan Technology MIL-S8001TG - page 24

    2 0 4-2-1-2. VL AN Confi guration The Port VI D can be configured for ea ch port. Enter “ v ” or “ V ” at the 802.1Q VLAN comma nd prompt to the access t he VLAN configuration interface. Enter the port numb er to be configured. Next, en ter the PVID numbe r to be assigned to the se lected port. The PVID range is f rom 1 to 512. Previous Men ...

  • Milan Technology MIL-S8001TG - page 25

    21 4-2-1-3. Creat e VL AN Group Enter “ c ” or “ C ” at the comm and prompt to access the Create VLAN Group configuratio n interface. VLAN group ID: En ter the VLAN Group ID a t the prompt. Add VLAN group mem ber: Enter “ m ” or “ M ” at the command prompt t o add the port to the VLAN group, use the comma nd “ +port number ” to ...

  • Milan Technology MIL-S8001TG - page 26

    2 2 Tag/Untagged S etting : Enter “ t ” or “ T ” at the VLAN Configure command prompt to ente r Tag/Untagged Setting co nfiguration in terface. Use the command “ +port number ” to set the port as the T agged status. Use the command “ -port numbe r ” to set the port to the Untagged status. After configuratio n, enter command “ q ? ...

  • Milan Technology MIL-S8001TG - page 27

    23 4-2-1-4. VL AN Statu s VLAN Group Informa tion can be viewed by entering “ s ” or “ S ” a t the 8 02.1Q VLAN menu command prom pt to ac cess the VLA N Statu s int erface. En ter t he VLAN group ID to display the VLAN status. Previous Menu: E nter “ q ” or “ Q ” and the comma nd prompt to exit the curren t interface. ...

  • Milan Technology MIL-S8001TG - page 28

    2 4 4-2-2. Port-Based VLA N Configuration At the VLAN mo de menu interface, ente r “ p ” or “ P ” at the command prompt to access the Port-Based VLAN mode conf iguration interface. Previous Menu: E nter “ q ” or “ Q ” and the comma nd prompt to exit the curren t interface. ...

  • Milan Technology MIL-S8001TG - page 29

    25 4-2-2-1. Port- Based VL AN Group Config uration A maximum of 8 VLAN groups can b e configured. The default V LAN group is VLAN 1. 1. Enter the group numb er to configure a VLA N group. For example: enter “ 1 ” for VLA N group 1. 2. To add a port to a V LAN group, use the comma nd “ +port number ” to add the port or enter “ +A ” to ad ...

  • Milan Technology MIL-S8001TG - page 30

    2 6 4-3. QoS C ontrol Select QoS Control to access the QoS configuration menu. The s ystem supports two m ethods of QoS control – Po rt-Based and 802.1P/TOS. From the Ma in Menu, enter " q " or " Q " to se lect QoS Control to enable or disable the Qos function and set the high/lo w queue priority ratio. Port-Based E nable: Ent ...

  • Milan Technology MIL-S8001TG - page 31

    27 Priority ID Map: T o configure the QoS co ntrol high/low weight setting, en ter “ m ” or “ M ” at the command prompt. Ne xt, enter the selection number, fo r port priority settin g. Th ere are four-priority levels – High , Middle , Lo w, and Lowest priority level. High Priorit y : En ter " h " or " H " to enable the ...

  • Milan Technology MIL-S8001TG - page 32

    2 8 Priority ID Map Statu s: To disp lay the current priority level setting fo r each port, ente r “ s ” or “ S ” at the command propmt. If the priority level is not configured, the priority IP mapping will be u ndefined. Restore to De fault: Enter “ r ” or “ R ” at the command prompt to return the QoS control value s back to their ...

  • Milan Technology MIL-S8001TG - page 33

    29 4-4. Broadca st S torm Sup pression Enable or disable the Broadcast storm function. In the main menu command prompt, e nter command ” b ” or “ B ” to enter the Broadcast Storm Suppression configuratio n interface. In the command p rompt sign, enter command “ e ” or “ E ” to enable the broadcast storm f unction. To disable t he br ...

  • Milan Technology MIL-S8001TG - page 34

    3 0 4-5. Restore to Defau lt Enter “ d ” or “ D ” a t the main menu command prompt to return the system to the default value s. 4-6. Rese t Syste m Enter “ r ” or “ R ” a t the main menu command prompt to restart the system. Note: The c urrent configuration w ill remain aft er the system has been restarted. ...

  • Milan Technology MIL-S8001TG - page 35

    31 5. Troubleshoo ting This section is in tended to help you solve some common problems encount ered while using the MIL-S8001TG s witch. Incorrec t connectio ns The switch po rt can auto detect straight o r crossover cable when you link switch with othe r Ethernet device. For the RJ-45 connector shou ld use correct UTP or STP cable, 10/100Mbps por ...

  • Milan Technology MIL-S8001TG - page 36

    3 2  Improper Network Topo logies It is important to make sure that you have a valid network topolo gy. Common topology fau lts include excessive cable length an d too many repeaters or h ubs between end nodes. In addition, you should make sure that your network topology contain s no data path loops. Between any two ends nodes, th ere should be ...

  • Milan Technology MIL-S8001TG - page 37

    33 6. Technical Specif ications This section p rovides the specifications of t he MIL-S8001TG switch produ ct. Standard IEEE 802.3 10 BASE-T Ethernet, IEEE 802.3u 1 00BASE-TX Fast Ethernet IEEE 802.3ab 1000BASE-T Gigabit Co pper IEEE 802.3z Gigab it fiber IEEE802.3x Flow Contro l and Back-pre ssure IEEE802.1p Quality of Service IEEE802.1Q Tag VLAN ...

  • Milan Technology MIL-S8001TG - page 38

    3 4 MINI GBIC: 3. 3V MINI GBIC slot shared with port #1 Back-plane 16Gbps MAC address 4K Mac with A uto Learning Memory 1.5Mbits for packe t buffer Dimensions 250mm x 132m m x 37mm (L x W x H) Power S upply Input: AC 10 0-240V, 50/60Hz Output: 5V/4A (internal) Power Consumption 22 Watt (ma ximum) Operating Temperature 0ºC to 45ºC (3 2ºF to 113º ...

  • Milan Technology MIL-S8001TG - page 39

    35 Rev A ...

Fabricante Milan Technology Categoría Switch

Los documentos del dispositivo Milan Technology MIL-S8001TG que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Milan Technology
- manuales de instrucciones MIL-S8001TG
- hojas de producto Milan Technology
- folletos informativos
- o etiquetas energéticas Milan Technology MIL-S8001TG
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Milan Technology MIL-S8001TG.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Milan Technology MIL-S8001TG, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Milan Technology MIL-S8001TG. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Milan Technology MIL-S8001TG.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Milan Technology MIL-S8001TG, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Milan Technology MIL-S8001TG. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Milan Technology MIL-S8001TG.

El manual de instrucciones completo de Milan Technology debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Milan Technology MIL-S8001TG - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Milan Technology MIL-S8001TG, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Milan Technology MIL-S8001TG que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Milan Technology MIL-S8001TG - que deben facilitarnos los primeros pasos durante el uso de Milan Technology MIL-S8001TG
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Milan Technology MIL-S8001TG
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Milan Technology MIL-S8001TG en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Milan Technology MIL-S8001TG?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Milan Technology MIL-S8001TG, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Milan Technology MIL-S8001TG probablemente compartirá una forma de solucionarlo.