Manual de instrucciones Bunn VPS

17 de páginas 0.61 mb
Descargar

Pasar a la página of 17

Summary
  • Bunn VPS - page 1

    BU N N ® OPERA TING & SER VICE MANU AL B UNN-O-MA TIC CORPORA TION OF CANAD A L TD . 280 INDUSTRIAL PKWY . S. AURORA, ONT ARIO L4G 3T9 PHONE: (905) 841-2866 F AX: (905) 841-2775 10053.7000J 11/01 ©1996 Bunn-O-Matic Corporation www.bunnomatic.com VPR VPS P O U R IN W A T E R O N L Y P O U R IN W A T E R O N L Y ...

  • Bunn VPS - page 2

    Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It is only for indoor use on a sturdy counter or shelf. W ARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and ap ...

  • Bunn VPS - page 3

    Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. #12364.7000 #00833.7001 #00658.7000 #00831.0002 10053 022300 ...

  • Bunn VPS - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. The brewer has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. Electrical Hook-Up (Model "A" Only) CAUTION – Improper electrical installation will dam ...

  • Bunn VPS - page 5

    Page 5 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by ...

  • Bunn VPS - page 6

    Page 6 TROUBLESHOOTING (cont.) PROBLEM Dripping from sprayhead Beverage overflows dispenser Weak beverage PROBABLE CAUSE REMEDY 1. Lime Build-up CAUTION - Tank and tank components should be delimed regularly depending on local water conditions. Excessive mineral build-up on stainless steel surfaces can initiate corro- sive reactions resulting in se ...

  • Bunn VPS - page 7

    Page 7 TROUBLESHOOTING (cont.) PROBLEM Dry coffee grounds remain in the funnel Brewer is making unusal noises Cool beverage serving tempera- ture PROBABLE CAUSE REMEDY 1. Funnel Loading 1. Tank Heater 1. ON/OFF Warmer Switch 2. Warmer Element(s) The BUNN ® paper filter must be centered in the funnel and the bed of grounds leveled by gently shak- i ...

  • Bunn VPS - page 8

    Page 8 P O U R IN W A T E R O N L Y P O U R IN W A T E R O N L Y SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal e ...

  • Bunn VPS - page 9

    Page 9 FIG. 3 CONTROL THERMOSTAT CONTROL THERMOSTAT Location: The control thermostat is located inside the hood on the left end of the mounting bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Locate the black wire on the control thermostat. 3. Check the voltage across the black wire on the control thermostat and the whi ...

  • Bunn VPS - page 10

    Page 10 FIG. 6 LIMIT THERMOSTAT TERMINALS SERVICE (cont.) CONTROL THERMOSTAT (cont.) LIMIT THERMOSTAT - VPR, VPS Location: The limit thermostat is located inside the hood on the right side of the tank lid. P2414 FIG. 5 LIMIT THERMOSTAT P1800 BLK to Tank Heater BLU/BLK to Control Thermostat 10053 073001 2. Remove the thermostat capillary bulb by fir ...

  • Bunn VPS - page 11

    Page 11 ...

  • Bunn VPS - page 12

    Page 12 TANK HEATER Location: The tank heater is located inside the tank and secured to the tank lid. Test Procedures: 1. Disconnect the brewer from the power supply. 2. Check the voltage across the black and white wires on 120 volt models or the black and red wires for 220 volt models with a voltmeter. Plug- in the brewer to the power source. The ...

  • Bunn VPS - page 13

    Page 13 SERVICE (cont.) TANK HEATER (Cont.) BLK to Limit Thermostat (120V Models) Thermal Cut-off to Blu/BLK Lead From Control Thermostat (220V T wo Wire Models) WHI to WHI Lead on Power Cord (120V Models) Thermal Cut-off to Red from Power Connector (220V T wo Wire Models) P1254 FIG. 10 TANK HEATER TERMINALS THERMAL CUT-OFF - VPRA, VPSA BUNN OFF HI ...

  • Bunn VPS - page 14

    Page 14 SERVICE (cont.) WHI to WHI Lead on Power Cord (120V Brewers) RED to Power Connector (220V Brewers) WHI /RED, VIO or BRN/BLK to ON/OFF Switch P1255 FIG. 14 WARMER ELEMENT TERMINALS WARMER ELEMENTS ...

  • Bunn VPS - page 15

    Page 15 L1 BLK TANK HEATER WHI LOWER WARMER 1150W BLK SCHEMATIC WIRING DIAGRAM VPR GREEN N WHI WHI BLK 10050.0000D 1/97 © 1988 BUNN-O-MATIC CORPORATION UPPER WARMER WHI WHI BLK 120 VOLTS A C 2 WIRE SINGLE PHASE 60 HZ WHI/RED WHI/RED VIO VIO 100W 100W LIMIT THERMOSTAT BLU/BLK SW. & THERMOSTAT ON/OFF SWITCH ON/OFF SWITCH IND IND 10053 073001 L1 ...

  • Bunn VPS - page 16

    Page 16 SW. & THERMOSTAT L1 LOWER WARMER 2000W 100W BLK SCHEMATIC WIRING DIAGRAM VPRA GRN/YEL BLU/BLK L2 BLK RED UPPER WARMER 100W BLK IND IND IND BLK 220 VOLTS A C 2 WIRE SINGLE PHASE TANK HEATER RED RED RED RED RED THERMAL CUT-OFF THERMAL CUT-OFF ON/OFF SWITCH ON/OFF SWITCH WHI/RED WHI/RED VIO VIO 10053 073001 LIMIT THERMOSTAT L1 BLK WHI LOWE ...

  • Bunn VPS - page 17

    Page 17 SW. & THERMOSTAT L1 LOWER LEFT WARMER 2000W 100W BLK SCHEMATIC WIRING DIAGRAM VPSA GRN/YEL BLU/BLK L2 BLK RED UPPER WARMER 100W BLK IND IND IND LOWER RIGHT WARMER 100W BLK IND BLK 220 VOLTS A C 2 WIRE SINGLE PHASE TANK HEATER RED RED RED RED RED RED RED THERMAL CUT-OFF THERMAL CUT-OFF ON/OFF SWITCH ON/OFF SWITCH ON/OFF SWITCH WHI/RED WH ...

Fabricante Bunn Categoría Coffeemaker

Los documentos del dispositivo Bunn VPS que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bunn
- manuales de instrucciones VPS
- hojas de producto Bunn
- folletos informativos
- o etiquetas energéticas Bunn VPS
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bunn VPS.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bunn VPS, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bunn VPS. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bunn VPS.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bunn VPS, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bunn VPS. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bunn VPS.

El manual de instrucciones completo de Bunn debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bunn VPS - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bunn VPS, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bunn VPS que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bunn VPS - que deben facilitarnos los primeros pasos durante el uso de Bunn VPS
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bunn VPS
5. FAQ - las preguntas frecuentes