Manual de instrucciones Stovax 7017

28 de páginas 0.54 mb
Descargar

Pasar a la página of 28

Summary
  • Stovax 7017 - page 1

    Sheraton Free Standing Stove M ODELS: 7016/7017/7027 PM216 - Issue 1 (Sept 2007) Instructions for Use, Installation and Servicing For use in Great Britain and Republic of Ireland. IMPORTANT This appliance will become hot whilst in operation, it is therefore recommended that a suitable guard should be used for the protection of young children, the e ...

  • Stovax 7017 - page 2

    COVERING THE FOLLOWING MODELS: 7016/7017/7027 PAGE APPLIANCE COMMISSIONING CHECKLIST 3 OPERATING INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 9 Technical Specifications 9 Site Requirements 10 Pre-Installation 13 Installation 15 Commissioning 17 SERVICING INSTRUCTIONS 18 Maintenance & Servicing 18 Basic spare parts list 21 Care of your stove 23 Serv ...

  • Stovax 7017 - page 3

    3 APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information:- Dealer appliance was purchased from Name: ................................................................................................................................................................. Address: ..................... ...

  • Stovax 7017 - page 4

    4 OPERATING INSTRUCTIONS Before using this appliance, please read these instructions carefully. 1. GENERAL 1.1 This stove is designed for domestic heating and should only be used for this purpose, and in accordance with the manufacturers operating instructions. 1.2 It must be installed by a competent installer, in accordance with all local regulati ...

  • Stovax 7017 - page 5

    5 OPERATING INSTRUCTIONS DOOR HANDLE 1.12 To Open and Close: Use a protective gloved hand to operate. 1.13 Rotate RH Knob anti-clockwise to open. Rotate clockwise to close. 1.14 Warning: Do not force the handle to turn more than 1/4 turn as damage may occur. 1.15 Never open the door with your bare hands. 1.16 Closing the door is the reverse of the ...

  • Stovax 7017 - page 6

    6 OPERATING INSTRUCTIONS 4.9 The ideal control settings to suit the particular installation and personal preferences will be established by experience in using the stove. 4.10 Do not load fuel higher than the log guard. It is not recommended to load large amounts of logs and burn with the Airwash control on low settings for long periods of time. Th ...

  • Stovax 7017 - page 7

    7 OPERATING INSTRUCTIONS 9.2 Fuel Quality (Solid Fuel) Use only recommended solid fuels, which are approved for use with closed appliances. Symptoms of poor performance related to unsuitable fuels include: • Difficulty getting a fire going and keeping it burning well • Smoky fires with little flame • Dirty glass • Dirty firebricks • Short ...

  • Stovax 7017 - page 8

    8 OPERATING INSTRUCTIONS Windy days - Smoking from the appliance. This could be caused by turbulent airflow around chimney terminal, possibly caused by the position of other buildings or obstacles nearby. This problem is, also, sometimes associated with oversize chimneys, which may even have downdraught problems on calm days. If smoking is a common ...

  • Stovax 7017 - page 9

    9 TECHNICAL SPECIFICATION SHERATON STOVE Nominal Heat Output Wood Seasoned wood (less than 20% moisture content) Briquette smokeless fuel suitable for closed appliances. (Ancit - Phurnacite - Taybrite - Homefire ovals) Solid Fuel Wood Wood Solid Fuel Solid Fuel Wood Solid Fuel kW g/s kW mm inch Wg g/s °C °C mm inch kg All Fuels Flue Draught at No ...

  • Stovax 7017 - page 10

    10 SITE REQUIREMENTS Before installation of this product please read these instructions fully. It is very important to also understand the requirements of the UK Building Regulations (England and Wales – Document J / Scotland - Part F, Eire - Document J), along with any local regulations and working practices that may apply. Should any conflict o ...

  • Stovax 7017 - page 11

    11 HEARTH DIMENSIONS The appliance must stand on a constructional hearth with the minimum dimensions as shown in the diagram below. Check that the building has a suitable loadbearing capacity for the hearth and stove. If in doubt consult a structural engineer for advice before proceeding. PR7216S Constructional Hearth 840mm minimum Constructional H ...

  • Stovax 7017 - page 12

    12 SITE REQUIREMENTS WALLS NEXT TO A HEARTH Solid, non-combustible material e.g. masonary or concrete Thickness W C 150mm minimum 150mm minimum C H Location of Stove Dimensions of non-combustible material around Stove and Hearth Distance ‘C’ Thickness ‘W’ Height ‘H’ If the hearth touches the wall and the stove is placed 0-50mm from the ...

  • Stovax 7017 - page 13

    13 PRE-INSTALLATION CHECKS It is important that adequate ventilation exists and the flue or chimney system that is to be used is in good working condition. Products of combustion that enter the room could be a serious health risk. Before installation of this product we recommend that the flue or chimney system and ventilation requirements are inspe ...

  • Stovax 7017 - page 14

    14 PRE-INSTALLATION CHECKS Without liner system round (diameter) mm mm inch mm inch inch m feet Without liner system (square) minimum dimension With liner or factory made system (diameter) installed in accordance with manufacturers instructions Flue/Chimney Size Flue/Chimney minimum height* * When measured from the top of the stove to the top of th ...

  • Stovax 7017 - page 15

    15 1.4 Lift the stove into position on the prepared hearth area, taking care not to damage the hearth finish. Level stove using foot adjusting bolts. 1.5 Connect the stove to the chimney system, using Stovax enamelled flue pipe and seal the connecting joints. Typical top and rear flue connections are shown. Rear flue pipe installation 1.6 Typical r ...

  • Stovax 7017 - page 16

    16 INSTALLATION INSTRUCTIONS 1.9 Connect a straight piece of flue pipe by inserting it into the flue spigot and seal using fire cement and secure with a suitable self tapping screw. PR7220S 600mm min 1000mm max unsupported Elbow with access cover Size Stovax Part No. 6" 4612 Flue Pipe 915mm (3ft) Size Stovax Part No. 6" 4602 To chimney co ...

  • Stovax 7017 - page 17

    17 1.1 Replace the firebricks, baffle, and log retainer. 1.2 Check the door alignment and catch operation, adjust if required. 1.3 Inspect the door seals for damage and check the operation of the air controls. 1.4 Carry out a final smoke draw test, by first warming the flue with a blowlamp, or similar, for about 10 minutes. Then place a smoke pelle ...

  • Stovax 7017 - page 18

    18 MAINTENANCE and SERVICING See chart on page 19 for common spare parts refered to in this section. For a complete list of spare parts and accessories contact your Stovax dealer for the Stovax Fireplace, Stove & Hearth Accessories brochure or call 01392 474011 1. GENERAL CLEANING Before any cleaning is carried out, allow stove to cool thorough ...

  • Stovax 7017 - page 19

    19 This is a list of the maintenance products you may need to use Task Product name Stovax Code Number Glass cleaning Stove glass cleaner 500ml (wipe on) 4111 Stove glass cleaner (spray on) 4103 Preventing build- up of creosote in flue Protector (15 sachets) 7002 Protector (1kg tub) 7025 Sealing flue pipe joints Fire Cement (500g tub) 2020 Fire Cem ...

  • Stovax 7017 - page 20

    20 MAINTENANCE and SERVICING Fixing Screw (x10) Fixing Clip (x4) Glass (x2) Glass Seal (3mm) Door (x2) 8.3 Using a screwdriver remove the glass clip fixing screws. The old glass can then be lifted clear of the door. (Note how the 3mm sealing rope is placed between the glass and the door.) Remember to dispose of the old glass safely. 8.4 Clean and r ...

  • Stovax 7017 - page 21

    21 BASIC SPARE PARTS LIST ...

  • Stovax 7017 - page 22

    22 BASIC SPARE PARTS LIST Part No. Descritpion Casting No. SH1 Blanking Plate 54792/175 SH2 Flue Adapter 54792/180 SH4 Side Plate 54792/120 SH6 Front Plate 54792/060 SH7 Leg 54792/010 SH8 Lip Plate 54792/040 SH9 Base Plate 54792/030 SH10 Door Frame - LH 54792/025 SH11 Door Frame - RH 54792/070 SH13 Door Catch Assembly - RH SH16 Draught Adjuster 547 ...

  • Stovax 7017 - page 23

    23 Product Description Code 3047 Extra long matches 4293 Fire lighters 5039 Gas lighter 4052 Log basket 3048 Wood sling - for easy carrying of logs 3016 Log tongs 4027 Extra long protective gloves 3046 Stove pipe thermometer 5038 Hearthgate - 5 section (for areas 1780x610mm) 5044 Hearthgate - 7 section (for areas 1780x405mm) 4227 Ash caddy - 382x10 ...

  • Stovax 7017 - page 24

    24 ...

  • Stovax 7017 - page 25

    25 ...

  • Stovax 7017 - page 26

    SERVICE RECORDS 26 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:........................................................................................ Dealer's Stamp/HETAS Registration Num ...

  • Stovax 7017 - page 27

    27 ...

  • Stovax 7017 - page 28

    Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.com ...

Fabricante Stovax Categoría Stove

Los documentos del dispositivo Stovax 7017 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Stovax
- manuales de instrucciones 7017
- hojas de producto Stovax
- folletos informativos
- o etiquetas energéticas Stovax 7017
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Stovax 7017.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Stovax 7017, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Stovax 7017. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Stovax 7017.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Stovax 7017, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Stovax 7017. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Stovax 7017.

El manual de instrucciones completo de Stovax debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Stovax 7017 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Stovax 7017, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Stovax 7017 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Stovax 7017 - que deben facilitarnos los primeros pasos durante el uso de Stovax 7017
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Stovax 7017
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Stovax 7017 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Stovax 7017?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Stovax 7017, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Stovax 7017 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen