    GE Monogram ® Installation Instr uctions 36" Downdraft Gas Cooktops Models ZGU365 ...

  • GE Monogram ZGU365 - page 2

    CAUTION 2 Before you begin—Read these instr uctions completely and carefully . IMPORT ANT: Save these instr uctions for local inspector’s use. IMPORT ANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INST ALLER: Be sure to leave these instr uctions with the Consumer . NOTE TO CONSUMER: Keep these instr uctions with your Owners Manual for ...

  • GE Monogram ZGU365 - page 3

    3 Models Available ZGU365 36" gas downdraft cooktops Design Infor mation G a s D owndraf t Co ok top These models are shipped for natural gas operation. They can be converted to liquid propane. (Order JXLP56 conversion kit.) These gas downdraft cooktops are equipped with an vent system which can be retracted when not in use. • JXBA56WW , whi ...

  • GE Monogram ZGU365 - page 4

    4 Design Infor mation G a s D owndraf t Co ok top Advance Planning Clearances • The downdraft system with blower , motor and ductwork will occupy the cabinet below the cooktop. Drawers cannot be installed below this cooktop. • Refer to “Dimensions & Clearances” for information on appropriate placement and necessar y clearances when plan ...

  • GE Monogram ZGU365 - page 5

    5 Cut the Opening Cabinetr y/Ductwork G a s D owndraf t Co ok to p Measure carefully when cutting countertop. Make sure sides of opening are parallel and rear and front cuts are exactly perpendicular to sides. • The Monogram gas downdraft cooktop is designed to fit in a 36" or larger base cabinet. • The countertop cutout for the cooktop mu ...

  • GE Monogram ZGU365 - page 6

    6 Ductwork G a s D owndraf t Co ok top V enting Options • The downdraft vent is shipped with the discharge outlet pointing straight down and can be changed to the left or right side. • The blower outlet is sized for 3-1/2" x 10" and can be transitioned to 6" round. Side to side adjustments: The entire blower mounting plate can be ...

  • GE Monogram ZGU365 - page 7

    7 Ductwork G a s D owndraf t Co ok top Duct Fittings T otal Equivalent Quantity Equivalent Duct Piece Dimensions Length* Used Length 1 ft. 6" round, (per foot straight length) 1 ft. 3 -1 ⁄ 4" x 10" (per foot straight length) 6" 90 ° elbow 15 ft. 6" 45 ° elbow 9 ft. 3 -1 ⁄ 4" x 10" 90 ° elbow 16 ft. 3 -1 ⁄ ...

  • GE Monogram ZGU365 - page 8

    8 Gas and Electrical Supply G a s D owndraf t Co ok top Gas supply: These cooktops are designed to operate on natural gas at 4" of water column pressure or on LP gas at 10" of water column pressure. – These cooktops are shipped from the factor y set for natural gas. If you decide to use this cooktop with LP gas, conversion adjustments m ...

  • GE Monogram ZGU365 - page 9

    9 Installation G a s D owndraf t Co ok top Remove Packaging • Remove the shipping materials and the carton, set carton aside. The carton can be used as a pad when changing or adjusting vent direction. • Remove the plastic ties on both ends at the top of the vent. Plastic T ies 1 Install Downdraft V ent Step Place the downdraft vent into the cou ...

  • GE Monogram ZGU365 - page 10

    10 Installation G a s D owndraf t Co ok top • Install the supplied pressure regulator and nipple in the gas line as close to the cooktop inlet as possible. Allowances for ventilation ducting may be necessar y . –Make sure the regulator is installed in the right direction. • Install a manual shut-off valve in the gas line in an easily accessib ...

  • GE Monogram ZGU365 - page 11

    11 Installation G a s D owndraf t Co ok to p Note: If the cooktop is installed into a 36" base cabinet, the pressure regulator MUST BE installed to the bottom of the cooktop before the cooktop is placed into the cabinet. • Remove packaging from the cooktop. • T o insure a good fit, position the cooktop over the cutout opening and carefully ...

  • GE Monogram ZGU365 - page 12

    12 Installation G a s D owndraf t Coo k top 5 Electrical Connections Step • Connect the 3-pin plastic plug from the blower/motor assembly to the 3-pin plastic socket on the underside of the vent, next to the conduit. • Slide the metal cover over the connection and secure with screws. 6 Connect Power Step • Plug power cords into properly groun ...

  • GE Monogram ZGU365 - page 13

    13 Installation G a s D owndraf t Co ok top T o raise the vent, tur n the VENT knob to RAISE/LOWER. • Hold the knob until the vent begins to raise. – The vent will automatically stop when it is fully extended. • T ip filter into the opening and pull straight down so that the filter rests on slides. • Slide the filter to the right side. • ...

  • GE Monogram ZGU365 - page 14

    14 JXRB57 Kit For Indoor Remote Blower Locations Tools and Materials required: • Pencil • Measuring tape • Drill with appropriate bits • Nut driver • Junction box • Wire nuts • Safety glasses • 3-1/4" x 10" to 6" round transition. • 3-1/4 x 10" duct, (or 6" round) sufficient length to reach the outdoor wal ...

  • GE Monogram ZGU365 - page 15

    15 JXRB57 Kit For Indoor Remote Blower Locations • Remove the 4 nuts holding the blower to the mounting plate. One nut is hidden inside the outlet. Remove blower . • Remove the blower mounting plate. • Remove 2 screws along the bottom of the blower box which are visible once blower plate is removed. • Carefully , turn the unit over to acces ...

  • GE Monogram ZGU365 - page 16

    16 4 Connect Electrical Step 3 Connect Ductwork Step JXRB57 Kit For Indoor Remote Blower Locations Duct Adapter Outlet Cover Downdraft • The downdraft plenum can discharge from either the right or left side. Select the side that provides the best alignment to ductwork extending to the blower assembly below . – For a left side discharge, install ...

  • GE Monogram ZGU365 - page 17

    17 JXBC57 Kit For Outdoor Remote Blower Locations Materials Required (not supplied) • Approved liquid tight service connections for use between the wire compartment on the base and inside the structure. • 7 wire nuts or other approved connectors. • Six 5/16" dia. fasteners compatible with the type of material the base is being fastened t ...

  • GE Monogram ZGU365 - page 18

    18 JXBC57 Kit For Outdoor Remote Blower Locations 2 Mark Mounting Location Step • The base is designed to be mounted to studs on 16" centers. Use the dimensions shown to deter mine the location of the ducting and wiring through the wall. – Or Place the base against the exterior wall and mark the 6 mounting locations, the 6" duct locat ...

  • GE Monogram ZGU365 - page 19

    19 JXBC57 Kit For Outdoor Remote Blower Locations 3 (continued) Step • Remove the 4 nuts holding the blower to the mounting plate. One nut is hidden inside the outlet. Remove blower . • Remove the blower mounting plate. • Remove 2 screws along the bottom of the blower box which are visible once blower plate is removed. • Carefully , turn th ...

  • GE Monogram ZGU365 - page 20

    20 JXBC57 Kit For Outdoor Remote Blower Locations 5 Connect Electrical Step • Use electrical cable and connectors that conform to local codes (14 gauge min. is recommended). Use a length to reach between the vent and the blower/motor location. • Attach the wire box removed from the blower conduit to the end of new wiaring. • Use wire nuts to ...

  • GE Monogram ZGU365 - page 21

    21 Notes ...

  • GE Monogram ZGU365 - page 22

    22 Notes ...

  • GE Monogram ZGU365 - page 23

    23 Notes ...

  • GE Monogram ZGU365 - page 24

    NOTE: While performing installations described in this book, safety glasses or goggles should be worn. T o obtain specific information concerning any Monogram product or service, call GE Answer Center ® consumer information service at 800.626.2000—any time, day or night. For Monogram local ser vice in your ar ea, call 1-800-444-1845. NOTE: Produ ...

Fabricante GE Monogram Categoría Cooktop

Los documentos del dispositivo GE Monogram ZGU365 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos GE Monogram
- manuales de instrucciones ZGU365
- hojas de producto GE Monogram
- folletos informativos
- o etiquetas energéticas GE Monogram ZGU365
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones GE Monogram ZGU365.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje GE Monogram ZGU365, instrucciones de servicio, instrucciones cortas o instrucciones de usuario GE Monogram ZGU365. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto GE Monogram ZGU365.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo GE Monogram ZGU365, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar GE Monogram ZGU365. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de GE Monogram ZGU365.

El manual de instrucciones completo de GE Monogram debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual GE Monogram ZGU365 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice GE Monogram ZGU365, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de GE Monogram ZGU365 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo GE Monogram ZGU365 - que deben facilitarnos los primeros pasos durante el uso de GE Monogram ZGU365
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con GE Monogram ZGU365
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de GE Monogram ZGU365 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de GE Monogram ZGU365?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con GE Monogram ZGU365, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con GE Monogram ZGU365 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)