Manual de instrucciones Aico Ei Ei161RC

16 de páginas 1.79 mb
Descargar

Pasar a la página of 16

Summary
  • Aico Ei Ei161RC - page 1

    2 1.1 Installation Guide B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 1 ...

  • Aico Ei Ei161RC - page 2

    2. ALARM REMOVAL SLIDE ALARM OFF BASE WITH TH E SCREW DRIVER ST ILL IN SERTED , PUSH TH E LOWER HALF OF TH E ALARM AWAY FR OM THE S CREW DRIVER, IN T HE DIRECTION OF THE ARROW ON THE COVER HOLD THE L OWER HALF OF THE AL ARM AND REM OVE FROM THE BASE PLA TE BY MOVING IT VERTICALLY DO WNWARDS, T O WARD S THE FL OO R. REMOVE AL ARM LOCATE REMOVA L SL ...

  • Aico Ei Ei161RC - page 3

    2. HO W MANY ALARMS T O INST ALL - CA TEGORIES & GRADES - The advice here f ollows the guidance in British Standard BS 5839-P ar t 6: 2004 in general (f or fur ther inf or mation see the BS standard itself). The main reason f or fitting Smoke & Heat Alarms in dwellings is to ensure that when there is a fire, sufficient early warning is giv ...

  • Aico Ei Ei161RC - page 4

    for e xisting dwellings MINIMUM PR O TECTION LD3 Minimum Pr otection LD3: Smoke Alarms in all hallwa ys, stairwa ys and circulation areas that form par t of the escape routes from the dwelling. Multi Storey Dwelling LD3 Living Room Bedroom Bathroom Kitchen Bedroom Shower Garage Smoke Alarms located: on each storey e very 7.5 m of hallwa ys and esca ...

  • Aico Ei Ei161RC - page 5

    Additional Pr otection LD2: As LD3, but in addition Smoke or Heat Alarms in all rooms or areas that present a high fire risk to occupants. Heat Alarms located in: (Heat Alarms must be within 5.3m of potential fire sources) each Kitchen Smoke or Heat Alarms located in: each Living room (i.e. most frequently used da ytime room) Smoke Alarms located: ...

  • Aico Ei Ei161RC - page 6

    for d wellings where occupants may be at high risk (e.g. elderly) OPTIMUM PR O TECTION LD1 Optimum Pr otection LD1: As LD2, b ut in addition Smoke or Heat Alarms should be located in all rooms and other areas of the dwelling. (apar t from toilets or bathroom) Multi Storey Dwelling LD1 Heat Alarms located in: (Heat Alarms must be within 5.3m of pote ...

  • Aico Ei Ei161RC - page 7

    2.2 Selecting Alarm T ype 1 Optical Smoke Alarms are recommended due to their excellent response to smouldering fires. If there is likely to be prob lems with steam, contamination or dust build-up , or if there is significant r isk of a f ast burning clean fire an Ionisation Smoke Alarm should be fitted. 2 Some Fire Authorities recommend that both ...

  • Aico Ei Ei161RC - page 8

    Impro ved Audibility The eff ectiveness of Category LD2 and LD3 systems can be significantly enhanced if an additional Smoke Alarm (interconnected) is installed in the master bedroom. This will help ensure that a responsible person will quic kly be aler ted to a fire and can arrange f or an orderly ev acuation of children and other vulnerable occup ...

  • Aico Ei Ei161RC - page 9

    3.1 Locations T o A void DON’T place Smoke Alarms in any of the f ollowing areas: • Bathrooms, kitchens , shower rooms , garages or other rooms where the smoke alarm may be triggered b y steam, condensation, normal smoke or fumes. K eep at least 6 metres awa y from sources of normal smoke/fumes. DON’T place Heat Alarms in any of the f ollowin ...

  • Aico Ei Ei161RC - page 10

    appropriate. (Excessive dust and debris from b uilding work can contaminate the smoke c hamber or heat sensor and cause prob lems, it will also in validate the guarantee) . If it must be installed, first co ver it completely , particularly around the edges, with a dust cover (eg. with the elasticated cover supplied or a plastic ba g), until all cle ...

  • Aico Ei Ei161RC - page 11

    See page 14 f or inf ormation on interconnection. Note: Wiring must be installed in compliance with local regulations. W arning: Mixing the Live and Neutral connections when interconnecting alar ms will damage all the alarms - ensure that the same colours are used throughout the premises f or Liv e, Neutral and Interconnect wires . W e strongly rec ...

  • Aico Ei Ei161RC - page 12

    If the mains wires are being brought along the surf ace: (a) position the mounting plate so the cable trunking is as shown in Figure 4 . (b) the mounting plate has a remov able section, take it out to interf ace directly with 25 mm conduit as shown in Figure 5 .I f interf acing to 16 mm conduit carefully cut around the marked section, leaving the t ...

  • Aico Ei Ei161RC - page 13

    4.2 Interconnecting Alarms Note: A maximum of twelv e Ei141/144/146/161RC /164RC/166RC Smoke or Heat Alarms may be interconnected along with an Ei128R pattress with rela y (see “ A CCESSORIES ” section on page 15). If you wish to connect more than tw elv e alar ms contact y our local distributor (see page 16 f or details). Systems using more th ...

  • Aico Ei Ei161RC - page 14

    These Smoke/Heat Alarms should be interconnected only within the confines of a single f amily living unit. If the y are connected between diff erent units there may be e xcessive nuisance alar ms. Ever ybody ma y not be aware that the y are being tested or that it is a nuisance alarm caused by cooking etc. Ensure the alar ms operate correctly - see ...

  • Aico Ei Ei161RC - page 15

    Aico Ltd . Mile End Business P ark, Maesbury Rd, Oswestry , Shropshire SY10 8NN, U .K. T el: 0870 758 4000 www .aico.co.uk Ei Electronics. Shannon, Co Clare, Ireland. T el: 061 471277 www .eielectr onics.com 1 2 3 4 4 8 9 9 10 10 11 14 15 1. QUICK GUIDE 1.1 INST ALLA TION GUIDE 1.2 ALARM REMO V AL 2. HO W MANY ALARMS TO INST ALL 2.1 CA TEGORIES OF ...

  • Aico Ei Ei161RC - page 16

    INSTALLER INSTRUCTIONS IDEALLY INSTALL IN THE CENTRE OF CEILING AT LEAST 300mm FROM LIGHT FITTINGS LOCATE IONISATION ALARMS AWAY FROM KITCHENS TO PREVENT NUISANCE ALARMS ENSURE LIVE MAINS IS CORRECTLY CONNECTED TO L TERMINALS ON ALL INTERCONNECTED ALARMS - OTHERWISE UNITS WILL BE DAMAGED DO NOT FIT ACTUAL ALARM UNTIL ALL BUILDING WORK IS COMPLETED ...

Fabricante Aico Categoría Smoke Alarm

Los documentos del dispositivo Aico Ei Ei161RC que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Aico
- manuales de instrucciones Ei Ei161RC
- hojas de producto Aico
- folletos informativos
- o etiquetas energéticas Aico Ei Ei161RC
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Aico Ei Ei161RC.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Aico Ei Ei161RC, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Aico Ei Ei161RC. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Aico Ei Ei161RC.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Aico Ei Ei161RC, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Aico Ei Ei161RC. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Aico Ei Ei161RC.

El manual de instrucciones completo de Aico debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Aico Ei Ei161RC - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Aico Ei Ei161RC, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Aico Ei Ei161RC que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Aico Ei Ei161RC - que deben facilitarnos los primeros pasos durante el uso de Aico Ei Ei161RC
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Aico Ei Ei161RC
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Aico Ei Ei161RC en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Aico Ei Ei161RC?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Aico Ei Ei161RC, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Aico Ei Ei161RC probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)