    H8S/2338 Series QFP-144 User System Interface Cable (HS2338ECH61H) for E6000 Emulator User’s Manual HS2338ECH61HE(D) ...

  • Renesas QFP-144 - page 2

    Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document. Renesas bears no responsibility fo r problem s that may arise with third party’s rights, including int ellectual property ...

  • Renesas QFP-144 - page 3

    i Preface Thank you for purchasing this user system interface cable (HS2338ECH61H) for the Renesas’s original mi crocomputer H8S/2338 series. The HS2338ECH61H is a user system interface cable that connects an H8S/2338 series E6000 emulator (HS2338EPI61H; hereinafter referred to as the emul ator) to the IC socket for a QFP-144 package (package cod ...

  • Renesas QFP-144 - page 4

    ii Contents Section 1 Configuration ................................................................................... 1 Section 2 Connection Procedures .................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station ......................................... 4 2.2 Connecting ...

  • Renesas QFP-144 - page 5

    Section 1 Configuration 1 UTION CA Use an NQPACK144SD socket (manufactured by Tokyo Eletech Coporation) for the FP-144 package IC socket on the user system. Figure 1 shows the configuration of the HS2338E CH61H user system interface cable for the FP-144 package. ...

  • Renesas QFP-144 - page 6

    To emulator station Cable body Screws (M2 x 6 mm) Socket cover User system IC socket Cable head Screws (M2 x 10 mm) (for fastening cable head) Figure 1 HS2338ECH61H User System Interface Cable 2 ...

  • Renesas QFP-144 - page 7

    3 Table 1 lists t he HS2338ECH61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2338ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-144 package 4 Socket cover 1 For installing an FP-144 packaged MCU 5 Screws (M2 x 10 mm) 4 For fas ...

  • Renesas QFP-144 - page 8

    Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so w ill damage ...

  • Renesas QFP-144 - page 9

    Emulator station E6000 Cable body User system interface cable Figure 2 Connecting User System Interf ace Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before conne ...

  • Renesas QFP-144 - page 10

    2.2.1 Installing IC Socket 1. Confirming t he location of IC socket 6 UTION CA After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket, and fasten it to the user system. Use the guide pins provided to determ ine where to install t he IC socket, as shown in ...

  • Renesas QFP-144 - page 11

    2.2.2 Inserting Cable Head 7 UTION CA Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-144 system interface cable head into the IC socket on the user system, as shown in fi gure 4. 2.2.3 Fastening Cable Head CA UTION 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.054 N• ...

  • Renesas QFP-144 - page 12

    Fasten the user system interface cable head to the IC socket for an FP-144 package on the user system with the four screws (M2 x 10 m m) provided. Each screw should be tightened a little at a time, alternating between screws on opposi ng corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC so ...

  • Renesas QFP-144 - page 13

    2.2.4 Connecting Cable Body to Cabl e Head Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body 9 ...

  • Renesas QFP-144 - page 14

    2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for an FP-144 package (NQPACK144SD: m anufactured by Tokyo Eletech Corporation). Not e that the dimensions in figure 6 are somewhat different from those of t he actual chip's m ou ...

  • Renesas QFP-144 - page 15

    2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 7. Unit: mm Tolerance: –0.5 mm Figure 7 Dimensions for User System Interface Cable Head 11 ...

  • Renesas QFP-144 - page 16

    2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 8. Cable head User system Unit: mm Tolerance: –0.5 mm IC socket (NQPACK144SD manufactured by Tokyo Eletech Corporation) Figure 8 Resulting Dimensions after ...

  • Renesas QFP-144 - page 17

    Section 3 Installing the MCU to the User System 13 UTION CA 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly ...

  • Renesas QFP-144 - page 18

    MCU Pin 1 IC socket (NQPACK144SD manufactured by Tokyo Eleteck Corporation) User system Screws (M2 x 6 mm) Socket cover Figure 9 Installing MCU to User System 14 ...

  • Renesas QFP-144 - page 19

    Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2338 series, turn on the emulator according to the procedures described in the E6000 Series Em ulator User's Ma nual (HS2000EPI61HE). 2. Verify the user system interface cable connec tions by accessing the exte rnal m emory and ports to check the bus states of the pins ...

  • Renesas QFP-144 - page 20

    16 4. In the H8S/2338 series MCU, the interrupt signal pins can be selected by the register setting. To trace the interrupt signals in the E6000 emulator, se lect the interrupt signa l pins by setting switch P5 on the user system interface cable as shown in table 2. Table 2 Switch P5 Setting IRPA S Bit Value Interrupt Si gnal Pin Pin No. P5 Setting ...

  • Renesas QFP-144 - page 21

    Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensi ons of the recommended m ount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifi ...

Fabricante Renesas Categoría Computer Hardware

Los documentos del dispositivo Renesas QFP-144 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Renesas
- manuales de instrucciones QFP-144
- hojas de producto Renesas
- folletos informativos
- o etiquetas energéticas Renesas QFP-144
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Renesas QFP-144.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Renesas QFP-144, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Renesas QFP-144. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Renesas QFP-144.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Renesas QFP-144, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Renesas QFP-144. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Renesas QFP-144.

El manual de instrucciones completo de Renesas debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Renesas QFP-144 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Renesas QFP-144, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Renesas QFP-144 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Renesas QFP-144 - que deben facilitarnos los primeros pasos durante el uso de Renesas QFP-144
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Renesas QFP-144
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Renesas QFP-144 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Renesas QFP-144?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Renesas QFP-144, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Renesas QFP-144 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)