Manual de instrucciones Lincoln Electric INVERTEC IM465-B

33 de páginas 0.43 mb
Descargar

Pasar a la página of 33

Summary
  • Lincoln Electric INVERTEC IM465-B - page 1

    INVER TEC DC TIG S T AR TER OPERA TOR’S MANUAL This manual for use with DC TIG Starter Codes 9926, 9990 & 10368 IM465-B October, 1999 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on ...

  • Lincoln Electric INVERTEC IM465-B - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric INVERTEC IM465-B - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric INVERTEC IM465-B - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric INVERTEC IM465-B - page 5

    iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits ...

  • Lincoln Electric INVERTEC IM465-B - page 6

    Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay par ...

  • Lincoln Electric INVERTEC IM465-B - page 7

    vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Product Description ............................................................ ...

  • Lincoln Electric INVERTEC IM465-B - page 8

    NO TES ...

  • Lincoln Electric INVERTEC IM465-B - page 9

    INPUT Standard Voltage/Frequency Input Current 42 VAC ± 15% / 50/60 Hz. 2.0 Amps - Rated Output A-1 INST ALLA TION INVERTEC DC TIG STARTER A-1 TECHNICAL SPECIFICA TIONS – DC TIG ST ARTER CURRENT LIMIT Height Width Depth Weight 6.44 in 10.72 in 21.01 in 23 Ibs 164 mm 272 mm 523 mm 10.4 kg PHYSICAL DIMENSIONS Duty Cycle Amps 60% Duty Cycle 300 100 ...

  • Lincoln Electric INVERTEC IM465-B - page 10

    A-2 INST ALLA TION INVERTEC DC TIG STARTER A-2 PRODUCT DESCRIPTION The purpose of the DC TIG Starter is to provide a high frequency, high voltage pulse for arc starting in DC TIG welding applications. It is intended to be used with the Invertec™ power sources which have a 5.5 amp, 42 VAC auxiliary supply. The DC TIG Starter’s output rating matc ...

  • Lincoln Electric INVERTEC IM465-B - page 11

    A-3 INST ALLA TION INVERTEC DC TIG STARTER A-3 b. Keep the work and torch leads as short as possible and as close together as possible. Lengths should not exceed 25 ft. (7.6m). Tape the leads together when practical. c. Be sure the torch and work cable rubber coverings are free of cuts and cracks that allow high frequen- cy leakage. d. Keep the tor ...

  • Lincoln Electric INVERTEC IM465-B - page 12

    A-4 INST ALLA TION INVERTEC DC TIG STARTER A-4 Figure 2 below shows connection of water-cooled torches with the required 7/8-RH to 5/8-RH adapter for the gas fitting. The water/coolant inlet connection for the torch should be connected directly to the 7/8-LH water/coolant connection. FIGURE 2 Connection Diagram for Water-Cooled Torches. NOTE: All r ...

  • Lincoln Electric INVERTEC IM465-B - page 13

    B-1 OPERA TION INVERTEC DC TIG STARTER B-1 OPERA TING INSTRUCTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. • Insulate yourself from work and ground. • Always wear dry insulating gloves. ------------------------------------------------------------------------ FUMES AND GASES can b ...

  • Lincoln Electric INVERTEC IM465-B - page 14

    B-2 OPERA TION B-2 INVERTEC DC TIG STARTER Power Source and Starter Kit Operation Duty Cycle The DC TIG Starter kit is rated to match the V300 Invertec’s duty cycle of 300 amps, 60% duty cycle, and 250 amps, 100% duty cycle. Invertec Control Function/Operation Power Switch: Placing the Invertec’s power switch in the “ON” position will energ ...

  • Lincoln Electric INVERTEC IM465-B - page 15

    Trigger Function Switch: This switch selects a 2-step or 4-step trigger function when used with an arc start switch. This switch should be placed in the 2-step position when the DC TIG Starter is used with an amptrol. For best utility, the output terminals switch on the Invertec should be placed in the “REMOTE” posi- tion. Operation with an Arc ...

  • Lincoln Electric INVERTEC IM465-B - page 16

    B-4 OPERA TION B-4 INVERTEC DC TIG STARTER FIGURE 3 2-Step Trigger Control Using Arc Start Switch 4-STEP: In this mode, closing the trigger (or arc start switch) will start the welding process with a 0.5 second gas preflow. The Invertec’s welding terminals will ener- gize and the solid state starting circuit will operate until the trigger is open ...

  • Lincoln Electric INVERTEC IM465-B - page 17

    C-1 A CCESSORIES C-1 There are no factory installed options. The DC TIG Starter comes complete with cables, torch adapters, and hardware for installation. Field Installed Options/Accessories: Cable Plugs: Cable Plug Kit for 1/0-2/0- cable (K852- 70): Attaches to welding cable to provide quick dis- connect from machine. NOTE: A 17” 1/0 cable with ...

  • Lincoln Electric INVERTEC IM465-B - page 18

    D-1 MAINTENANCE D-1 INVERTEC DC TIG STARTER Routine Maintenance 1 . Every 6 months or so the machine should be cleaned with a low pressure airstream. Keeping the machine clean will result in cooler operation and higher reliability. 2. Examine the sheet metal case for dents or break- age. Repair the case as required. Keep the case in good condition ...

  • Lincoln Electric INVERTEC IM465-B - page 19

    If for any reason you do not understand the test procedures or are unable to perform the necessary tests/repairs safely, contact your local authorized field service facility before you proceed. This Troubleshooting Guide is designed to be used by the machine Owner/Operator. Unauthorized repairs performed on this equipment may result in danger to th ...

  • Lincoln Electric INVERTEC IM465-B - page 20

    E-2 TR OUBLESHOO TING E-2 INVERTEC DC TIG STARTER Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CA UT ...

  • Lincoln Electric INVERTEC IM465-B - page 21

    E-3 TR OUBLESHOO TING E-3 INVERTEC DC TIG STARTER Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CA UT ...

  • Lincoln Electric INVERTEC IM465-B - page 22

    E-4 TR OUBLESHOO TING E-4 INVERTEC DC TIG STARTER Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CA UT ...

  • Lincoln Electric INVERTEC IM465-B - page 23

    E-5 TR OUBLESHOO TING E-5 INVERTEC DC TIG STARTER Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CA UT ...

  • Lincoln Electric INVERTEC IM465-B - page 24

    E-6 TR OUBLESHOO TING E-6 INVERTEC DC TIG STARTER Environmental Protection High voltage connections are covered with an RTV sealant to prevent malfunction in severe environ- ments. Sealant must be applied to connections which have been opened or otherwise lost their protection. A noncorrosive electronic grade sealant such as Dow Corning 3140, 3145, ...

  • Lincoln Electric INVERTEC IM465-B - page 25

    F-1 DIA GRAMS F-1 INVERTEC DC TIG STARTER #'  %   # $  # (#%& (? ...

  • Lincoln Electric INVERTEC IM465-B - page 26

    F-2 DIA GRAMS F-2 INVERTEC DC TIG STARTER  , 4  ( %      !"#$%&"'(')*+),-.!--/.%"*'!-0&"" ...

  • Lincoln Electric INVERTEC IM465-B - page 27

    F-3 DIA GRAMS F-3 INVERTEC DC TIG STARTER    '   '   . ...

  • Lincoln Electric INVERTEC IM465-B - page 28

    F-4 DIA GRAMS F-4 INVERTEC DC TIG STARTER ...

  • Lincoln Electric INVERTEC IM465-B - page 29

    NO TES INVERTEC DC TIG STARTER ...

  • Lincoln Electric INVERTEC IM465-B - page 30

    Now A vailab le...12th Edition The Procedure Handbook of Ar c Welding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “Bible” of the arc welding industry. This printing will go fast so don’t delay. Place your order now using the coupon below. The hardbound book contain ...

  • Lincoln Electric INVERTEC IM465-B - page 31

    W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA EL ...

  • Lincoln Electric INVERTEC IM465-B - page 32

    W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes f ...

  • Lincoln Electric INVERTEC IM465-B - page 33

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabricante Lincoln Electric Categoría Remote Starter

Los documentos del dispositivo Lincoln Electric INVERTEC IM465-B que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Lincoln Electric
- manuales de instrucciones INVERTEC IM465-B
- hojas de producto Lincoln Electric
- folletos informativos
- o etiquetas energéticas Lincoln Electric INVERTEC IM465-B
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Lincoln Electric INVERTEC IM465-B.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Lincoln Electric INVERTEC IM465-B, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Lincoln Electric INVERTEC IM465-B. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Lincoln Electric INVERTEC IM465-B.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Lincoln Electric INVERTEC IM465-B, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Lincoln Electric INVERTEC IM465-B. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Lincoln Electric INVERTEC IM465-B.

El manual de instrucciones completo de Lincoln Electric debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Lincoln Electric INVERTEC IM465-B - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Lincoln Electric INVERTEC IM465-B, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Lincoln Electric INVERTEC IM465-B que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Lincoln Electric INVERTEC IM465-B - que deben facilitarnos los primeros pasos durante el uso de Lincoln Electric INVERTEC IM465-B
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Lincoln Electric INVERTEC IM465-B
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Lincoln Electric INVERTEC IM465-B en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Lincoln Electric INVERTEC IM465-B?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Lincoln Electric INVERTEC IM465-B, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Lincoln Electric INVERTEC IM465-B probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)