  • Panamax MAX 5410 - page 1

    MAX ® 5410 Pro Series Owner’ s Manual AC VOLTS 0 150 METER LIGHT TRIGGER SWITCHED OUTLETS GROUND OK LINE FAULT UNSAFE VOLT AGE 1690 Corporate Circle, Petaluma, CA 94954 • www .panamax.com ...

  • Panamax MAX 5410 - page 2

    AC VOLTS 0 150 METER LIGHT TRIGGER SWITCHED OUTLETS GROUND OK LINE FAULT UNSAFE VOLT AGE Congratulations on your selection of the MAX ® 5410 as the AC power source for your audio/video system! Over 25 years of power protection expe- rience and more than 10 years of Audio/Video noise filtration engineer- ing experience were utilized in the developm ...

  • Panamax MAX 5410 - page 3

    1 Before Y ou Begin.........................................................1 Introduction.................................................................2 Connection Diagram....................................................3 Feature Overview.........................................................4 Feature Details Front Panel Pushbutton........ ...

  • Panamax MAX 5410 - page 4

    2 INTRODUCTION • • • • • • A backlit analog voltmeter indicates the AC line voltage coming into your system. A combination ON/OFF/Dimmer switch controls the meter lighting. An always-on, convenience outlet on the front panel for temporary AC connections. Sequential start-up and shut-down of your system using an A/V receiver (or other co ...

  • Panamax MAX 5410 - page 5

    3 AUDIO VIDEO RECEIVER AMPLIFIER VCR SA TELLITE RECEIVER PVR (TiVo) TV CD PLA YER PROPERL Y GROUNDED AC OUTLET 12V TRIGGER IN OUT RS-232 USB LED LIGHT HIGH CURRENT OUTLETS SWITCHED OUTLETS AL WAYS ON OUTLETS SATELLITE CA TV/ANT CIRCUIT BREAKER GROUND LUG AC INLET LINE EQUIP 1 EQUIP 2 T R IG G E R E N A B L E TR IG G E R D E LA Y H IG H C U R R E N ...

  • Panamax MAX 5410 - page 6

    Engineered in the USA Assembled in China 15A BREAKER GROUND IEC320 INLET HIGH CURRENT OUTLETS SWITCHED OUTLETS AL WA YS ON OUTLETS RS232 CONTROL USB LED LIGHT 12V TRIGGER IN OUT TRIGGER ENABLE TRIGGER DELAY HC OUTLETS DELAY SWITCHED OUTLETS DELAY LINE EQUIP . 1 EQUIP . 2 SATELLITE CATV/ANT 4 FEA TURE OVERVIEW Front Panel Pushbutton: 1 of 2 T rigger ...

  • Panamax MAX 5410 - page 7

    5 FEA TURE DET AILS USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 Front Panel Pushbutton This button controls the “High-Current” and “Switched” outlets. Sequential Startup/Shutdown Complex audio/video systems may be susceptible to voltage transients generated inter- nally at start-up/shutdown if all of the equipm ...

  • Panamax MAX 5410 - page 8

    FEA TURE DET AILS 6 Ground OK: Green LED. When this light is ON, it indicates that the wall outlet is properly wired. When the light is OFF , it indicates that the wall outlet has a reversed line and neutral wire, or that there is no ground present. Line Fault: Red LED. When this light is ON, it is indicating that the wall outlet has a reversed lin ...

  • Panamax MAX 5410 - page 9

    7 FEA TURE DET AILS Filtered Outlet Banks Eight Outlets (4 banks / 2 outlets per bank) are fed through cascaded noise filtration circuits. These circuits are designed to eliminate AC contamination that is detrimental to the performance of audio or video components like stereo receivers, VCRs or televisions. The dedicated filters are carefully engin ...

  • Panamax MAX 5410 - page 10

    8 FEA TURE DET AILS Circuit Breaker A circuit breaker is located on the back panel of the MAX ® 5410. The circuit breaker will trip only if the total current draw exceeds the maximum current rating (15A). This means that collectively , all outlets must draw more than 15 Amps before the circuit breaker will trip. 1690 Corporate Circle, Petaluma, CA ...

  • Panamax MAX 5410 - page 11

    Engineered in the USA Assembled in China UTLETS RS232 CONTROL USB LED LIGHT 12V TRIGGER IN OUT TRIGGER ENABLE TRIGGER DELAY HC OUTLETS DELAY SWITCHED OUTLETS DELAY LINE EQUIP. 1 EQUIP . 2 SATELLITE CATV/ANT 9 FEA TURE DET AILS SignalPerfect ™ Coaxial Line Protection All coaxial cable sheaths from outdoors must be grounded to the building groundin ...

  • Panamax MAX 5410 - page 12

    10 FEA TURE DET AILS Protect or Disconnect™ AC Surge Protection When the MAX ® 5410 is subjected to a high voltage surge, its voltage output is limited to a safe level and the high levels of surge current are diverted away from the connected equipment. • When subjected to a 6,000V (open circuit voltage) / 500A (short circuit current) surge, th ...

  • Panamax MAX 5410 - page 13

    11 TECHNICAL SPECIFICA TIONS Clamping Level..............................................................................................260V Capacitance......................................................................................30pf (approx.) Suppression Modes...........................................................Metallic & Longi ...

  • Panamax MAX 5410 - page 14

    My MAX ® 5410 power cable does not reach the wall outlet. Can I use an extension cord to make it reach? Y es, but you must use only Panamax extension cords to keep your warranty valid. Ask for part # GEC1410. (10 feet long) or #P12X10NEMA5-15. Can the MAX ® 5410 be included in an equipment rack? The included rack-mount kit allows you to mount the ...

  • Panamax MAX 5410 - page 15

    USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901 13 MAX PRO-SERIES RS-232 COMMAND SPECIFICA TIONS Changes the front panel button status to ON. Initiates a power -on sequence if the previous state is OFF . Changes the front panel button status to OFF . Initiates a power -off sequence if the previous state is ON. (Default) In ...

Fabricante Panamax Categoría Power Supply

Los documentos del dispositivo Panamax MAX 5410 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Panamax
- manuales de instrucciones MAX 5410
- hojas de producto Panamax
- folletos informativos
- o etiquetas energéticas Panamax MAX 5410
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Panamax MAX 5410.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Panamax MAX 5410, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Panamax MAX 5410. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Panamax MAX 5410.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Panamax MAX 5410, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Panamax MAX 5410. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Panamax MAX 5410.

El manual de instrucciones completo de Panamax debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Panamax MAX 5410 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Panamax MAX 5410, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Panamax MAX 5410 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Panamax MAX 5410 - que deben facilitarnos los primeros pasos durante el uso de Panamax MAX 5410
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Panamax MAX 5410
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Panamax MAX 5410 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Panamax MAX 5410?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Panamax MAX 5410, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Panamax MAX 5410 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)