  • Friedrich MS36Y3F - page 1

    CONTENTS SPECIFICATIONS .................. 1 OUTLINE AND DIMENSIONS ......... 2 REFRIGERANT SYSTEM DIAGRAM .... 4 CIRCUIT DIAGRAM ................. 5 INDOOR PCB CIRCUIT DIAGRAM ..... 7 OUTDOOR PCB CIRCUIT DIAGRAM ... 8 ERROR CONTENTS ............... 11 DISASSEMBLY ILLUSTRATION ...... 13 PARTS LIST ...................... 21 ACCESSORIES ............. ...

  • Friedrich MS36Y3F - page 2

    Pipe length 49 ft. (15 m) 4 lb 14 oz (2,200 g) 66 ft. (20 m) 5 lb 5 oz (2,400 g) 98 ft. (30 m) 6 lb 3 oz (2,800 g) 131 ft. (40 m) 7 lb 1 oz (3,200 g) 164 ft. (50 m) 7 lb 15 oz (3,600 g) ADDITIONAL CHARGE FULL CHARGE 0.43 oz / ft. (4 0g/m ) SPECIFICA TIONS TYPE COOLING & HEA TING INDOOR UNIT MS36Y3F OUTDOOR UNIT MR36Y3F COOLING CAP ACITY 34,100 ...

  • Friedrich MS36Y3F - page 3

    OUTLINE AND DIMENSIONS 65-1/2" (1,660) 9-1/2" (240) 27-5/8" (700) 63" (1,600) 5-1/8" (130) 11-7/8" (300) Unit : inch (mm) INDOOR UNIT 2006.02.28 2 ...

  • Friedrich MS36Y3F - page 4

    Unit : inch (mm) OUTDOOR UNIT 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 2006.02.28 3 ...

  • Friedrich MS36Y3F - page 5

    Evaporator REFRIGERANT SYSTEM DIAGRAM OUTDOOR UNIT Pressure Check Valve Condenser 4-way Valve High Pressure Switch Accumulator Muffler Compressor Expansion Valve Refrigerant Pipe 9.52mm (3/8") Charging Valve Charging Valve Refrigerant Pipe 15.88mm (5/8") INDOOR UNIT Strainer Strainer : COOL : HEAT 2006.02.28 4 ...

  • Friedrich MS36Y3F - page 6

    CIRCUIT DIAGRAM INDOOR UNIT 2006.02.28 5 ORANGE YELLOW WHITE RED BROWN ORANGE YELLOW WHITE RED BROWN ORANGE YELLOW WHITE RED BROWN BLUE PURPLE GRAY GRAY PURPLE BLUE BLACK WHITE RED WHITE WHITE GREEN WHITE WHITE WHITE BLACK BLACK BLACK RED RED BLACK BLACK GRAY GRAY CN6 CN7 CN8 CN15 CN13 CN16 CN5 CN11 CN10 CN4 CN17 CN1 CN201 1 2 3 4 5 6 7 8 1 2 3 4 5 ...

  • Friedrich MS36Y3F - page 7

    OUTDOOR UNIT ORANGE YELLOW WHITE BLUE BROWN RED BLUE YELLOW WHITE BLACK RED BLACK BLACK RED RED BLUE BROWN BLACK BLACK BROWN RED GREEN BLACK BLACK WHITE WHITE WHITE BROWN BLACK BLACK RED BLACK WHITE ORANGE ORANGE BLACK RED YELLOW YELLOW BLUE ORANGE RED BROWN BROWN WHITE BLACK BLACK BLACK BLACK RED RED WHITE WHITE 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 1 ...

  • Friedrich MS36Y3F - page 8

    14V 5V R57 1.0K <1/10W> C39 0.1 <F> CR5 1000P <R> R50 10K <1/10W> R77 - R79 10K <1/10W> x 3 BZ1 PKM13EPY-4000 5V R21 - R24 10K <1/10W> x 4 5V 5V C22 - C25 0.01 <F> x 4 R25 - R28 1.0K <1/10W> x 4 I C6 (1/7) uPA2003GR R56 I C7 BR93LC46RF DO DI SK CS VCC NC NC GND 1 2 3 4 5 6 7 8 6 11 CN9-1 CN9-2 CN9-3 C ...

  • Friedrich MS36Y3F - page 9

    AC230V 60Hz TERMINAL HP-T3061-3 Model : MR36Y3F OUTDOOR PCB CIRCUIT DIAGRAM POWER SUPPL Y PCB K04BA-0501HUE-P0 CONTROLLER PCB ASSY K04A W-0504HUE-C1 INVERTER ASSY EZ-005HHUE 2006.03.13 8 ...

  • Friedrich MS36Y3F - page 10

    600/450V x 4 Model : MR36Y3F CONTROLLER PCB ASSEMBL Y ( MAIN PCB ) K04AW -0504HUE-C1 2006.02.28 9 ...

  • Friedrich MS36Y3F - page 11

    5V TM101 TM102 C1 12 0.015 <YE> C1 13 0.015 <YE> C1 1 1 3.3 <LE> L4 RCH4730-021PF07 C107 3.3 <LE> TM100 L2 N200500K1D7C CT1 CT -1B 5V D60 DAN217U C64 0.1 <F> R68 22K <1/10W> C65 0.1 <F> VR1 B2K + R61 3.74K <1/10W> (1%) C60 220/16V <PJ> R60 1.0K <1/10W> (1%) SA100 RA-302M C106 3.3 <LE> ...

  • Friedrich MS36Y3F - page 12

    ERROR CONTENTS (Indoor unit) Indoor EEPROM abnormal Outdoor EEPROM abnormal Indoor room temperature sensor open Indoor room temperature sensor shortcircuited Indoor heat exchanger temperature sensor open Indoor heat exchanger temperature sensor shortcircuited Float switch operated Indoor signal abnormal Outdoor signal abnormal Indoor fan abnormal O ...

  • Friedrich MS36Y3F - page 13

    SPECIAL INSTALLATION SETTING PUMP DOWN (Refrigerant collecting operation) ERROR CONTENTS (outdoor unit) 1. Make a TEST RUN in accordance with the in- stallation instruction sheet for the indoor unit. 2. OUTDOOR UNIT LEDS Error contents Communication error (Indoor unit - Outdoor unit) Discharg pipe temperature sensor Outdoor heat exchanger temperatu ...

  • Friedrich MS36Y3F - page 14

    DISASSEMBLY ILLUSTRATION INDOOR UNIT Model : MS36Y3F 345-2 240-2 240-1 876-1 345-1 338-1 338-2 8 403 122 286 174 386 138 752 735 329 321 69 684 435 434 228 229 580 506 407 505 408 361 396 160 63 868 743 240 146 383 762 74 448 472 223 755 56 388 164 403 181 761 174 387 12 382 379 109 126 122 286 384 2006.02.28 13 ...

  • Friedrich MS36Y3F - page 15

    407 434 435 408 505 506 69 876-1 387 160 91 91 91 321 386 361 Model : MS36Y3F 2006.02.28 14 ...

  • Friedrich MS36Y3F - page 16

    63 868 385 763 227 321 387 436 424 684 438 876-2 Model : MS36Y3F 2006.02.28 15 ...

  • Friedrich MS36Y3F - page 17

    253-3 34 195 253-4 253-5 253-6 253-7 236 234 380 185-1 625 187 472 448 223 381-4 253-2 253-1 875 815-1 195 Model : MS36Y3F 2006.02.28 16 ...

  • Friedrich MS36Y3F - page 18

    1 6 7 3 4 5 2 Model : MR36Y3F 2006.02.28 17 ...

  • Friedrich MS36Y3F - page 19

    17 18 10 13 9 15 14 8 Model : MR36Y3F 2006.02.28 18 ...

  • Friedrich MS36Y3F - page 20

    22 23 31 20 29 12 28 12 19 24 26 27 25 30 Model : MR36Y3F 2006.02.28 19 ...

  • Friedrich MS36Y3F - page 21

    37 38 33 34 36 35 Model : MR36Y3F 2006.02.28 20 ...

  • Friedrich MS36Y3F - page 22

    INDOOR UNIT 8 Air Filter 12 Base Assy Ref. Description Part No. Ref. Description Part No. 9359739005 9359680000 34 Capacitor 9900270216 56 Sirocco Fan Assy 63 Panel (Front) 69 Louver 74 Intake Grille 91 Hinge 109 Casing 122 Bearing-B Assy 126 Bracket (Motor) 138 Separate Wall 146 Evaporator Assy 160 Drain Pan Sub Assy 164 Fan Motor Assy-IN 174 Hang ...

  • Friedrich MS36Y3F - page 23

    OUTDOOR UNIT 1 T op Panel Sub Assy 2 Front Panel 3 Fan Guard 4 Grip Side 5 Service Panel Sub Assy 6 Right Panel Sub Assy 7 LABEL (FRIEDRICH) 8 Propeller Fan Assy 9 Motor , Induction 10 Condenser-A Assy 12 Strainer Assy 13 Separate Wall Assy 14 Cap Foot 15 Base Assy 17 3-W ay V alve Assy 18 3-W ay V alve Assy 19 Check Joint Assy 20 Compressor Assy 2 ...

  • Friedrich MS36Y3F - page 24

    ACCESSORIES Q'ty 1 2 1 2 1 1 Coupler heat insulator (large) Coupler heat insulator (small) Nylon fastener Special nut A (large flange) Special nut B (small flange) Installation template Auxiliary pipe assembly For indoor side pipe joint (Gas pipe) For indoor side pipe joint (Liquid pipe) For fixing the coupler heat insulator For installing ind ...

  • Friedrich MS36Y3F - page 25

    0602G3034 ...

Fabricante Friedrich Categoría Air Conditioner

Los documentos del dispositivo Friedrich MS36Y3F que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Friedrich
- manuales de instrucciones MS36Y3F
- hojas de producto Friedrich
- folletos informativos
- o etiquetas energéticas Friedrich MS36Y3F
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Friedrich MS36Y3F.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Friedrich MS36Y3F, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Friedrich MS36Y3F. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Friedrich MS36Y3F.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Friedrich MS36Y3F, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Friedrich MS36Y3F. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Friedrich MS36Y3F.

El manual de instrucciones completo de Friedrich debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Friedrich MS36Y3F - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Friedrich MS36Y3F, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Friedrich MS36Y3F que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Friedrich MS36Y3F - que deben facilitarnos los primeros pasos durante el uso de Friedrich MS36Y3F
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Friedrich MS36Y3F
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Friedrich MS36Y3F en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Friedrich MS36Y3F?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Friedrich MS36Y3F, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Friedrich MS36Y3F probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)