Manual de instrucciones Generac 04675-3

59 de páginas 5.99 mb
Descargar

Pasar a la página of 59

Summary
  • Generac 04675-3 - page 1

    PO WER SY STEMS, INC. ® Installation and Owner’ s Manual Air -cooled A utomatic Standb y Generators Models: 04673-2 (6 kW NG, 7 kW LP) 04674-2 (12 kW NG, 12 kW LP) 04675-3 (13 kW NG, 15 kW LP) D ANGER DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION ONL Y! Not intended for use as Primary P ower in place of utility or in life-suppor t applications. ...

  • Generac 04675-3 - page 2

    I NTRODUCTION Thank you for purchasing this model by Generac P ower Systems Inc.. This model is a compact, high performance, air - cooled, engine - driven generator designed to automatically supply electrical power to operate critical loads during a utility power failure. This unit is factory installed in an all-weather , metal enclosure that is in ...

  • Generac 04675-3 - page 3

    T able of Contents Air-cooled 7 kW, 1 2 kW and 15 kW Generators 1 Introduction ........................ Inside Front Cover Read This Manual Thoroughly ........................ IFC Contents .......................................................... IFC Operation and Maintenance ............................ IFC How to Obtain Service ................. ...

  • Generac 04675-3 - page 4

    2 Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual a n d w i t h t h e unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundame ...

  • Generac 04675-3 - page 5

    3 place before operating the generator . If work must be done around an operating unit, stand on an insulated, dry surface to reduce shock hazard. • Do not handle any kind of electrical device while standing in water , while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MA Y RESUL T . • The Nat ion al Ele ctr ica l Code ( ...

  • Generac 04675-3 - page 6

    D ANGER  Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations. 1.1 U N P ACKING/I NSP ECTION After unpacking, carefully inspect the contents for damage. • This standby generator set has been factory sup - plied with a weather protective enclosu ...

  • Generac 04675-3 - page 7

    Section 1 — General Information Air-cooled 7 kW, 1 2 kW and 15 kW Generators 5 1.4 TH E GEN ER A T OR Exh aust En c lo su r e Oi l Di p stic k D a t a D ecal C ontro l P a n el F uel Re g ulato r F uel Inl et G F CI O utle t O il Filte r Batter y Com p artmen t Exh aust En c lo su r e O il Filte r Batter y Com p artmen t F uel Inl et G F CI O utl ...

  • Generac 04675-3 - page 8

    6 Section 1 — General Information Air-cooled 7 kW, 1 2 kW and 15 kW Generators 1.5 SP E CI F ICA TIONS 1.5.1 GENER A T OR Model 04673 Model 04674 Model 0 4675 Rated Max. Continuous P ower 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP Capacity (W atts*) Rated V oltage 120/240 120/240 120/240 Rated Max. Continuous Load Current (Amps) 12 ...

  • Generac 04675-3 - page 9

    7 1.6 F U EL R EQUI R EM ENTS AN D R EC OM M EN D A TIONS W ith LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank. The engine has been fitted with a fuel carburetion system that meets the specifications of the 1997 California Air Resources Board for tamper -proof dual ...

  • Generac 04675-3 - page 10

    1. T urn off the gas supply . (if connected) 2. Open the roof and remove the door . 3. Remove the battery . (if installed) 4. Remove the engine air in baffle located on the left - hand side of the battery compartment. T wo M6 screws are located on top of the baffle and two M6 screws are located on the inside of the baffle towards the back. 5. Remov ...

  • Generac 04675-3 - page 11

    9 1.1 0 B A TTER Y I NS T ALL A TION Fill the battery with the proper electrolyte fluid if necessary and have the battery fully charged before installing it. Before installing and connecting the battery , complete the following steps: 1. Set the generator's A UTO/OFF/MANU AL switch to OFF . 2. T urn off utility power supply to the transfer swi ...

  • Generac 04675-3 - page 12

    10 The following procedures are to be observed: • Wear full eye protection and protective clothing; • Where electrolyte contacts the skin, wash it off immediately with water; • Where electrolyte contacts the eyes, immediately flush thoroughly with water and seek medical attention; and • Spilled electrolyte is to be washed down with an acid ...

  • Generac 04675-3 - page 13

    11 8. Connect an accurate AC voltmeter and a fre - quency meter across transfer switch terminal lugs E1 and E2. V oltage should be 242-252 volts; frequency should read about 61-63 Hertz. 9. Connect the AC voltmeter test leads across ter - minal lug E1 and neutral; then across E2 and neutral. In both cases, voltage reading should be 121-126 volts AC ...

  • Generac 04675-3 - page 14

    12 2.6 ADJ US TI NG TH E R EGU LA T OR (NA TUR AL GAS ON L Y) Although the generator has been factory set to pro - vide maximum power , it may be necessary in some areas to adjust this setting. Because natural gas has different BTU or power content across the country the engine may not perform as designed. If experiencing engine problems at high or ...

  • Generac 04675-3 - page 15

    13 Section 2 — Post Installation Start-up and Adjustments Air-cooled 7 kW, 1 2 kW and 15 kW Generators 6. When frequency is correct at no load, check the AC voltage reading . If voltage is incorrect, the volt- age regulator may require adjustment. Figure 2.3 — Single Cylinder Engine Governor Adjustment GO VERNOR SHAFT PRIMAR Y ADJUST SCREW GO V ...

  • Generac 04675-3 - page 16

    14 Section 3 — Operation Air-cooled 7 kW, 1 2 kW and 15 kW Generators NOTE: The voltage regulator is housed above the generator's control panel. The regulator maintains a voltage in direct proportion to frequency . F or example, at 62 Hertz, line -to -neutral voltage will be 124 volts. 3.1 B R EAK-I N P ROCEDU R E Once the unit has been inst ...

  • Generac 04675-3 - page 17

    15 Upon restoration of utility source voltage above a preset level, generator circuit board action signals the transfer switch to transfer loads back to that power supply . After retransfer , the engine is signalled to shut down. The actual sequence of operation is controlled by sensors and timers on a control logic circuit board, as follows: A. Ut ...

  • Generac 04675-3 - page 18

    16 D ANGER  Do not attempt to activate the transfer switch manually until all power voltage supplies to the switch have been positively turned off. Failure to turn off all power voltage supplies may result in extremely hazardous and possibly fatal electrical shock. 5. Use the manual transfer handle inside the trans - fer switch to move the main ...

  • Generac 04675-3 - page 19

    17 3.7 .3.1 Approximat e Crank Cycle Times • 15 seconds ON • 7 seconds OFF • 7 seconds ON • 7 seconds OFF • Repeat for 45 seconds Approximately 90 seconds total 3.7 .4 OVERSPEED This feature protects the generator from damage by shutting it down if it happens to run faster than the preset limit. This protection also prevents the gen- erat ...

  • Generac 04675-3 - page 20

    18 4.3 CHANGI NG TH E ENGI N E OI L 4.3.1 ENGIN E OI L R E COMM END A TIONS Use oil of American P etroleum Institute (API) Service Class SG, SH or SJ . Use all season SAE 5W -30 Synthetic oil. Organic break-in oil is required before using synthetic oil. NOTE: The unit is supplied with “break-in ” oil. See the “Break -in P rocedure,” Section ...

  • Generac 04675-3 - page 21

    19 Figure 4.7 — 12 kW and 15 kW Engine Air Cleaner Cover Filter Screw 4.6 SP AR K P L UG(S) Reset the spark plug(s) gap or replace the spark plug(s) as necessary . See Section 4.13 for mainte - nance requirements. 1. Clean the area around the base of the spark plug(s) to keep dirt and debris out of the engine. Clean by scraping or washing using a ...

  • Generac 04675-3 - page 22

    20 following procedur es are to be followed: • DO NOT SMOKE when near the battery; • DO NOT cause flame or spark in battery ar ea; and • Discharge static electricity from body before touch- ing the battery by first touching a grounded metal surface.  Be sure the AUTO/OFF/MANUAL switch is set to the OFF position before connecting the batter ...

  • Generac 04675-3 - page 23

    21  The exhaust from this product gets extremely hot and remains hot after shutdown. High grass, weeds, brush, leaves, etc. must remain clear of the exhaust. Such materials may ignite and burn from the heat of the exhaust system.  The maximum ambient temperature for the generator is 48.9° C (104° F). 4.1 0 A TTENTION AF TER SU B M ERSION If ...

  • Generac 04675-3 - page 24

    22 Section 4 — Maintenance Air-cooled 7 kW, 1 2 kW and 15 kW Generators 4.1 3 SERVICE S CH EDU LE A TTENTION: It is recommended that all service work be performed by the nearest Authorized Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = W eekly R = Replace as Necessary M = Monthly * = Notify Dealer Y = Y early if ...

  • Generac 04675-3 - page 25

    23 Section 5 — T roubleshooting Air-cooled 7 kW, 1 2 kW and 15 kW Generators 5.1 TROU B LE SHOO TI NG GU I DE P ROB LEM CAUSE C OR R E CTION The engine will not crank. 1. F use blown 1. Replace 15A fuse on generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cables as necessary . 3. Defective starter conta ...

  • Generac 04675-3 - page 26

    24 Section 6 — Electrical Data Air-cooled 7 kW, 1 2 kW and 15 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D8500-B TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) 0 CUS T O MER SU PPLIE D BLA CK BATTERY 12V L OP HT O 0 S P 2 S P 1 IM2 86 85 IM1 D D DIA G RAM KE Y D S W - P C B M OU NTED DIP S WIT CH CB2 - CIRCU ...

  • Generac 04675-3 - page 27

    25 Section 6 — Electrical Data Air-cooled 7 kW, 1 2 kW and 15 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D8500-B C L OS E S T T O BEARIN G G R D 0 4 S TAT OR 1 94 224 224 22 5 1 5 224 17 4 22 5 224B 22 5 0 0 OU TP U T T O TRAN S FE R 22 22 MAN U A L F2 0 1 5A 66A 2 39 1 3 1 5 1 3 1 3 0 F1 1 5 17 17 V O LTA GE RE GU LAT OR 1 ...

  • Generac 04675-3 - page 28

    26 Section 6 — Electrical Data Air-cooled 7 kW, 1 2 kW and 15 kW Generators Electrical Schematic – 12 & 1 5 kW – Drawing No. 0D850 1-B IM1 - IGNITION MODULE , CYLINDER # 1 IM2 - IGNITION MODULE , CYLINDER # 2 L O P - L O W O IL PRE SSU RE S WIT CH SP1 , SP2 - SPARK PLUG S S W1 - A U T O / O FF / MAN U AL S WIT CH S W2 - S ET EXER C I S E ...

  • Generac 04675-3 - page 29

    27 Section 6 — Electrical Data Air-cooled 7 kW, 1 2 kW and 15 kW Generators Electrical Schematic – 12 & 1 5 kW – Drawing No. 0D850 1-B 2 39 IM2 1 5 1 8 S P 2 24 0V IM1 0 1 94 17 1 5 2 3 1 5 2 39 S W 1 1 94 1 5A 22 11 2 3 11 22 11 S P 1 44 WINDIN G 12 0V 12 0V 33 NEUTRAL N2 N1 2 3 CUS T O ME R CO NNE C TI O N S 1 94 0 0 SC F S 1 6 14 BATTE ...

  • Generac 04675-3 - page 30

    28 Section 6 — Electrical Data Air-cooled 7 kW, 1 2 kW and 15 kW Generators Wiring Diagram – 7 kW – Drawing No. 0D90 1 3-C TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) CB2 - CIRCUIT BREAKER , ALTERNATOR EXCITATIO N BLA CK CUS T O MER SU PPLIE D BATTERY 12V L OP HT O SP 86 85 IM D D S W - P C B M OU NTED DIP S WIT CH C B1 - M ...

  • Generac 04675-3 - page 31

    29 Section 6 — Electrical Data Air-cooled 7 kW, 1 2 kW and 15 kW Generators Wiring Diagram – 7 kW – Drawing No. 0D90 1 3-C 0 4 C L OS E S T T O BEARI N G R D S TAT OR OU TP U T T O TRAN S FE R 24 0 V G ENERAT OR S WIT C H CO NTA C T OR 8 2 0 66A 1 94 1 5 0 66A 1 5A 2 39 2 3 1 5 1 5A F2 1 3A 1 3 0 1 3 F1 1 3 351 14 N2 0 22 4 22 5 0 351 1 3 224 ...

  • Generac 04675-3 - page 32

    30 Section 6 — Electrical Data Air-cooled 7 kW, 1 2 kW and 15 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D901 4-C CB1 - CIRCUIT BREAKER , MAIN OUTPU T HT O - HI G H O IL TEMPERAT U RE S WIT CH S W1 - A U T O / O FF / MAN U AL S WIT CH CB2 - CIRCUIT BREAKER , ALT. EXCITATIO N TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUA ...

  • Generac 04675-3 - page 33

    31 Section 6 — Electrical Data Air-cooled 7 kW, 1 2 kW and 15 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D901 4-C INP UT 12V dc U TILIT Y CO I L RELAY TRAN S FE R NE U TRA L 120 V 24 0 VA C CUS T O ME R SU PPLIE D 2 3 S W 1 2 39 C 1- 6 0 1 5 17 0 1 8 C 1- 5 0 1 8 0 17 56 1 8 14 1 5A 17 0 1 5 0 C 1- 1 56 2 39 1 3 1 5 SC 14 1 5A 1 ...

  • Generac 04675-3 - page 34

    32 35 68 49 52 PRE PA C KA G ED U NIT S O NL Y 2 0 2 4 9 46 4 3 4 3 37 33 2 5 35 34 2 6 74 77 7 9 35 4 9 82 80 51 4 6 8 80 4 7 2 87 5 86 76 4 8 39 92 1 8 94 91 63 21 1 5 51 71 42 69 1 0 52 4 9 35 51 4 9 11 31 9 50 99 98 72 4 6 41 57 2 7 91 1 56 5 44 60 4 0 19 1 2 71 6 97 22 65 68 63 16 69 1 4 54 47 55 7 5 4 9 30 17 3 93 25 2 9 2 8 1 Section 7 — E ...

  • Generac 04675-3 - page 35

    33 ITEM P AR T NO . QTY . DESCRIPTION 1 0C6140 1 A SS EMBL Y , ENCLO S URE BA S E 0D1 9 01 1 A SS EMBL Y , ENCLO S URE BA S E (7KW) 2 0C67 3 5 2 S UPPORT , ROOF FOLDING 3 0F006 3 1 ENCLO S URE, FRONT 4 0C7062 1 ENCLO S URE, EXHAU S T S IDE 0C7062A 1 ENCLO S URE, EXHAU S T S IDE (7KW) 5 0 E 88 11 1 ENCLO S URE, S IDE & BACK 0 E 88 11A 1 ENCLO S ...

  • Generac 04675-3 - page 36

    34 31 19 3 7 38 22 8, 9 27 45 46 44 48 47 10 3 49 5 1 13 17 5 21 35 23 49 29 21 17 4 2 38 6 7 33 2 20 27 15 40 41 39 45 44 43 1 30 15 11 47 45 24 45 47 49 Section 7 — Exploded Views and P ar ts Lists Air-cooled 7 kW, 1 2 kW and 15 kW Generators Control Panel – Drawing No. 0E79 74-G ...

  • Generac 04675-3 - page 37

    35 ITEM P AR T NO . QTY . DESCRIPTION 1 0E7 88 6A 1 CIRCUIT BREAKER 3 0A X 2P 240V (7KW) 0 E 7 88 6C 1 CIRCUIT BREAKER 40A X 2P 240V ( 8 .5KW) 0 E 7 88 6D 1 CIRCUIT BREAKER 45A X 2P 240V (11KW) 0 E 7 88 6E 1 CIRCUIT BREAKER 50A X 2P 240V (12KW) 0 E 7 88 6F 1 CIRCUIT BREAKER 60A X 2P 240V (1 3 KW) 0 E 7 88 6G 1 CIRCUIT BREAKER 70A X 2P 240V (15KW) 2 ...

  • Generac 04675-3 - page 38

    36 14 3 47, 4 8 , 4 9 , 50, 51, 52, 5 3 , 54, 56, 57, 5 8 , 5 9 , 60, 62, 6 3 , 64 7, 47, 4 8 , 4 9 , 50, 51, 52, 5 3 , 54, 56, 57, 5 8 , 5 9 , 60, 6 3 , 64 144 5 3 46 4 8 47 4 9 50 51 52 40 38 41 42 2 8 45 44 4 3 2 9 14 3 39 3 7 26 27 3 3 1 24 140 3 2 3 3 5 55 33 3 6 20 57 1 9 5 8 5 9 61 60 64 62 6 3 65 1 2 6 3 , 3 2, 33 , 3 4, 3 5, 3 6, 40, 72 27 ...

  • Generac 04675-3 - page 39

    37 ITEM P ART NO . QTY . DESCRIPTION 1 0C572 9 1 A SS EMBL Y , CRANKCA S E HOU S ING WITH S LEEVE 2 0 E 98 4 3 1 S EAL, 38 I.D . CRANK S HAFT 3 0 9 0 388 3 S CREW , T APTITE M6-1.0 X 12 YC 4 0C5 3 72 1 A SS EMBL Y , BREA THER 5 0 C 3 005 1 GA S KE T , BREA THER COVER 6 0 E 33 72B 3 S EP ARA T OR, OIL BREA THER 7 0 D 8 067A 1 A SS EMBL Y , HEAD #1 G ...

  • Generac 04675-3 - page 40

    38 112 112 12 8 110 1 33 9 4 9 1 8 4 88 8 6 89 8 5 9 0 89 93 74 8 0 8 2 83 8 1 7 9 117 102 99 9 2 9 7 98 101 11 3 112 105 107 10 8 104 10 3 106 111 10 9 14 3 125 12 3 , 145 9 6 9 5 14 3 1 3 0 114 75 7 8 77 76 99 100 11 8 98 9 7 121 124 124 11 9 122 125 1 3 7 120 127 126 115 116 1 3 1 1 3 6 1 38 1 3 2 142 12 9 1 3 4 1 39 1 3 5 Section 7 — Exploded ...

  • Generac 04675-3 - page 41

    39 ITEM P AR T NO . QTY . DESCRIPTION 74 0C51 3 6A 2 KNOB, AIR CLEANER 7 5 0 C 3 024 1 COVER, AIRBO X NG/LP 7 6 0 C 3 040 1 PRE-CLEANER, 7 7 0 C 8 127 1 ELEMENT , AIR CLEANER 7 8 0 D 8 564A 1 A SS EMBL Y , MIXER/AIRBOX 99 0 0 D 8 564B 1 A SS EMBL Y , MIXER/AIRBO X 760 7 9 0D25 9 5 4 S CREW S HOULDER ( 8 MM) M6-1.0 X 1 8 8 0 0D4417 4 W A S HER,R UBB ...

  • Generac 04675-3 - page 42

    40 51 2 3 11 5 3 1 21 5 3 7 3 0 1 3 33 52 12 38 3 2 17 2 8 3 1 3 1 20 14 1 9 10 17 15 3 2 10 1 9 16 22 39 4 8 9 6 3 1 3 7 3 2 3 4 3 0 40 46 45 47 3 6 42 41 1 50 4 9 3 2 24 25 26 44 4 3 3 4 3 5 3 4 4 8 10 2 8 27 2 8 3 2 3 1 2 9 1 8 Section 7 — Exploded Views and P ar ts Lists Air-cooled 7 kW, 1 2 kW and 15 kW Generators 7 kW Generator – Drawing ...

  • Generac 04675-3 - page 43

    41 Section 7 — Exploded Views and P ar ts Lists Air-cooled 7 kW, 1 2 kW and 15 kW Generators 7 kW Generator – Drawing No. 0D35 04-E ITEM P AR T NO . QTY . DESCRIPTION 1 0C6 93 4 1 AD APT OR, ENGINE 2 0 C 993 5H 1 S TAT O R 3 0 C 993 4H 1 R O T OR 4 0C604 3 A 1 CARRIER, REAR BEARING 5 0 C 8 0 9 6 1 F AN, 8 " CUR VED B LADE 6 0 C 9 5 93 1 MU ...

  • Generac 04675-3 - page 44

    42 2 9 3 6 3 4 11 2 3 5 24 4 3 21 7 1 3 33 12 38 17 3 2 3 1 2 8 3 1 20 1 9 10 17 15 3 2 16 22 39 4 9 8 6 3 7 14 3 2 40 1 3 2 24 25 10 3 0 1 9 26 2 8 27 2 8 3 2 3 1 41 10 1 8 3 6 2 8 3 5 41 2 9 42 3 6 3 6 3 5 Section 7 — Exploded Views and P ar ts Lists Air-cooled 7 kW, 1 2 kW and 15 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D34 1 ...

  • Generac 04675-3 - page 45

    43 Section 7 — Exploded Views and P ar ts Lists Air-cooled 7 kW, 1 2 kW and 15 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D34 1 7 -L ITEM P AR T NO . QTY . DESCRIPTION 1 0C6 93 4 1 AD APT OR, ENGINE 2 0C7 93 0 1 S T A TOR 12KW 0D2 3 5 9 S TAT O R 1 3 KW / 15KW 3 0C7 9 44 1 ROT OR 12KW 0D2 3 56 ROT OR 1 3 KW / 15KW 4 0C604 3 1 CARR ...

  • Generac 04675-3 - page 46

    44 3 2 23 3 4 35 36 45 39 33 20 19 18 43 44 46 11 4 9 29 3 7 2 7 28 30 3 1 17 5 2 47 48 24 38 26 22 40 41 25 25 50 14 12 5 1 13 5 4 16 1 6 1 2 11 10 4 2 5 7 9 8 3 4 Section 7 — Exploded Views and P ar ts Lists Air-cooled 7 kW, 1 2 kW and 15 kW Generators GN4 1 0 Eng ine – Drawing No. 0F398 1 -A Part 1 ...

  • Generac 04675-3 - page 47

    45 ITEM P AR T NO . QTY . DESCRIPTION 1 0 E 3 221 1 A SS EMBL Y , CONNECTING ROD 2 0E1466 1 PIN, PI S T ON D20 3 0215 33 1 S ET , PI S TON RING 9 0MM 4 0 E 2 98 5 1 PI S T ON, HC 5 0 7 1 983 2 RET AINER, PI S TON PIN 20 6 0 E 8 440 1 A SS EMBL Y , CRANK S HAFT GH410 S MALL T APER 7 0A762 8 1 ARM, GO VERNOR RC45 8 0 7 8 65 8 1 PIN, "R" GOV ...

  • Generac 04675-3 - page 48

    46 19 20 41 43 21 6 40 3 39 28 4 24 6 1 2 7 6 1 14 18 17 27 3 1 30 2 45 5 13 8 5 2 6 11 9 48 42 1 0 25 26 18 3 2 18 3 4 6 3 4 33 6 3 7 Section 7 — Exploded Views and P ar ts Lists Air-cooled 7 kW, 1 2 kW and 15 kW Generators GN4 1 0 Eng ine – Drawing No. 0F398 1 -A Part 2 ...

  • Generac 04675-3 - page 49

    47 ITEM P AR T NO . QTY . DESCRIPTION 1 0C106 9 5 S CREW , T APTITE M6-1.0X 8 YELLO W CHROME 2 0D2 9 22 1 HOU S ING, BLO WER 3 0 C 8 4 3 5 1 TUBE, DIP S TICK 4 0 C 999 7 1 GUARD , F AN 5 0 88 4 3 4 1 WRAPPER, BO TT OM 6 045756 11 S CREW , T APTITE M6-1X10 YELLOW CHROME 7 0C4176A 1 WRAPPER, T OP 8 0 D 9 004A 1 A SS Y, S T ARTER 9 0 5 998 5 2 S CREW ...

  • Generac 04675-3 - page 50

    48 7KW 17 12 2 8 11 20 10 25 21 24 1 9 2 3 22 22 15 26 14 1 3 16 2 9 1 8 8 2 8 12 3 2 10 11 27 3 1 4 5 3 2 10 17 1 26 15 14 16 1 3 3 7 1 9 9 3 0 21 25 20 24 2 9 1 8 2 3 11 12 2 8 Section 7 — Exploded Views and P ar ts Lists Air-cooled 7 kW, 1 2 kW and 15 kW Generators Gas Regulator – Drawing No. 0D8 7 20-H ...

  • Generac 04675-3 - page 51

    49 ITEM P AR T NO . QTY . DESCRIPTION 1 0D56 9 4 1 CA S TING, TWIN REGULA TOR HOU S ING 2 0F5022 1 S OLENOID COIL, 12VDC 3 0C4647 1 GA S KET , S OLENOID 4 0D4166 1 PLUNGER, LP REGULA TOR A SS EMBL Y 5 0C6070 1 S PRING- S OLENOID , PLUNGER 8 0F47 9 5 4 S CREW PPHM S EM S M4-0.7 X 10 9 0C5760J 1 JET , GN 410 ENGINE LP (7KW) 10 0C6606 2* BARBED S TRAI ...

  • Generac 04675-3 - page 52

    TYPE HOM 120/240v CBHOM-F TYPE HOM CBHOM-F 120/240v TYPE HOM 120/240v CBHOM-F TYPE HOM 120/240v CBHOM-F TYPE HOM 120/240v CBHOM-F TYPE HOM CBHOM-F 120/240v TYPE HOM CBHOM-F 120/240v TYPE HOM CBHOM-F 120/240v TYPE HOM CBHOM-F 120/240v TYPE HOM CBHOM-F 120/240v TYPE HOM CBHOM-F 120/240v TYPE HOM CBHOM-F 120/240v M6PEM-T M6PEM-T M6PEM-T M6PEM-T REAR V ...

  • Generac 04675-3 - page 53

    51 Section 9 — Notes Air-cooled 7 kW, 1 2 kW and 15 kW Generators ...

  • Generac 04675-3 - page 54

    52 CALI FOR N IA EM ISSION C ONTROL W ARR ANT Y ST A TEMENT Y OUR W AR R ANT Y R IGHT S AN D OB LIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine. * In California, new utility , and lawn and garden equipment engines must be ...

  • Generac 04675-3 - page 55

    53 EM IS SION CONTROL SY STEM W ARR ANT Y Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines. The ECS W arranty P eriod shall begin on the date the new engine or equipment is purchased by/delivered to its original, end-use purchas ...

  • Generac 04675-3 - page 56

    Part No. 0F3983 Revision C (11/03/05) Printed in U.S.A . Section 1 0 – W arranty Air-cooled 7 kW, 1 2 kW and 15 kW Generators GENERA C PO WER SYSTEMS ST AND ARD TW O-YEAR LIMITED W ARRANTY FOR GENERA C RESIDENTIAL AND LIGHT COMMERCIAL UNITS For a per iod of two (2) years or two thousand (2,000) hours of operation from the date of sale, which e ve ...

  • Generac 04675-3 - page 57

    ERRATA SHEET ALL 8.5 kW THROUGH 15 kW HOME STAND-BY GENERATORS WITH GT-990/760 ENGINES 2/24/06 ! IMPORTANT INFORMATION ! THE SPARK PLUG GAP FOR ALL 8.5 kW THROUGH THE 15 kW HOME STAND-BY GENERATORS WITH THE GT-990/760 ENGINES SHOULD BE SET AT 1.02 mm (0.040 inch). THE RECOMMENDED SPARK PLUG IS CHAMPION #RC12YC (PART NO. 0G0767A). P/N: 0G0730 REV. A ...

  • Generac 04675-3 - page 58

    35 68 51 48 49 52 PRE PACKAGED UNITS ONLY 20 2 47 49 46 43 49 4 51 43 37 A 33 25 36 24 32 35 34 23 26 74 77 79 35 49 82 80 51 46 8 80 81 85 84 44 78 72 87 5 86 76 48 82 70 39 92 50 18 94 91 63 21 15 7 51 71 58 42 69 10 91 49 35 51 49 11 31 9 90 50 72 47 44 45 73 95 52 41 57 27 91 1 56 58 44 62 60 40 19 A 47 12 93 67 71 64 97 51 48 61 50 38 89 22 49 ...

  • Generac 04675-3 - page 59

    10 C 6 1 4 0 1 A S S E M B L Y , E N C L O S U R E B A S E 0D1901 1 ASSEMBLY, ENCLOSURE BASE (7KW) 20 C 6 7 3 5 2 S U P P O R T , R O O F F O L D I N G 30 F 0 0 6 3 1 E N C L O S U R E , F R O N T 40 C 7 0 6 2 1 E N C L O S U R E , E X H A U S T S I D E 0C7 06 2A 1 ENC LOS UR E, EX HA UST SIDE (7 KW) 5 0 F 0 0 6 6 1 E N C L O S U R E , S I D E & ...

Fabricante Generac Categoría Portable Generator

Los documentos del dispositivo Generac 04675-3 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Generac
- manuales de instrucciones 04675-3
- hojas de producto Generac
- folletos informativos
- o etiquetas energéticas Generac 04675-3
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Generac 04675-3.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Generac 04675-3, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Generac 04675-3. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Generac 04675-3.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Generac 04675-3, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Generac 04675-3. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Generac 04675-3.

El manual de instrucciones completo de Generac debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Generac 04675-3 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Generac 04675-3, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Generac 04675-3 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Generac 04675-3 - que deben facilitarnos los primeros pasos durante el uso de Generac 04675-3
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Generac 04675-3
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Generac 04675-3 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Generac 04675-3?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Generac 04675-3, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Generac 04675-3 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)