Manual de instrucciones American Dryer Corp. AD-50

66 de páginas 2.76 mb
Descargar

Pasar a la página of 66

Summary
  • American Dryer Corp. AD-50 - page 1

    AD-25, 30, 50, 75 and 758 Ser vice Manual Phase 7.2 Non-Coin American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 USA T elephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry .com www .amdry .com ADC Part No. 450268 ...

  • American Dryer Corp. AD-50 - page 2

    IMPORT ANT NO TE T O PURCHASER Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer . FOR Y OUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other ...

  • American Dryer Corp. AD-50 - page 3

    T able of Contents SECTION I IMPORT ANT INFORMA TION ........................... 4 A. Safety Precautions ............................................................ 4 SECTION II ROUTINE MAINTENANCE ............................... 5 A. Cleaning ............................................................................. 5 B. Adjustments .......... ...

  • American Dryer Corp. AD-50 - page 4

    4 American Dryer Corp. 450268-1 SECTION I IMPORT ANT INFORMA TION A. SAFETY PRECAUTIONS 1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any appliance. 2. Purchaser and user should consult the local gas supplier for proper instructions to be followed in the event the user smells gas. The instructions ...

  • American Dryer Corp. AD-50 - page 5

    450268-1 www .amdry .com 5 SECTION II ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating ...

  • American Dryer Corp. AD-50 - page 6

    6 American Dryer Corp. 450268-1 6 MONTHS Inspect and remove lint accumulation in the customer furnished exhaust ductwork system. Inspect exhaust draft dampers to ensure they are not binding. Inspect and remove ALL lint accumulation from in and around control box area including coin acceptors. Clean lint accumulation from around tumbler wrapper area ...

  • American Dryer Corp. AD-50 - page 7

    450268-1 www .amdry .com 7 SECTION III INST ALLA TION REQUIREMENTS Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National S tandards: ANSI Z223.1-LA TEST EDITION (National Fuel Gas Code) or ANSI/NFP A NO. 70-LA T ...

  • American Dryer Corp. AD-50 - page 8

    8 American Dryer Corp. 450268-1 B. ELECTRICAL AND GAS REQUIREMENTS 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and st ate regulations or codes. In the absence of such codes, A ...

  • American Dryer Corp. AD-50 - page 9

    450268-1 www .amdry .com 9 C. OPERA TIONAL SER VICE CHECK PROCEDURE After performing any service or maintenance function, an operational check should be performed to ensure that ALL components are performing properly . 1. Make a complete operational check of ALL the operating controls to assure that the timing is correct, temperature selection swit ...

  • American Dryer Corp. AD-50 - page 10

    10 American Dryer Corp. 450268-1 SECTION IV DESCRIPTION OF PAR TS A. CONTROL PANEL (MICROPROCESSOR) Lifting the control door will reveal the control p anel assembly . Opening the control panel will allow access to the major components, which include the computer board, and keypad. The keypad inputs to the computer what temperature and program has b ...

  • American Dryer Corp. AD-50 - page 11

    450268-1 www .amdry .com 11 D. LINT DRA WER SWITCH The lint drawer switch is located in the lint comp artment and attached to the side of the lint drawer track. The lint drawer switch ensures that the dryer will operate only when the lint drawer is completely close. This is a safety device and should never be disabled. E. LINT DRA WER The lint draw ...

  • American Dryer Corp. AD-50 - page 12

    12 American Dryer Corp. 450268-1 G . TUMBLER BEARING AND PULLEY ARRANGEMENT The tumbler bearing and the pulley arrangement is located (viewing from the rear of the dryer) approximately at the upper center of the dryer . The arrangement consists of a pulley , bearing platform, and bearing, which serve to adjust, drive, and support the tumbler . H . ...

  • American Dryer Corp. AD-50 - page 13

    450268-1 www .amdry .com 13 J. TEMPERA TURE SENSOR (COMPUTER CONTROLS) The temperature sensor used, is a transducer that converts heat into microamp s that the computer board then uses to calculate the temperature. K. GAS BURNER Gas dryers are equipped with a gas burner located behind the control door . The gas burner assembly consists of the burne ...

  • American Dryer Corp. AD-50 - page 14

    14 American Dryer Corp. 450268-1 M. COMPRESSED AIR REQUIREMENTS This dryer requires an external supply of air (2.5 cfm @ 80 psi [0.07 cmm @ 5.51 bar]) on the steam models, the air is necessary to operate the steam damper system. On both steam, as well as the gas model, the air is necessary for the blower air jet operation to clean lint from the imp ...

  • American Dryer Corp. AD-50 - page 15

    450268-1 www .amdry .com 15 P . MOT OR CONT ACT OR (1Ø MOT OR) This motor contactor used on a single-phase (1ø) dryer , is located in the rear of the dryer , in the electrical panel box. It s purpose is to transfer the higher voltage to the motor , when the contactor coil voltage has been achieved. Q. NON-REVERSING CONT ACT OR (3Ø MOT OR) The no ...

  • American Dryer Corp. AD-50 - page 16

    16 American Dryer Corp. 450268-1 S. HI-LIMIT THERMOST A T (GAS AND ELECTRIC MODELS ONL Y) The hi-limit thermostat is another safety device that we use on gas and electric models. The hi-limit is located in the burner or oven area. The hi-limit switch cuts of f the heat, if the temperature exceeds 290° for electric models or 330º for gas models. T ...

  • American Dryer Corp. AD-50 - page 17

    450268-1 www .amdry .com 17 SECTION V SER VICING IMPORT ANT: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OCCUP A TIONAL SAFETY AND HEAL TH ADMINISTRA TION (OSHA) ST ANDARDS. ...

  • American Dryer Corp. AD-50 - page 18

    18 American Dryer Corp. 450268-1 TO REPLACE COMPUTER 1. Discontinue power to the dryer . 2. Disconnect the J3, J4, J5, J6, and J8 harnesses from the rear of the computer by squeezing the top locking tab and pulling the connector straight back. 3. Disconnect the green ground wire from the computer . 4. Disconnect the keypad ribbon from the computer ...

  • American Dryer Corp. AD-50 - page 19

    450268-1 www .amdry .com 19 TO REPLACE COMPUTER TEMPERA TURE SENSOR PROBE 1. Discontinue power to the dryer . 2. Remove microprocessor sensor bracket assembly from the dryer . a. Disconnect sensor bracket harness connector . b. Loosen the two (2) Phillips head screws securing the bracket assembly to the dryer and remove the bracket from the dryer . ...

  • American Dryer Corp. AD-50 - page 20

    20 American Dryer Corp. 450268-1 B. BURNER CONTROLS (GAS) This illustration is typical of ALL gas burners, but they are not ALL exactly alike. Y our particular model may have some differences. TO REPLACE SP ARK IGNITOR 1. Discontinue power to the dryer . 2. Disconnect high voltage connector and flame-probe connection from ignitor . 3. Disassemble i ...

  • American Dryer Corp. AD-50 - page 21

    450268-1 www .amdry .com 21 TO REPLACE GAS V AL VE 1. Discontinue power to the dryer . 2. Close shutoff valve in the gas supply line. 3. Disconnect the gas valve wiring. 4. Break union connection before gas valve. 5 . Loosen and remove two (2) screws securing pipe bracket to the burner . 6. Remove gas valve/manifold assembly from the dryer . 7. Rem ...

  • American Dryer Corp. AD-50 - page 22

    22 American Dryer Corp. 450268-1 NOTE: Manometers are available from the factory by ordering ADC Part No. 122804. 1. T o test gas water column (W .C.) pressure. a. Connect water column test gauge connection to gas valve pressure t ap (1/8” N.P .T). This pressure tap is located on the outlet (downstream) side of the valve. b. S tart the dryer . Wi ...

  • American Dryer Corp. AD-50 - page 23

    450268-1 www .amdry .com 23 TO CONVERT FROM NA TURAL T O LIQUID PROP ANE (L.P .) GAS 1. Disconnect electrical power to the dryer . 2. Close ALL shutof f valves in dryer gas supply line. 3. Disconnect gas valve wiring. NOTE: Identify location of each wire for correct reinstallation. 4. Break union connection (nut) between union shutoff and gas valve ...

  • American Dryer Corp. AD-50 - page 24

    24 American Dryer Corp. 450268-1 TO REPLACE BURNER TUBES 1. Discontinue power to the dryer . 2. Close shutoff valve in the gas supply line. 3. Disconnect the gas valve wiring. 4. Break union connection before gas valve. 5 . Loosen and remove two (2) screws securing the gas valve bracket to the burner . 6. Remove gas valve/manifold assembly from the ...

  • American Dryer Corp. AD-50 - page 25

    450268-1 www .amdry .com 25 C. STEAM CONTROLS INST ALLA TION Piping must be inst alled in accordance with good commercial steam system practice. Refer to the illustration below for a typical pipe arrangement. STEAM DAMPER SYSTEM MAN0582 ...

  • American Dryer Corp. AD-50 - page 26

    26 American Dryer Corp. 450268-1 TO REPLACE STEAM COIL (DAMPER SYSTEM) 1. Discontinue power to the dryer . 2. Remove the four (4) lock washers and hex nuts securing the hinges to the steam coil. 3. Remove hinges from the steam coil housing (these will be used on the new assembly). 4. Remove six (6) washers and hex nuts securing steam coil to the dr ...

  • American Dryer Corp. AD-50 - page 27

    450268-1 www .amdry .com 27 TO REPLACE THE NEEDLE V AL VE 1. Discontinue power to the dryer . 2. Discontinue the air to the dryer . 3. Remove the 1/8” brass close nipple from the needle valve. 4. Remove the 1/8” M.P .T . connector from the needle valve. 5. Remove the needle valve. 6. Reverse procedure to install the new needle valve. TO REPLACE ...

  • American Dryer Corp. AD-50 - page 28

    28 American Dryer Corp. 450268-1 D. ELECTRICAL OVEN CONTROLS TO REPLACE ELECTRICAL ELEMENTS 1. Discontinue power to the dryer . 2. Remove cover by removing two (2) screws and lifting the cover . 3. Remove the screws and wiring holding the element in place at the rear of the oven. 4. From the front of the oven, slide out element. 5 . Reverse procedu ...

  • American Dryer Corp. AD-50 - page 29

    450268-1 www .amdry .com 29 E. THERMOST A TS AND TEMPERA TURE SENSOR TO REPLACE HI-LIMIT THERMOST A T (330º GAS, 290º ELECTRIC) This thermostat is an import ant safety device serving as an added protection against failure of the air sail switch to open in the event of motor failure or reduced airflow condition. IMPORT ANT : UNDER NO CIRCUMST ANCE ...

  • American Dryer Corp. AD-50 - page 30

    30 American Dryer Corp. 450268-1 2. T emperature Sensor (Microprocessor Models) a. Discontinue power to the dryer . b. Open and remove the lint door . c. Disconnect sensor bracket harness connector . d. Loosen the two (2) Phillips head screws securing bracket assembly to dryer and remove by sliding bracket towards the rear of the dryer . e. Disasse ...

  • American Dryer Corp. AD-50 - page 31

    450268-1 www .amdry .com 31 TO ADJUST SAIL SWITCH 1. Operate the installed dryer normally to verify that the heat system is fully operational. 2. Open the main dryer door . 3. Manually depress the door switch actuator . 4. While continuing to depress the door switch actuator , and with the door open, start the dryer . 5. If the heat system is not a ...

  • American Dryer Corp. AD-50 - page 32

    32 American Dryer Corp. 450268-1 TO REPLACE MAIN DOOR ASSEMBL Y 1. Remove screws holding main door to main door hinge. 2. Reverse this procedure for reinstalling the new main door assembly . TO INST ALL NEW MAIN DOOR GLASS 1. Remove main door assembly from the dryer (follow main door removal procedure). 2. Lay main door on a flat surface with front ...

  • American Dryer Corp. AD-50 - page 33

    450268-1 www .amdry .com 33 5. Remove the screws securing the front panel to the dryer . 6. Gently remove the top right hand corner of the front panel assembly from the dryer . 7. Disconnect the main door switch harness at the connector . IMPORT ANT : When removing front panel assembly , be careful not to damage main door switch wires disconnected ...

  • American Dryer Corp. AD-50 - page 34

    34 American Dryer Corp. 450268-1 H. TUMBLER AND BEARING ASSEMBL Y (Remove back guard to access assembly) TO REPLACE TUMBLER PULLEY (NON-REVERSING) 1. Loosen V -belts, then rotate pulley and roll V -belts out of the grooves. 2. Loosen two (2) setscrews on the pulley and pull the pulley of f the shaft. 3. Reverse procedure for installing the new tumb ...

  • American Dryer Corp. AD-50 - page 35

    450268-1 www .amdry .com 35 TO REPLACE THE REAR TUMBLER BEARING 1. Remove the tumbler pulley (follow tumbler pulley removal procedure). 2. Remove the four (4) bolts securing the bearing platform to the back of the dryer . 3. Loosen Allen screw securing bearing collar to the shaft. 4. Slide bearing collar off the tumbler support. 5. Pull bearing pla ...

  • American Dryer Corp. AD-50 - page 36

    36 American Dryer Corp. 450268-1 I. IDLER AND BEARING ASSEMBL Y (Remove back guard to access assembly) TO REPLACE IDLER PULLEY 1. Remove the back guard. 2. Loosen V -belts, then rotate pulley and roll V -belts out of the grooves. 3. Loosen the two (2) setscrews on the pulley and pull of f the shaft. 4. Reverse procedure for installing the new idler ...

  • American Dryer Corp. AD-50 - page 37

    450268-1 www .amdry .com 37 J. DRIVE PULLEY (Remove back guard to access assembly) 1. Remove the back guard. 2. Loosen V -belts then rotate pulley and roll V -belts out of the grooves. 3. Loosen setscrews and pull motor pulley out. NOTE: If rust has developed on the shaft, use an emery cloth to polish the shaft. 4. Reverse procedure for installing ...

  • American Dryer Corp. AD-50 - page 38

    38 American Dryer Corp. 450268-1 TUMBLER ALIGNMENT (LA TERAL) 1. Discontinue power to the dryer . 2. Remove the back guard. 3. Loosen the two (2) hex head bolts, (one [1] turn is enough), that holds the pillow block bearing to the bearing box. 4. Back off the two (2) jam nut s on the side adjustment bolt s. Now , rotate the tumbler from the front o ...

  • American Dryer Corp. AD-50 - page 39

    450268-1 www .amdry .com 39 TO REPLACE THE TUMBLER AND/OR TUMBLER SUPPORT 1. Discontinue power to the dryer . 2. Remove the tumbler pulley . 3. Remove the front panel assembly . a. Open the control (service) door . b. Open the lint door . c. Remove the screws securing the front panel to the dryer . d. Gently remove the top right hand corner of the ...

  • American Dryer Corp. AD-50 - page 40

    40 American Dryer Corp. 450268-1 L. V -BEL TS (Refer to illustration in Sections I, J, and K) V -belts should have proper tension. If too loose, they will slip, if too tight excessive wear on the bearing will result. If the pulleys are not properly aligned, excessive belt wear will result. Proper belt tension will allow 1/2” displacement under no ...

  • American Dryer Corp. AD-50 - page 41

    450268-1 www .amdry .com 41 TO REPLACE V -BEL TS 1. Loosen tension on V -belts, so that they can easily be rolled off pulleys. 2. Replace V -belts. 3. Retighten V -belts and adjust tension and alignment per previous instructions. M. MOT OR TO REPLACE MOT OR (NON-REVERSING) 1. Discontinue power to the dryer . 2. Remove the drive belt. 3. Disconnect ...

  • American Dryer Corp. AD-50 - page 42

    42 American Dryer Corp. 450268-1 O. LINT DRA WER SCREEN TO REPLACE LINT SCREEN 1. Gently slide the lint drawer outward. 2. Remove the lint bag and inspect for rips or tears. Replace with new lint bag, if damaged. 3. Reverse procedure for installing the new lint bag. 4. Close the lint drawer . ...

  • American Dryer Corp. AD-50 - page 43

    450268-1 www .amdry .com 43 SECTION VI TROUBLESHOOTING The information provided will help isolate the most probable components associated with the dif ficulty described. The experienced technician realizes, however , that a loose connection or broken or shorted wire may be at fault where electrical components are concerned...not necessarily the sus ...

  • American Dryer Corp. AD-50 - page 44

    44 American Dryer Corp. 450268-1 PHASE 7 NON-COIN SYSTEM DIAGNOSTICS IMPORT ANT : YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y OR THE STEAM SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE T O ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OCCUP A TIONAL SAFETY AND ...

  • American Dryer Corp. AD-50 - page 45

    450268-1 www .amdry .com 45 BURNER PURGE FAUL T – The gas valve signal is present during the prepurge time. MODEL ERROR, ENTER CORRECT MODEL – The wrong model was selected for the dryer . EE PROM FAUL T ### – Error in memory location. The ### indicates the location of the fault. B. INPUT/OUTPUT BOARD LIGHT EMITTING DIODE (L.E.D.) INDICA T ORS ...

  • American Dryer Corp. AD-50 - page 46

    46 American Dryer Corp. 450268-1 2. Output s (Green L.E.D.) 9. AUX – This is for a spare output to be programmed. 10. STEAM – This light emitting diode (L.E.D.) will indicate the status of the steam injection output. If the request to turn on the steam injection is made, then the L.E.D. is ON. 1 1. _HEA T – This L.E.D. will indicate the statu ...

  • American Dryer Corp. AD-50 - page 47

    450268-1 www .amdry .com 47 A . The display reads “Exhaust High Limit Fault”. (Refer to p age 51) The temperature in the tumbler is above 220º F (104º C) or follow Steps #1 through #4 . 1. Check for voltage (24 V AC) at the computer on the J5 connector from pin 1 to ground. If no volt age is present, either you have a poor connection at the J ...

  • American Dryer Corp. AD-50 - page 48

    48 American Dryer Corp. 450268-1 E. The display reads “Sail Switch Closed Fault”. (Refer to page 52) 1. Prior to start up, the sail switch is in the closed position. 2. Check the sail switch and readjust accordingly . 3. Replace sail switch, if necessary . F . The display reads “Burner Ignition Control Fault”. (Refer to p age 52) 1. Check f ...

  • American Dryer Corp. AD-50 - page 49

    450268-1 www .amdry .com 49 H. Drive motor reverses, but does not go forward, blower motor runs. The display reads “Rot ation Fault”.* (Refer to p age 57) 1. Possible causes: a. Belt is broke, loose, or slipping. b. Lint accumulation on the rot ational sensor . c. Rotational sensor magnet is missing or broke. Reset power , then, restart the dry ...

  • American Dryer Corp. AD-50 - page 50

    50 American Dryer Corp. 450268-1 J. No display condition or display reads “Low V oltage Fault”.* (Refer to p age 54) 1. Check for line voltage (120, 208, 240, etc.) in the rear of the dryer at the distribution block. If no voltage is present, the problem may be a faulty or tripped breaker . If voltage is present, check for line voltage (120, 20 ...

  • American Dryer Corp. AD-50 - page 51

    450268-1 www .amdry .com 51 ...

  • American Dryer Corp. AD-50 - page 52

    52 American Dryer Corp. 450268-1 ...

  • American Dryer Corp. AD-50 - page 53

    450268-1 www .amdry .com 53 ...

  • American Dryer Corp. AD-50 - page 54

    54 American Dryer Corp. 450268-1 ...

  • American Dryer Corp. AD-50 - page 55

    450268-1 www .amdry .com 55 ...

  • American Dryer Corp. AD-50 - page 56

    56 American Dryer Corp. 450268-1 ...

  • American Dryer Corp. AD-50 - page 57

    450268-1 www .amdry .com 57 ...

  • American Dryer Corp. AD-50 - page 58

    58 American Dryer Corp. 450268-1 SECTION VII DA T A LABEL INFORMA TION A. DA T A LABEL When contacting ADC , certain information is required to ensure proper service/p arts information from ADC . This information is on the data label af fixed to the left side panel/wall area behind the control door . When contacting ADC , please have the model numb ...

  • American Dryer Corp. AD-50 - page 59

    450268-1 www .amdry .com 59 B. USING A MANOMETER HOW TO USE A MANOMETER 1. With dryer in nonoperating mode, remove plug on the gas valve pressure tap. 2. Install 1/8” N.P .T . fitting supplied with the manometer . 3. Attach plastic tubing to pressure tap fitting. 4. Attach manometer to dryer using magnet. NOTE: Place manometer in a position so th ...

  • American Dryer Corp. AD-50 - page 60

    60 American Dryer Corp. 450268-1 C. KEYP AD LA YOUT 1. Dot Matrix Display 2. A-F Preprogrammed Cycles 3. S top/Pause Button 4. S tart Button 5. Increment Button 6. Decrement Button 7. One time Auto (Dryness level) and Manual (T imed) Cycle NOTE: Fuse 1 is for computer power rated at 1/2-Amp. If fuse blows, it is a computer board fault. Fuse 2 is fo ...

  • American Dryer Corp. AD-50 - page 61

    450268-1 www .amdry .com 61 D. SENSOR ACTIV A TED FIRE EXTINGUISHING (S.A.F .E.) SYSTEM THEORY OF OPERA TION While the dryer is in an idle state or 20-seconds af ter the heat turns of f, the Phase 7 control monitors the S.A.F .E. system probe located in the top of the tumbler chamber and records the minimum temperature. If the minimum recorded S.A. ...

  • American Dryer Corp. AD-50 - page 62

    62 American Dryer Corp. 450268-1 E. ST A TIC PRESSURE The pressure of the air in sheet metal duct s is of great importance for safe and efficient operation of the dryer . The air pressures, as small as they are, have a large influence upon the performance of the dryer . There are three (3) pressures present within a duct. The velocity pressure, whi ...

  • American Dryer Corp. AD-50 - page 63

    450268-1 www .amdry .com 63 F . USING A MAGNEHELIC When measuring such small air pressures, the U-tube is often not accurate enough. Such small dif ferences in pressure are most often measured by an inclined tube manometer or a Magnehelic pressure gage as shown in Illustration #2 . ILLUS. #2 For convenience and accuracy , an instrument known as a P ...

  • American Dryer Corp. AD-50 - page 64

    64 American Dryer Corp. 450268-1 T o obt ain the most accurate static pressure readings of a dryer , the following guidelines should be conformed to. The reading should be taken in a straight section of duct, a minimum of ten (10) times the diameter of the duct (i.e. 10-inches [25.4 cm] diameter duct, a straight section 100-inches [254 cm] in lengt ...

  • American Dryer Corp. AD-50 - page 65

    450268-1 www .amdry .com 65 Notes _____________________________________________________________________________________________ ___________________________________________________________________________________________________ ___________________________________________________________________________________________________ ______________________ ...

  • American Dryer Corp. AD-50 - page 66

    ADC Part No. 450268 1 - 10/26/05 - 0 ...

Fabricante American Dryer Corp. Categoría Clothes Dryer

Los documentos del dispositivo American Dryer Corp. AD-50 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos American Dryer Corp.
- manuales de instrucciones AD-50
- hojas de producto American Dryer Corp.
- folletos informativos
- o etiquetas energéticas American Dryer Corp. AD-50
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones American Dryer Corp. AD-50.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje American Dryer Corp. AD-50, instrucciones de servicio, instrucciones cortas o instrucciones de usuario American Dryer Corp. AD-50. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto American Dryer Corp. AD-50.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo American Dryer Corp. AD-50, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar American Dryer Corp. AD-50. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de American Dryer Corp. AD-50.

El manual de instrucciones completo de American Dryer Corp. debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual American Dryer Corp. AD-50 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice American Dryer Corp. AD-50, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de American Dryer Corp. AD-50 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo American Dryer Corp. AD-50 - que deben facilitarnos los primeros pasos durante el uso de American Dryer Corp. AD-50
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con American Dryer Corp. AD-50
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de American Dryer Corp. AD-50 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de American Dryer Corp. AD-50?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con American Dryer Corp. AD-50, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con American Dryer Corp. AD-50 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)