    IMPORT ANT : TO THE INST ALLER. It is the responsibility of the Installer to ensure that the water supply to the dispensing equipment is provided with protection against backflow by an air gap as defined in ANSI/ASME A1 12.1.2-1979; or an approved vacuum breaker or other such method as proved effective by test. W ater pipe connections and fixtures ...

  • Cornelius UCR 700 Series - page 2

    i 630460127 T ABLE OF CONTENTS Page SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RECOGNIZE SAFETY INFORMA TION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UNDERST AND SIGNAL WORDS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius UCR 700 Series - page 3

    ii 630460127 T ABLE OF CONTENTS (cont ’ d) Page UPPER NUT AND BEARING ASSEMBL Y 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TO REPLACE BEARING 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ELECTRICAL CHECKOUT 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius UCR 700 Series - page 4

    1 6630460154 SAFETY INFORMA TION Recognize Safety Information This is the safety-alert symbol. When you see this symbol on our machine or in this manual, be alert to the potentially of personal injury . Follow recommended precautions and safe operating practices. CAUTION DANGER Understand Signal Words A signal word - DANGER, W ARNING, OR CAUTION is ...

  • Cornelius UCR 700 Series - page 5

    2 630460154 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius UCR 700 Series - page 6

    3 630460154 GENERAL DESCRIPTION T O THE USER OF THIS MANUAL This manual covers the installation and assembly of the Air – Cooled or W ater – Cooled Model UC700 Icemaker with the Model UC150 Dispenser . Refer to T able of Contents for page location of detailed information pertaining to questions that may arise during installation or operation of ...

  • Cornelius UCR 700 Series - page 7

    4 630460154 T able 1. Design Data (cont ’ d) W ater Supply – W ater inlet fitting is 1/4 – inch SAE flare located at the top front of the Unit. The Unit is designed to operate on water pressure between 10 PSI and 90 PSI. Drain Overflow Line (Located at rear of the Unit) 3/8 – inch Flexible T ubing Ambient Operating T emperature 40 ° F to 1 ...

  • Cornelius UCR 700 Series - page 8

    5 630460154 FIGURE 1. CLEARANCE REQUIREMENTS ...

  • Cornelius UCR 700 Series - page 9

    6 630460154 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius UCR 700 Series - page 10

    7 630460154 INST ALLA TION PRE – INST ALLA TION Freight Damage Claim The delivery of your equipment (Frieght Company , Distributor , or dealer) is responsible for loss or damage of your shipment. All claims must be filed with the deliverer of your equipment. Please follow the steps below to determine if your shipment is satisfactory or if a claim ...

  • Cornelius UCR 700 Series - page 11

    8 630460154 INST ALLA TION 1. Keep unit in the upright position, remove carton and pallet from the Icemaker and inspect for damage. If any damage is found, file a claim with carrier immediately . 2. Locate startup card either on outside of container or on plastic liner . Fill in proper information and send one to factory , and other copy to distrib ...

  • Cornelius UCR 700 Series - page 12

    9 630460154 INITIAL ST ART UP , CHECKS AND ADJUSTMENT INSTRUCTIONS NOTE: Do not start Icemaker before completing installation steps on pages 7 and 9. T urn on water supply (if Icemaker is water cooled turn water on to condenser also) turn on main power switch (located on top of electrical box), and make the following system checks: NOTE: If Icemake ...

  • Cornelius UCR 700 Series - page 13

    10 630460154 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius UCR 700 Series - page 14

    11 630460154 GUIDE T O SER VICE W ARNING: Disconnect electrical power to the Icemaker to prevent personal injury before attempting any internal maintenance. Only qualified personnel should service internal components or electrical wiring. ICEMAKER CLEANING AND SANITIZING PROCEDURES Do not use any of the ice made during cleaning operations. Clean an ...

  • Cornelius UCR 700 Series - page 15

    12 630460154 Semi – Annually Semi-Annually in addition to all previously established service procedures perform the following: 1. Check for water leaks in tube connections, water fittings and lower Icemaker water seal. 2. Check drain tubes for clogs and aged tubes. Replace if tubes are stained or brittle. 3. Check for signs of condensation. Clean ...

  • Cornelius UCR 700 Series - page 16

    13 630460154 3. The transparent bowl not only provides a visible check of water level, but also is a good guide to the inter- nal conditions which exist within the icemaker assembly itself. (See Cleaning Procedure.) T o Replace W ater Level Control 1. Shut off the water supply . Shut off the main power switch or unplug the ice dispenser from electr ...

  • Cornelius UCR 700 Series - page 17

    14 630460154 EXP ANSION V AL VE Y ou will find a thermostatic expansion valve on icemakers, which is used to control the amount of refrigerant flowing through the evaporator . Improperly installed or defective expansion valves may cause low production, soft ice, squeaking from evaporator and excessive load inside evaporator . By using general refri ...

  • Cornelius UCR 700 Series - page 18

    15 630460154 FIGURE 5. EXP ANSION V AL VE FIGURE 6. ADJUSTMENT SCREW THERMOST A TIC EXP ANSION V AL VE SIGHT GLASS CONDENSER MODULA TING V AL VE REMOV AL 1. Disconnect power to unit, then shut off water supply to condenser and evacuate refrigerant from system. 2. Remove inlet water line from Condenser Modulating V alve. Also remove tube from high s ...

  • Cornelius UCR 700 Series - page 19

    16 630460154 GEARMOT OR The gearmotor is equipped with a start relay and a manual reset overload. When current is applied, the relay energizes and completes the circuit to the start winding. The motor reaches a predetermined speed and the relay drops out, disconnecting the start winding. The run winding remains in the circuit as long as current is ...

  • Cornelius UCR 700 Series - page 20

    17 630460154 ST ART RELA Y 1. Check between “ 2 ” and “ 4 ” on relay (with relay unplugged). If there is continuity replace the relay , as the relay contacts should be open. 2. Check between “ 3 ” and “ 4 ” on relay , if no continuity replace the relay . FIGURE 7. GEARMOTOR ASSEMBL Y T O REPLACE GEARMOTOR ASSEMBL Y 1. Disconnect the ...

  • Cornelius UCR 700 Series - page 21

    18 630460154 AUGER AND EXTRUDING HEAD REMOV AL 1. Disconnect unit from power supply . 2. Remove storage container cover and put aside. 3. T urn off water supply to icemaker . 4. After ice has melted from head take hold of the auger nut and lift straight up to disengage from icemaker . 5. When replacing the auger assembly , make certain that both th ...

  • Cornelius UCR 700 Series - page 22

    19 630460154 3. Remove Dispense T ray Cover . 4. Use an open end wrench on auger nut connected to bearing and turn counterclockwise to remove assembly . 5. Remove worn bearings. Replace with new bearings and then reinstall assembly . NOTE: If auger turns with nut, remove cover on top of gearmotor stator and hold motor while loosen- ing nut. FIGURE ...

  • Cornelius UCR 700 Series - page 23

    20 630460154 FIGURE 12. GEAR MOTOR OVERLOAD SAFETY CONTROLS Y our icemaker unit has several safety and control devices incorporated into its design. W ARNING: None of the below described devices should ever be “ bypassed ” to allow the unit to function. The safety and control system shut-off devices are: 1. Low water shut off reed switch locate ...

  • Cornelius UCR 700 Series - page 24

    21 630460154 GUIDE TO GOOD ICE CUSTOMER COMMENTS CHECK ICEMAKER LOCA TION CONDITIONS FIRST CHECK ICE MAKER S Use gauges for checking suction and head pressures. See manual for correct reading and conditions. Check frost line and sight glass. S Check water level for proper adjustment and restrictions. See Manual. S Check evaporator assembly for worn ...

  • Cornelius UCR 700 Series - page 25

    22 630460154 FIGURE 13. WIRING DIAGRAM ...

  • Cornelius UCR 700 Series - page 26

    23 630460154 TROUBLESHOOTING CHART – ICEMAKER NOT OPERA TING NO POWER Check electrical wiring in con- trol box for loose connec- tions. Check for failed service switch or relay . Check power to machine. ICEMAKER RUNS BUT DOES NOT MAKE ICE Condenser fan running but compressor not running Check line voltage. Check compressor winding & component ...

  • Cornelius UCR 700 Series - page 27

    24 630460154 TROUBLESHOOTING IMPORTANT : Only qualified personnel should service internal components or electrical wiring. TROUBLESHOOTING COMPRESSORS T rouble Probable Cause Remedy Basically the compressor problems can be narrowed down to three areas of checkout. THE COMPRESSOR WILL NOT RUN A. No voltage to the compressor terminals. A. Check circu ...

  • Cornelius UCR 700 Series - page 28

    630460154 25 P ARTS LIST ...

  • Cornelius UCR 700 Series - page 29

    26 630460154 FIGURE 14. P ANEL COMPONENTS 2 1 7 1 14 16 20 1 17 15 18 19 1 5 12 9 8 10 11 13 6 Item No. Part No. Name 1 07578 Thread Cutting Screw , Phil T russ Hd. No. 8 – 32 X 3/8 – in long 2 630000806 Panel T op 3 4 5 630000808 Panel, Left – Hand 6 630000807 Panel, Right – Hand 7 630201094 Panel, Back 8 161 176000 W asher , Flat, .250 I. ...

  • Cornelius UCR 700 Series - page 30

    630460154 27 Item No. Part No. Name Ice Chute Components 1 38220 Machine Screw , 1/4-20 2 630000741 Elbow , Ice Chute 3 630250106 T ube, Ice Transfer 4 630900564 O-Ring, 4.234 I.D. 5 630900608 Head, Extruder 6 638090213 Auger 7 638090219 Bearing, Nylon 8 638090220 Bearing, Delrin 9 63809021 1-002 Auger Nut 1 2 3 4 5 6 7 8 9 FIGURE 15. ICE CHUTE COM ...

  • Cornelius UCR 700 Series - page 31

    28 630460154 Item No. Part No. Name Compressor Com ponents 1 164154001 Washer , Flat, >375 I.D. 2 165596002 Grommet 3 168770002 Machine Screw , Hex Hd, 5/16-18 By 1 1/2-In. Long 4 631500018 Compressor Kit 5 638007972-02 Hex Washer Hd, No. 10 By 1/2-In. Long 1 2 3 4 5 FIGURE 18. COMPRESSOR COMPONENTS Item No. Part No. Name Front End Components 1 ...

  • Cornelius UCR 700 Series - page 32

    630460154 29 Item No. Part No. Name Evaporator Com ponents 1 630200737 Bracket 2 630900558 Adaptor , Front End Ass ’ y 3 630900559 Gasket, Front End Ass ’ y 4 630900572 O-Ring, 4.1 I.D. 5 630900635 Machine Screw , Hex Hd, 1/4-20 By 1 3/4-In. Long 6 638001662 Insulator , Switch 7 638003924 Switch 8 638007009-10 Screw , No. 6 By 1 1/4-In. Long 9 ...

  • Cornelius UCR 700 Series - page 33

    30 630460154 IMI CORNELIUS CER TIFICA TE OF W ARRANTY TWO YEAR LIMITED ICE EQUIPMENT W ARRANTY IMI Cornelius warranty to the original commercial purchaser/user , that any commercial product of its manufacture bearing the name Cornelius will be free from defect in material and/or factory w ork- manship, and that if properly installed, maintained, an ...

  • Cornelius UCR 700 Series - page 34

    31 630460127 THIS P AGE LEFT BLANK INTENTIONALL Y ...

  • Cornelius UCR 700 Series - page 35

    One Cornelius Place Anoka, Minnesota 55303-6234 T elephone (800) 238-3600 Facsimile (763) 422-3246 Corporate Headquarters: IMI CORNELIUS INC. ...

Fabricante Cornelius Categoría Ice Maker

Los documentos del dispositivo Cornelius UCR 700 Series que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Cornelius
- manuales de instrucciones UCR 700 Series
- hojas de producto Cornelius
- folletos informativos
- o etiquetas energéticas Cornelius UCR 700 Series
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Cornelius UCR 700 Series.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Cornelius UCR 700 Series, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Cornelius UCR 700 Series. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Cornelius UCR 700 Series.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Cornelius UCR 700 Series, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Cornelius UCR 700 Series. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Cornelius UCR 700 Series.

El manual de instrucciones completo de Cornelius debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Cornelius UCR 700 Series - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Cornelius UCR 700 Series, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Cornelius UCR 700 Series que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Cornelius UCR 700 Series - que deben facilitarnos los primeros pasos durante el uso de Cornelius UCR 700 Series
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Cornelius UCR 700 Series
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Cornelius UCR 700 Series en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Cornelius UCR 700 Series?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Cornelius UCR 700 Series, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Cornelius UCR 700 Series probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)