Manual de instrucciones Bryant 355MAV

12 de páginas 0.29 mb
Descargar

Pasar a la página of 12

Summary
  • Bryant 355MAV - page 1

    USER’S INFORMA TION MANU AL MODEL 340MA V , 350MA V , 352MA V , 355MA V CONDENSING GAS FURN A CE NO TE TO INST ALLER: This manual must be left with the equipment user . USER: Please read all instructions in the manual and retain all manuals f or future reference. W ARNING: FIRE OR EXPLOSION HAZARD F ailure to f ollow safety warnings exactly could ...

  • Bryant 355MAV - page 2

    WELCOME T O A NEW GENERA TION OF COMFOR T Congratulations! In light of rising energy costs, the Plus 90 TM , 340MA V , Plus90t™ and Plus 90i TM Multipoise, Gas-Fired, Condensing Furnaces are among the soundest in vestments today’ s homeo wner can make. Y our new furnace is truly a triumph of technology in home heating. A re volutionary design e ...

  • Bryant 355MAV - page 3

    3 FURN A CE COMPONENTS Combustion-air intake connection to ensure contaminant-free air (right or left side). Burner sight glass for viewing burner flame. Burner assembly (inside). Operates with energy- saving inshot burners and hot surface igniter for safe, dependable heating. Redundant gas valve. Safe and efficient. Features 1 gas control with 2 i ...

  • Bryant 355MAV - page 4

    4 SAFETY CONSIDERA TIONS Recognize safety information. This is the safety-alert symbol . When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury . Understand the signal words D ANGER, W ARNING, CA UTION and NO TE. DANGER , WARNING and CAUTION are used with the safety-alert symbol. D ANGE ...

  • Bryant 355MAV - page 5

    5 the fl oor . If you smell gas, STOP! Follo w “ B ” in the safety information abov e on this furnace label. If you don ’ t smell gas, go to the ne xt step. • If a suspected malfunction occurs with your gas control system, such as the burners not lighting when the y should, refer to the shutdo wn proce- dures on inside of main furnace door ...

  • Bryant 355MAV - page 6

    6 necessary adjustments to operate the blo wer at either the low- or high-heat speed. 16 17 18 NO TE: If the burners f ail to ignite after 4 attempts, the furnace control system will lock out. If lockout occurs, main burners f ail to light, or blower does not come on, shut do wn the furnace and call your dealer for service. 12 . S et your thermosta ...

  • Bryant 355MAV - page 7

    7 Installing and servicing of heating equipment can be hazardous due to gas and electrical components. Only trained and quali fi ed personnel should install, repair , or service heat- ing equipment. Untrained personnel can perform basic maintenance func- tions such as cleaning and replacing air fi lters. All other operations must be performed by ...

  • Bryant 355MAV - page 8

    8 direction arro w pointing towards blo wer . b . Electronic air cleaner (EA C) – Refer to EA C owner ’ s Manual for maintenance information. 27 28 29 30 31 5. If washable fi lter , wash fi lter (if dirty) in sink, bathtub, or outside with a garden hose. Alw ays use cold tap water . A mild liquid deter- gent may be used if necessary . Spray w ...

  • Bryant 355MAV - page 9

    9 FURNA CE AIR FIL TER T ABLE * F actor y-provided with the furnace. Filters may be fi eld modi fi ed by cutting fi lter material and support rods (3) in fi lters. Alternate sizes and additional fi l- ters may be ordered from y our dealer . † Up fl ow only . COMBUSTION AREA AND VENT SYSTEM V isually inspect the combustion area and vent syst ...

  • Bryant 355MAV - page 10

    10 transfer process. Therefore, once it has been operated, it cannot be turned of f and left off for an extended period of time when temperatures will reach 32 ° F or lo wer unless winterized. Fol- lo w these procedures to winterize your furnace: 1. Obtain propylene glycol (R V/ swimming pool antifreeze or equi valent). 2. T urn of f electrical su ...

  • Bryant 355MAV - page 11

    11 Ensure they are open and unobstructed. If problem still exists, call your dealer for service. IF FURN A CE F AILS TO OPERA TE: Follo w this checklist step by step, adv ancing to the next step only if fur- nace fails to start. • Check thermostat for proper tem- perature. Is thermostat set abov e room temperature? • Is thermostat set to HEA T? ...

  • Bryant 355MAV - page 12

    Cancels: OM05-39 OM05-42 © 2003 Bryant Heating & Cooling Systems, 7310 W . Morris St., Indpls., IN 46231 12 Printed in U.S .A. Catalog No . 5334-017 10-03 INST ALLA TION D A T A Date Installed Dealer Name Address City State Zip T elephone FURNA CE Product No . Model No . Serial No . AIR CONDITIONER OR HEA T PUMP OUTDOOR UNIT: Product No . Mode ...

Fabricante Bryant Categoría Furnace

Los documentos del dispositivo Bryant 355MAV que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Bryant
- manuales de instrucciones 355MAV
- hojas de producto Bryant
- folletos informativos
- o etiquetas energéticas Bryant 355MAV
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Bryant 355MAV.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Bryant 355MAV, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Bryant 355MAV. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Bryant 355MAV.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Bryant 355MAV, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Bryant 355MAV. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Bryant 355MAV.

El manual de instrucciones completo de Bryant debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Bryant 355MAV - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Bryant 355MAV, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Bryant 355MAV que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Bryant 355MAV - que deben facilitarnos los primeros pasos durante el uso de Bryant 355MAV
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Bryant 355MAV
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Bryant 355MAV en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Bryant 355MAV?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Bryant 355MAV, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Bryant 355MAV probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)