  • Vulcan-Hart LG500 - page 1

    INSTALLATION & OPERATIONAL MANUAL LG SERIES GAS FRYERS M O D E L S : LG300 ML-136528 LG400 ML-136622 LG500 ML-136643 For additional information on Vulcan-Hart or to locate an authorized parts and service provider in your area, visit out website at www.vulcanhart.com VULCAN-HART 3600 NORTH POINT BLVD. DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC BA ...

  • Vulcan-Hart LG500 - page 2

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT T ...

  • Vulcan-Hart LG500 - page 3

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY………………………………………. 2 INTRODUCTION…………………………………………………………… 4 GENERAL…………………………………………………………… 4 ORDERING PARTS…………… ...

  • Vulcan-Hart LG500 - page 4

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance. Before installing the fryer, thoroughly read th is manual and carefully fo llow all instruction. This ...

  • Vulcan-Hart LG500 - page 5

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -5- INSTALLATION Before installing the fryer, veri fy that the type of gas (natural or propane) agrees with the specifications on the fryer data pl ate, which is located on the inside of the door panel. Make sure the fryer is configur ed for the proper elevation. Record your fryer model, ...

  • Vulcan-Hart LG500 - page 6

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -6- CODES AND STANDARDS The fryer must be insta lled in accordance with: In the United States:  State and local codes, or in the absence of local codes, with:  National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may be obtained from The American Gas Association Ac ...

  • Vulcan-Hart LG500 - page 7

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -7-  Locate the fryer under a hood with adequate connection to an exhaust duct. The hood must extend 6” ( 15 cm) beyond fryer on both sides.  Clearance above the fryer should be adequate for combustion byproducts to be removed efficiently.  An 18” (46 cm) minimum clearance s ...

  • Vulcan-Hart LG500 - page 8

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -8- Make sure the pipes are clean and free of obstructions, dirt, and piping compound. A battery requires one or two connections of appropriate size for the gas requirement. Prior to lighting, check all joints in the g as supply line for leaks. Use soap and water solution. Do not use an ...

  • Vulcan-Hart LG500 - page 9

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -9-  When installing a quick disconnect you must also install a means for limiting the movement of the fryer. This device wil l prevent the gas line or quick disconnect from being strained. The rest raining device should be attached to the cutout on the back panel. See illustration fo ...

  • Vulcan-Hart LG500 - page 10

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -10- OPERATION Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank. OVER-TEMPERATURE SHUTDOWN If the shortening becomes over ...

  • Vulcan-Hart LG500 - page 11

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -11- FILLING TANK WITH SHORTENING Solid shortening should NOT be used with LG300 fryers. Melting solid shortening will damage the tank and void your warranty.  Close the drain valve.  Fill the fryer tank wit h liquid shortening.  Shortening level should be between the min and ma ...

  • Vulcan-Hart LG500 - page 12

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -12- LIGHTING THE PILOT 1. Open the door. 2. Turn the thermostat OFF (s ee figure below, view A). The thermostat is located behind the door. 3. Push the gas control valve knob and turn to OFF. Wait 5 minutes for unburned gas to vent. 4. Push and turn gas control valve knob to the “L” ...

  • Vulcan-Hart LG500 - page 13

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -13- TURNING ON THE FRYER  Set the temperature knob to desired temperature.  After the set temperature has been reac hed, the thermostat shuts off the gas flow to burners.  The pilot remains lit. The burners wil l cycle on and off, maintaining the set temperature. TURNING OFF TH ...

  • Vulcan-Hart LG500 - page 14

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -14- Fry Basket Guidelines  Do not overfill baskets. (See table for recommended basket capacities below) Carefully lower basket into oil.  When frying doughnuts and fritters, turn product only once during frying.  When cooking French fries or onion rings, shake the basket severa ...

  • Vulcan-Hart LG500 - page 15

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -15- DRAINING THE TANK 1. Turn the thermostat to OFF. 2. To keep the pilot lit, turn the gas valve to PILOT. 3. Direct the drain spout into the container t hat you want to drain the shortening into. 4. Open the drain valve. The oil will drain into the container. When the container is ful ...

  • Vulcan-Hart LG500 - page 16

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -16- CLEANING Hot oil and hot parts can cause burns. Use care when operating, cleani ng, and servicing the fryer. Daily Clean your fryer regularly wit h the tank brush along with a damp cloth, and polish with a soft dry cloth. If regular cleani ng is neglected, grease will be burned on a ...

  • Vulcan-Hart LG500 - page 17

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -17-  Remove discolorations by washing with any detergent or soap and water.  Use a self-soaping, non-metallic scouring pad for particularly stubborn discolorations.  Always rub with the grain of the stainless steel.  Do not use a metallic scoring pad or harsh cleaners. BOIL ...

  • Vulcan-Hart LG500 - page 18

    LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -18- MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, clean ing, and servicing the fryer. Spilling hot fryer com pound can cause severe burns. Do not move fryer without draining all frying compound from the tank. FLUE VENT INSPECTION When the fryer is cool, ins ...

Fabricante Vulcan-Hart Categoría Fryer

Los documentos del dispositivo Vulcan-Hart LG500 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Vulcan-Hart
- manuales de instrucciones LG500
- hojas de producto Vulcan-Hart
- folletos informativos
- o etiquetas energéticas Vulcan-Hart LG500
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Vulcan-Hart LG500.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Vulcan-Hart LG500, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Vulcan-Hart LG500. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Vulcan-Hart LG500.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Vulcan-Hart LG500, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Vulcan-Hart LG500. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Vulcan-Hart LG500.

El manual de instrucciones completo de Vulcan-Hart debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Vulcan-Hart LG500 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Vulcan-Hart LG500, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Vulcan-Hart LG500 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Vulcan-Hart LG500 - que deben facilitarnos los primeros pasos durante el uso de Vulcan-Hart LG500
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Vulcan-Hart LG500
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Vulcan-Hart LG500 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Vulcan-Hart LG500?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Vulcan-Hart LG500, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Vulcan-Hart LG500 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)