Manual de instrucciones Liebert PSP

32 de páginas 1.39 mb
Descargar

Pasar a la página of 32

Summary
  • Liebert PSP - page 1

    P OWER A VAILABILITY P OW E R S UR E ™ PSP U SER M ANUAL 350-650 V A 120V ...

  • Liebert PSP - page 2

    ...

  • Liebert PSP - page 3

    i T ABLE OF CONTENTS I MPORT ANT S AFETY I NSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . 1 I NTRODUCTION & S YSTEM D ESCRIPTION . . . . . . . . . . . . . . . . . 4 Front View of UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Rear View of UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Liebert PSP - page 4

    ii M AINTENANC E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Cleaning the UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Maintaining Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Liebert PSP - page 5

    1 I MPORT ANT S AFETY I NSTRUCTIONS SA VE THESE INSTRUCTIONS This manual contains important safety instru ctions that should be fol- lowed during the installa tion and maintenance of the Uninterruptible Power System (UPS) and its batteries. Please read this manual thor- oughly before attempting to install or operate this UPS. Read all safety, insta ...

  • Liebert PSP - page 6

    2 CONDITIONS OF USE: The input receptacle mu st be within 6 feet (1.8 meters) of the UPS. Your UPS provides conditioned powe r to connected equipment. Maxi- mum load must not exceed that shown on UPS ra ting label. If uncer- tain, consult your local dealer, Lieb ert representative or the Liebert Worldwide Support Group. Placing magnetic storage med ...

  • Liebert PSP - page 7

    3 ! CAUTION BATTERY HANDLING PRECAUTIONS Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and required precautions. Keep unauthorized p ersonnel away from the batteries. A battery can present a risk of electrical shock and high short-circuit current. The foll owing precautions should be observed when ...

  • Liebert PSP - page 8

    4 I NTRODUCTION & S YSTEM D ESCRIPTION Congratulations on your choice of the Liebert PowerSure™ PSP Uninterruptible Power System (UPS) . It provides filtered AC power to sensitive electronic equipm ent and other critical loads. The PowerSure PSP is an off-line UPS designed for desktop applications. It provides perfect one-to-one power protect ...

  • Liebert PSP - page 9

    5 Front View of UPS Power ON/OFF/ Alarm Silence* Battery Indicator* (Green / Amber) Fault Indicator* (Red / Green) Utility Indicator* (Green) * For det ails, see Controls and In dicators section ...

  • Liebert PSP - page 10

    6 Rear V iew of UPS 6-ft . (1.8 m) power cord DB-9 port*** Input circuit protector USB port*** DIP switches** Orange output receptacles (4)* Battery backup + surge protection Black output receptacles (2)* Surge prote ction only Site Wiring Fault Indicator (Red)** Dat a Line Protection Connectors (2)*** Phone / Fax /DSL/ Internet/ Modem devices Batt ...

  • Liebert PSP - page 11

    7 M AJOR C OMPONENT S T ransient V oltage Surge Suppression (TVSS) & EMI / RFI Filters These UPS components provide surg e protection and filter electro- magnetic interference (EMI) and ra dio frequency interference (RFI). They minimize surges or interferen ce present in the u tility line and keep the sensitive equipment protected. T ransfer Sw ...

  • Liebert PSP - page 12

    8 W HAT ’ S I NCLUDED The PowerSure PSP is shipped wi th the following components: • Quick-Start guide • PowerSure family user manual o n CD • Warranty card • MultiLink™ software CD • MultiLink serial cabl e (M3LS9P9S), 10 ft. (3 m) • RJ-11 cord, 7 ft. (2.1 m) • USB cable, 6 ft. (1.8 m) MultiLink serial ca ble (M3LS9P9S) 10 f t. ( ...

  • Liebert PSP - page 13

    9 I NST A LLATION 1. Visually inspect the UPS for frei ght damage. Report damage to the carrier and your local dealer, Lieb ert representative or the Liebert Worldwide Support Group. 2. Decide where to place the P owerSure PSP. Install the UPS indoors in a controlled environment, where it cannot be acci dentally turne d off. Place it in an area of ...

  • Liebert PSP - page 14

    10 5. Connect Phone/Fax/DSL/Internet /Modem devices to data line connectors. 6. Press and release the ON / OFF /Alarm Silence button to turn on the UPS. The UPS will beep and the Utility Indicator will illuminate (green). 7. Turn on connected equipment. 8. Communication options (see Communications section for deta ils): Option 1—Serial Communicat ...

  • Liebert PSP - page 15

    11 C ONTROLS AND I NDICATORS ON / OFF / Alarm Silence Button This button controls output power to the connected load and has three functions: •O N •O F F • Alarm Silence ON When the UPS is off, pressing and releasing the mai n ON / OFF button will star t the UPS, and an audible a larm sounds briefly. The UPS is capable of starting on battery ...

  • Liebert PSP - page 16

    12 St atus Indicators: Faul t, Utility , Battery There are three (3) status indicators on the front of the UPS (Utility, Battery and Fault), as shown in the diag ram below. Each indicator illuminates to sp ecify the status of th e UPS (see Troubleshooting section for detai ls). Utility Indicator (Green) The Utility Indicator illumi nates green when ...

  • Liebert PSP - page 17

    13 Site Wiring Fault Indicator (Red) The Site Wiring Fault Indicator on the rear panel, as shown below, illuminates red when the UPS detects a line-neutral reversal or a poor neutral-ground. (Refer to Troubleshootin g Chart if this indicator is illuminated.) T ransfer V oltage Sele ctors (DIP Switches) The two-position DIP switch contro l on the re ...

  • Liebert PSP - page 18

    14 M ODES OF O PERATION Normal Mode During Normal mode operation, the PowerSure PSP supplies condi- tioned, computer-grade power to the connected equipment: utility power passes through the EMI / RFI filters and TVSS circuitry and then through the Tran sfer Switch to the connected equipment. When the UPS is in Normal mode, the Utilit y Indicator il ...

  • Liebert PSP - page 19

    15 Battery Mode The UPS switches to Battery mode in the event of an ex treme voltage/ frequency condi tion or complete util ity failure. The battery system supplies power through the Inverter to generate power for the con- nected equipment. When the UPS is in Battery mode, the Battery In dicator il luminates green and an alarm sounds every 10 secon ...

  • Liebert PSP - page 20

    16 C OMMUNICATIONS DB-9 Connector The UPS has a DB-9 (9 pin female) connector on the rear to all ow UPS status communications with a computer system running MultiLink™ software. The DB-9 is capable of su pplying serial communi cation, on battery and lo w battery sig nals. Mu ltiLink, Liebert’s UPS monitoring and shutdown software, is shipped wi ...

  • Liebert PSP - page 21

    17 Remote Shut down Via the DB-9 Connector The PowerSure PSP can be shut down remotely by shorting Pins 5 and 6 or via Pins 4 and 5 of the DB-9 connector. Shut down Via Pins 5 & 6 When Pin 6 is shorted to Pin 5, th e UPS output is shut off regardless of what mode the UPS is operating in. The UPS cannot be started as long as the pins are shorted ...

  • Liebert PSP - page 22

    18 M AINTENANCE The PowerSure PSP UPS requires ve ry little maintenance. Follow these practices to prevent probl ems. Cleaning the UPS The following will help ensure trouble-free operation for years: • Vacuum dust from the ventil ation intake occasionally. • Wipe the cover periodical ly with a dry cloth. Maint aining Batteries The batteries are ...

  • Liebert PSP - page 23

    19 Battery Replacement Proc edure Replacement requires removing the battery cover plate on the bottom of the UPS. No tools are needed. To replace the batteries: 1. Remove the battery cover plate on the bottom of the UPS. 2. Pull the white tab towards you to remove the battery from the UPS. Pivot battery 90 degrees clockwi se as shown below. 3. Disc ...

  • Liebert PSP - page 24

    20 T ROUBLESHOOTING The informatio n below indicates various symptoms a user may encounter in the event the PowerSur e PSP experiences a problem. Use this information to determine wh et her external factors caused the problem. See Troubleshooting Chart for suggested remedy. Guide to St atus Indicators 1. The Fault indicator illu minates, indicating ...

  • Liebert PSP - page 25

    21 T roubleshooting Chart If the UPS fails to operate properly , turn off the uni t and repeat the steps in the Installation section of this manua l. If the problem per- sists, refer to the chart below: Problem Cause Solution UPS will not st art Overload/Short Circuit Check the circui t protector on the rear of the UPS. If it is tripped, rese t it ...

  • Liebert PSP - page 26

    22 S PECIFICATIONS Model Number PSP350MT -1 20 PSP500MT -120 PSP650MT -120 Power Rating V A/W 350 V A / 210 W 500 V A / 300 W 650 V A / 390 W DIMENSIONS: in. (mm ) Unit W x D x H 3.7 x 9.5 x 8 (95 x 240 x 205) 3.7 x 9.5 x 8 (95 x 240 x 205) 3.7 x 9. 5 x 8 (95 x 240 x 205) Shipping W x D x H 6.7 x 13.1 x 1 1.5 (171 x 332 x 293) 6.7 x 13.1 x 1 1.5 (1 ...

  • Liebert PSP - page 27

    23 Battery Run Times Product W arranty Registration To register for warranty protection: •V i s i t t h e Quick Link s section of our Web site at: http://www .liebert.com • Click on Product Warranty Registration and fill in the form. If you have an y questions, please contact us a t: US: 800-222 -5877 Outside the US: 614-841-6755 upstech@lieber ...

  • Liebert PSP - page 28

    24 ...

  • Liebert PSP - page 29

    PowerSure PSP Mounting T emplate 1. Remove this template from the user manual. 2. Line template up to wa ll at desired location. 3. Drill holes where cross hairs are located on templat e. 4. Remove template and mount scre ws, us ing (3) #8 or M4 screws. (Distance f rom head of screw to wall should be 0.25" or 6.4mm. ) 5. Mount PowerSure PSP to ...

  • Liebert PSP - page 30

    ...

  • Liebert PSP - page 31

    ...

  • Liebert PSP - page 32

    T echnica l Support / Service Web S ite www .liebert.com Monitoring 800-222-5877 monitoring@liebert.com Outside the US: 614-841-6755 Single-Phase UPS 800-222-5877 upstech@liebert.c om Outside the US: 614-841-6755 Three-Phase UPS 800-543-2378 powertech@liebert.com Environment al Systems 800-543-2778 Outside the United S tat es 614-888-0246 Locations ...

Fabricante Liebert Categoría Power Supply

Los documentos del dispositivo Liebert PSP que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Liebert
- manuales de instrucciones PSP
- hojas de producto Liebert
- folletos informativos
- o etiquetas energéticas Liebert PSP
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Liebert PSP.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Liebert PSP, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Liebert PSP. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Liebert PSP.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Liebert PSP, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Liebert PSP. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Liebert PSP.

El manual de instrucciones completo de Liebert debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Liebert PSP - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Liebert PSP, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Liebert PSP que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Liebert PSP - que deben facilitarnos los primeros pasos durante el uso de Liebert PSP
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Liebert PSP
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Liebert PSP en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Liebert PSP?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Liebert PSP, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Liebert PSP probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)