Manual de instrucciones Sanyo KS1872

25 de páginas 1.23 mb
Descargar

Pasar a la página of 25

Summary
  • Sanyo KS1872 - page 1

    85264189988000 © SANY O 2006 In Canada SANY O FISHER COMP ANY SANY O Canada Inc. A DIVISION OF SANY O NOR TH AMERICA CORPORA TION 300 Applew ood Crescent, Concord 21605 Plummer Street Ontario, L4K 5C7, Canada Chats wor th, CA 91311 U .S .A. W Contents P age IMPORT ANT! Please Read Before Starting .................................. 2 1. GENERAL ... ...

  • Sanyo KS1872 - page 2

    2 IMPOR T ANT! Please Read Bef ore Star ting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an impor tant par t of your job to install or service the system so it operates saf ely and efficiently . For safe installation and tr ouble-free operation, y ou must: G Carefully read this ...

  • Sanyo KS1872 - page 3

    3 1. General This booklet briefly outlines where and how to install the air conditioning system. Please read ov er the entire set of instructions for the indoor and outdoor units and mak e sure all accessor y par ts listed are with the system before beginning. 1-1. T ools Required for Installation (not supplied) 1. Standard screwdriver 2. Phillips ...

  • Sanyo KS1872 - page 4

    4 1-5. Additional Materials Required f or Installation 1. Refrigeration (ar mored) tape 2. Insulated staples or clamps f or connecting wire (See local codes) 3. Putty 4. Refrigeration lubricant 5. Clamps or saddles to secure refrigerant tubing 2. Installation Site Selection 2-1. Indoor Unit A V OID: G direct sunlight. G nearby heat sources that ma ...

  • Sanyo KS1872 - page 5

    5 2-2. Outdoor Unit A V OID: G heat sources, e xhaust fans , etc. (Fig. 4) G damp , humid or unev en locations. DO: G choose a place as cool as possible . G choose a place that is well v entilated. G allow enough room around the unit f or air intake/ e xhaust and possible maintenance . (Fig. 5a or 5b) G provide a solid base (le vel concrete pad, co ...

  • Sanyo KS1872 - page 6

    6 2-3. Baffle Plate for the Outdoor Unit (CLxx models only) It is recommended to use baffle plates f or models CL1872 and CL2472. The baffle plates are not normally required f or the other models. When the outdoor unit is installed in a position e xposed to strong wind (like seasonal winds with lo w air tempera- ture in winter), baffle plates must ...

  • Sanyo KS1872 - page 7

    7 Set screw only for transportation Fig. 6 Rear panel marks Fig. 7 Left tubing Right tubing Downward tubing Right-rear tubing (recommended) Left-rear tubing Fig. 8 3. How to Install the Indoor Unit 3-1. Remove the Rear P anel from the Unit (1) Remo ve and discard the set scre w on the rear panel. (Fig. 6) (2) Press the 2 L L marks on the frame cov ...

  • Sanyo KS1872 - page 8

    8 Indoor side Outdoor side Hole should be made at a slight downw ard slant to the outdoor side. NOTE Fig. 10 Plastic cover INSIDE OUTSIDE W all Slight angle PVC pipe (Locally purchased) Fig. 12 PVC pipe (Locally purchased) Cut at sli g ht an g le Fig. 11 (4) Using a sabre sa w , key hole sa w or hole-cutting dr ill attachment, cut a hole in the wal ...

  • Sanyo KS1872 - page 9

    9 3-4. Remove the Grille to Install the Indoor Unit Basically , these models can be installed and wired with- out removing the grille. If access to an y inter nal par t is needed, f ollow the steps as giv en below . How to remo ve the grille (1) Grasp both ends of the air intak e grille, and remov e it by opening to wards the front and pulling to w ...

  • Sanyo KS1872 - page 10

    10 3-5. Shape the Indoor Side T ubing (1) Arrangement of tubing b y direction a) Right or left tubing Cut out the cor ner of the right/left frame with a hacksa w or the like. (Figs . 20 and 21) b) Right-rear or left-rear tubing In this case, the corner of the frame need not be cut. (2) T o mount the indoor unit on the rear panel: Hang the 2 mountin ...

  • Sanyo KS1872 - page 11

    11 (A)+(B) (A) P ower Suppl y Wiring Length (ft) (C) Control Fuse or Circuit AW G (B) Po wer Line Length (ft) Line Length (ft) Model (#14) (#12) (#14) Breaker Capacity C1872, C2472, CL1872, CL2472 131 (Max.) 230 (Max.) 65 (Max.) 20A 3-7. Recommended Wire Length and Diameter Regulations on wiring diameter differ from locality to locality . For field ...

  • Sanyo KS1872 - page 12

    12 3-8. Wiring Instructions for Inter -unit Connections (1) Insert the inter-unit wir ing (according to local codes) into the through-the-wall PVC pipe . Run the wiring tow ard the indoor side allowing appro x. 10" (25 cm) to e xtend from the wall f ace. (Fig. 24) (2) Gr asp both ends of the air intake g rille, and remov e it by opening to war ...

  • Sanyo KS1872 - page 13

    13 When connecting each power wire to the corresponding terminal, follow the instructions “How to connect wiring to the ter minal” and f asten the wire securely tight with the fixing screw of the terminal plate. How to connect wiring to the terminal a) For Indoor Unit (1) Cut the wire end with a cutting pliers, then strip the insulation to e xp ...

  • Sanyo KS1872 - page 14

    14 3-9. Mounting (1) T o install the indoor unit, mount the indoor unit onto the 2 tabs on the upper par t of the rear plate. (2) Hold down the air discharge outlet and press the lower part of the indoor unit until it clicks to securely f asten to the 2 tabs on the lower part of the rear plate. (Fig. 33) F or tubing, choose either the right or left ...

  • Sanyo KS1872 - page 15

    15 Hole in wall Bent part Narrow tube Wide tube Rear panel Fig. 38 Drain cap Drain hose Fig. 39 I Left-side tubing (1) Lead the tubing and drain hose through the wall, allowing sufficient length f or connection. Then bend the tubing using a tube bender to make the attach- ment. (Fig. 38) (2) Switch the drain hose and drain cap . Switching drain hos ...

  • Sanyo KS1872 - page 16

    16 T o unmount indoor unit Press the 2 L L mar ks on the low er par t of the indoor unit and unlatch the tabs. Then lift the indoor unit and unmount. (Fig. 42) 3-10. Drain Hose a) The drain hose should be slanted downw ard to the outdoors. (Fig. 43) b) Ne ver f or m a trap in the course of the hose. c) If the drain hose will run in the room, insula ...

  • Sanyo KS1872 - page 17

    17 4. How to Install the Outdoor Unit First ref er to Section 2. Installation Site Selection. 4-1. Wiring Instructions for the Outdoor Unit Regulations on wire size diff er from locality to locality . F or field wiring requirements, please ref er to your local elec- trical codes. Make sure that the installation fully complies with all local and nat ...

  • Sanyo KS1872 - page 18

    18 5. Refrigerant T ubing 5-1. Use of the Flaring Method Many of the con v entional split system air conditioners emplo y the flaring method to connect refr igerant tubes which run between indoor and outdoor units. In this method, the copper tubes are flared at each end and connected with flare nuts. 5-2. Flaring Procedure with a Flare T ool (1) Cu ...

  • Sanyo KS1872 - page 19

    19 5-4. Connecting T ubing between Indoor and Outdoor Units a) Tightly connect the indoor side refrigerant tubing exten- ded from the wall with the outdoor side tubing. (Fig. 52) b) T o f asten the flare nuts, apply specified torque as: T able 6 5-5. Insulation of Refrigerant T ubing T o pre v ent heat loss and wet floors due to dripping of con- de ...

  • Sanyo KS1872 - page 20

    20 6. Air Purging Air and moisture remaining in the refrigerant system hav e undesirable eff ects as indicated below . Theref ore, they m ust be purged completely . G pressure in the system rises G operating current rises G cooling (or heating) efficiency drops G moisture in the air ma y freeze and b lock capillary tubing G water ma y lead to corro ...

  • Sanyo KS1872 - page 21

    21 (5) With the v acuum pump still r unning, close the “Lo” knob of the manif old valv e. Then stop the v acuum pump . (6) With the accessory hex wrench, turn the valv e stem on the narrow tube service valv e counter-clockwise by 90 deg rees (1/4 tur n) f or 10 seconds, and then turn the stem clockwise to close it again. (Fig. 58) (7 ) Leak tes ...

  • Sanyo KS1872 - page 22

    22 How to T est Run the Air Conditioner After turning on power to the air conditioner , use the remote controller and f ollow the steps belo w to conduct the test run. (1) Set the remote controller in T est Run mode. (Fig. 59a) a) Press and hold the ION button. b) Then press and hold the 1HR TIMER button. c) At the same time , press the A CL (reset ...

  • Sanyo KS1872 - page 23

    23 I Pump Down Pump down means collecting all refrigerant gas in the system back into the outdoor unit without losing an y of the gas. Pump do wn is used when the unit is to be mov ed or before servicing the refr igerant circuit. Pump Down Pr ocedure Be sure to carry out pump down with the unit in cooling mode. (1) Connect the Lo side charging hose ...

  • Sanyo KS1872 - page 24

    24 7 . Remote Control Unit Installation P osition The remote control unit can be operated from either a non-fix ed position or a wall-mounted position. T o ensure that the air conditioner operates correctly , do not install the remote control unit in the f ollowing places: G In direct sunlight G Behind a cur tain or other place where it is cov ered ...

  • Sanyo KS1872 - page 25

    25 8. Address Switch 8-1. Address Setting of the Remote Contr ol Unit The address can be set in order to pre vent interf erence between remote controllers when two San yo indoor units are installed near each other . The address is nor mally set to “A. ” T o set a different address, it is necessary to change the address on the second remote cont ...

Fabricante Sanyo Categoría Air Conditioner

Los documentos del dispositivo Sanyo KS1872 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Sanyo
- manuales de instrucciones KS1872
- hojas de producto Sanyo
- folletos informativos
- o etiquetas energéticas Sanyo KS1872
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Sanyo KS1872.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Sanyo KS1872, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Sanyo KS1872. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Sanyo KS1872.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Sanyo KS1872, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Sanyo KS1872. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Sanyo KS1872.

El manual de instrucciones completo de Sanyo debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Sanyo KS1872 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Sanyo KS1872, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Sanyo KS1872 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Sanyo KS1872 - que deben facilitarnos los primeros pasos durante el uso de Sanyo KS1872
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Sanyo KS1872
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Sanyo KS1872 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Sanyo KS1872?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Sanyo KS1872, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Sanyo KS1872 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)