    1 W415-0619 / B / 03.03.08 INST ALLA TION AND OPERA TION INSTRUC TIONS W olf Steel Ltd., 24 Napoleon Rd ., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 ww w .napoleonreplaces .com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACE. GT8N NA TURAL GA ...

  • Napoleon Fireplaces GT8N - page 2

    2 W415-0619 / B / 03.03.08 PG 2-5 INTRODUCTION W arranty General Instructions General Information Care of Glass and Plated Parts Dimensions 5-10 VENTING V enting Lengths and Air T erminal Locations Vent Installations T ypical V ent Installations - Horizontal T ermination T ypical V ent Installations - V ertical T ermination Minimum Air T erminal Lo ...

  • Napoleon Fireplaces GT8N - page 3

    3 W415-0619 / B / 03.03.08 ® ® ® ® ® ® ® ® ® ® ® ®® ® ® ® ® e following ma te rials and workmanship in your new NAPO LEON® gas firepla ce are waanted agains t defects for as long as you own the fireplace.  is covers: combus tion chamber , hea t changer , s tainle s t eel burner , gold pla ted par t s agains t tarn ...

  • Napoleon Fireplaces GT8N - page 4

    4 W415-0619 / B / 03.03.08 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to region and it is important to know the speci fi cs that apply to your area, for example: in Massachusetts State: • The fi replace damper must be removed or welded in th ...

  • Napoleon Fireplaces GT8N - page 5

    5 W415-0619 / B / 03.03.08 3 / 4 43 GAS LINE ACCESS ELECTRICAL ACCESS FIGURES 1a-c The glass is 3/16” ceramic glass, available from your Napoleon® / Wolf Steel Ltd. dealer . Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace glass cleaner . Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! Do not ...

  • Napoleon Fireplaces GT8N - page 6

    6 W415-0619 / B / 03.03.08 For safe and proper operation of the fi replace follow the venting instruction exactly . Deviation from the minimum or the maximum vertical vent length can create dif fi culty in burner start-up and/or carboning. Under extreme vent con fi gurations, allow several minutes (5-15) for the fl ame to stabilize after igniti ...

  • Napoleon Fireplaces GT8N - page 7

    7 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - HORIZONT AL TERMINA TION MIN MAX FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) N/A 1 Rise per foot (recommended) 1/4” N/A Rise per foot (allowable) 0” N/A Horizontal run (If vent run does not include vertical rise) 4” 24” 2a Horizontal ru ...

  • Napoleon Fireplaces GT8N - page 8

    8 W415-0619 / B / 03.03.08 TYPICAL VENT INST ALLA TIONS - VERTICAL TERMINA TION 24” MIN. MINIMUM VERITICAL 4” MIN. FIGURE 3a 24” MIN. MINIMUM VERITICAL MAXIMUM HORIZONT AL 5 FT MAX. 15 FT MAX. 4” MIN. MAXIMUM VERTICAL 19 1/2 FT MAX. 4” MIN. MIN MAX FIGURE Allowable 3” vent connections (excluding fi replace and air terminal connections) ...

  • Napoleon Fireplaces GT8N - page 9

    9 W415-0619 / B / 03.03.08 O O B B G A F C H H L K J M MINIMUM AIR TERNMINAL L OCA TION CLEARANCES N D E O FIGURE 4 ...

  • Napoleon Fireplaces GT8N - page 10

    10 W415-0619 / B / 03.03.08 INST ALLA TION / FRAMING WALL AND CEILING PRO TECTION This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum square opening of 8” wide x 8” high. 1. Apply a bead of caulking all around and place the fi restop ...

  • Napoleon Fireplaces GT8N - page 11

    11 W415-0619 / B / 03.03.08 1. Stretch the 3” fl exible vent pipe to the required length taking into account the additional length needed for the fi nished wall surface. Apply a heavy bead of the high temperature sealant W573-0007 (not supplied). Slip the fl exible vent pipe a minimum of 2” over the inner sleeve of the air terminal and secur ...

  • Napoleon Fireplaces GT8N - page 12

    12 W415-0619 / B / 03.03.08 HIGH TEMPERA TURE SEALANT 1 1 / 2 ” OVERLAP SCREWS 1. Install the 3” fl exible vent pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using Mill Pac sealant (W573-0007 not supplied). 2. Install the 5” fl exible vent pipe to the fi replace. Attach and seal the joints ...

  • Napoleon Fireplaces GT8N - page 13

    13 W415-0619 / B / 03.03.08 Do NOT use the fireplace if any part has been under water . Call a qualified service technician IMMEDIA TEL Y to have the fi replace inspected for damage to the electrical circuit. IT IS NECESSAR Y T O HARD WIRE THIS FIREPLACE. Permanently framing the fi replace with an enclosure, requires the fireplace junction box to ...

  • Napoleon Fireplaces GT8N - page 14

    14 W415-0619 / B / 03.03.08 FRAMING FIGURES 21a,b&c NAILING T AB INST ALLA TION Attach the 4 nailing tabs supplied to the sides of the outer shell as illustrated using the 8 self-tapping screws included in the manual baggie. FIGURE 20 The has been designed to be installed mid-way up a wall. When installing this unit close to the fi nished fl ...

  • Napoleon Fireplaces GT8N - page 15

    15 W415-0619 / B / 03.03.08 2” MIN.* 12” MIN. TO COMBUSTIBLES (to ceiling or mantle) 1 1 / 2 ” MIN. * Any protruding finishing material installed in this space (ie. baseboards) must leave 2” of unobstructed clearance to allow for full rotation of the control door . COMBUSTIBLE NON-COMBUSTIBLE 1” 1” 0” IF NON-COMBUSTIBL E FINISHING IS ...

  • Napoleon Fireplaces GT8N - page 16

    16 W415-0619 / B / 03.03.08 FIGURE 28 RECEIVING SLOTS DOOR STOP CHAIN FRAME/FRONT INST ALLA TION 1. Align the two holes in the upper portion of the hinge on the control door to those in the bottom trim bracket, secure using two of the #8 x 1/2” hex head screws supplied. Figure 26 2. Install the top trim bracket to the fi rebox using the three #9 ...

  • Napoleon Fireplaces GT8N - page 17

    17 W415-0619 / B / 03.03.08 LK8 LIGHT INST ALLA TION (OPTIONAL) 1 . T urn off the electrical and gas supply to the fi replace. 2 . Remove the frame from the unit by removing the 2 black securing screws from the top, and the 2 silver hex head securing screws from the bottom. 3 . Lay the frame down on its front, being careful not to scratch the fi ...

  • Napoleon Fireplaces GT8N - page 18

    18 W415-0619 / B / 03.03.08 A. This fi replace is equipped with an ignition device which automatically lights the burner . Do not try to light by hand. B. Before operating, smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Do not use this fi replace if an ...

  • Napoleon Fireplaces GT8N - page 19

    19 W415-0619 / B / 03.03.08 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame color to be established. NOTE: It ...

  • Napoleon Fireplaces GT8N - page 20

    20 W415-0619 / B / 03.03.08 # P ART NO. DESCRIPTION 1 W225-0216 DOOR FRAME 2* W562-0008 DOOR GASKET 3* W010-1736 DOOR LA TCH ASSEMBL Y 4 W010-1743 GLASS C / W GASKET 5* W300-0088 GLASS 6 W100-0104 BURNER 7 W357-0006 IGNITOR 8 W190-0026 CONTROL, MODULE 9* W750-0183 WIRE HARNESS 10* W750-0184 IGNITION CABLE 1 1 W200-0234 IGNITOR COVER 12 W200-0233 BU ...

  • Napoleon Fireplaces GT8N - page 21

    21 W415-0619 / B / 03.03.08 TR OUBLE SHOO TING GUIDE BEFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR OPEN . SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, burner ignites, electrode continues to spark for complete 7 seconds, burner shuts down. Hot and neutral wires are re ...

  • Napoleon Fireplaces GT8N - page 22

    22 W415-0619 / B / 03.03.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...

Fabricante Napoleon Fireplaces Categoría Indoor Fireplace

Los documentos del dispositivo Napoleon Fireplaces GT8N que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Napoleon Fireplaces
- manuales de instrucciones GT8N
- hojas de producto Napoleon Fireplaces
- folletos informativos
- o etiquetas energéticas Napoleon Fireplaces GT8N
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Napoleon Fireplaces GT8N.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Napoleon Fireplaces GT8N, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Napoleon Fireplaces GT8N. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Napoleon Fireplaces GT8N.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Napoleon Fireplaces GT8N, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Napoleon Fireplaces GT8N. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Napoleon Fireplaces GT8N.

El manual de instrucciones completo de Napoleon Fireplaces debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Napoleon Fireplaces GT8N - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Napoleon Fireplaces GT8N, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Napoleon Fireplaces GT8N que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Napoleon Fireplaces GT8N - que deben facilitarnos los primeros pasos durante el uso de Napoleon Fireplaces GT8N
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Napoleon Fireplaces GT8N
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Napoleon Fireplaces GT8N en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Napoleon Fireplaces GT8N?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Napoleon Fireplaces GT8N, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Napoleon Fireplaces GT8N probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)