    990-1587, 11/2003 User Manual English APC Smart APC Smart APC Smart APC Smart- - - -UP S UPS UPS UPS ® ® ® ® 500 500 500 500 VA VA VA VA 100 Vac 100 Vac 100 Vac 100 Vac 750 750 750 750 VA VA VA VA 100/120/230 Vac 100/120/230 Vac 100/120/230 Vac 100/120/230 Vac Tower Tower Tower Tower Uninterruptible Power Supply Uninterruptible Power Supply Uni ...

  • APC 990-1587 - page 2

    ...

  • APC 990-1587 - page 3

    1 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent blackou ts, brownouts, sags, and surges from reaching y our equipment. The uninterruptible power supply (UPS) filters sm all util- ity line fluct uations and isolates yo ur equipment from large disturbances by i nternally disconnecting from the utility line. The UPS pr ...

  • APC 990-1587 - page 4

    2 Connect Equipment and Power to the UPS 1. Connect equipment to the UPS. Note: A laser printer draws signific antly more power than other types of equipment and may overload the UPS. 2. Add accessories to the Sm art-Slot (optional). 3. Connect gr ound leads to the TVSS screw (optional). To make t he connection, loosen t he screw and connect the su ...

  • APC 990-1587 - page 5

    3 2: O PERA TION Front Display Panel I NDICATOR D ESCRIPTION Online The UPS is supplying utility power to the connected equ ipment. AVR Trim The UPS is compensating for a h igh utility voltage. AVR Boost The UPS is compensating for a low utility voltage. On Battery The UPS is supplying battery power to the connected equipment. Overload The connecte ...

  • APC 990-1587 - page 6

    4 F EATURE F UNCTION Self-Test Automatic: The UPS perform s a self-test automatically when turned on, and every two weeks ther eafter (by default). During the self-test, the UPS briefly operates the conn ected equipment on battery. Manual: Press and hold the button for a few seconds to initiate the self- test. Cold Start 120V and 230V models only : ...

  • APC 990-1587 - page 7

    5 3: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE A DJUSTED THROUGH P OWER C HUTE SOFTWARE OR OPTIONAL S MA RT S LOT ACCESSORY CARDS . F UNCTION F ACT OR Y D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automatic Self- Test Every 14 days (336 hours) Every 7 d ays (168 hours), On Startup Only, No Self-Test Set the interval at which the UPS wil ...

  • APC 990-1587 - page 8

    6 N OTE : S ETTINGS ARE A DJUSTED THROUGH P OWER C HUTE SOFTWARE OR OPTIONAL S MA RT S LOT ACCESSORY CARDS . F UNCTION F ACT OR Y D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION High Transfer Point 100V model: 108 Vac 120V model: 127 Vac 230V model: 253 Vac 100V model: 108, 110, 112, 114 Vac 120V model: 127, 130, 133, 136 Vac 230V model: 253, 257, ...

  • APC 990-1587 - page 9

    7 4: S TOR AG E , M AINTENANCE , AND S HIPPING Storage Store the UPS covered in a cool, dr y location, with the battery fully charged. At -15 to +30 ° C (+5 to +86 ° F), charge the UPS battery ever y six months. At +30 to +45 ° C (+86 to +113 ° F), charge the UPS battery every three months. Battery Module Maintenance The UPS battery life differ ...

  • APC 990-1587 - page 10

    8 5: T ROUBLESHOOTING Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.com with complex UPS problems. P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION UPS WILL NOT TUR N ON UPS not connected to utility power supply. Check that the po wer cord from the UPS to the utility power supply is se- curely connected a ...

  • APC 990-1587 - page 11

    9 P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION THE OVERLOAD LED IS ILLU MINATED AND THE UPS EMITS A SUSTAINED ALARM TONE The UPS is over loaded. The connected equipment is dr aw- ing more VA than the UPS can sustain. The connected equipment exceed s the specified “maximum load.” The alarm remains on until the overload is removed. Disconnect no ...

  • APC 990-1587 - page 12

    10 P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION BATTERY CHARGE AND LOA D LED BARGRAPHS FLASH SIMULT ANEOUSLY The UPS has shutdown. The internal temperat ure of the UPS has exceeded th e allow- able threshold for safe opera- tion. Check that the r oom temperature is within the specified l imits for operation. Check that the U PS is properly install ...

  • APC 990-1587 - page 13

    11 6: R EGULA TOR Y AND W AR RANTY I NFORMA TION 100V/120V models This equipment has been tested and fou nd to comply with the limits for a Class A digital device, pur- suant to part 15 of the FCC Rules. These li mits are designed to provide reason able protection agains t harmful interference when th e equipment is operated in a commercial environ ...

  • APC 990-1587 - page 14

    12 Limited Warranty American Power Conversion (APC) warrants its p roducts to be free from defects in materials and workmanship for a period of two years from the date of purchas e. Its obligation under this warranty is limited to repair ing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must ...

Fabricante APC Categoría Power Supply

Los documentos del dispositivo APC 990-1587 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos APC
- manuales de instrucciones 990-1587
- hojas de producto APC
- folletos informativos
- o etiquetas energéticas APC 990-1587
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones APC 990-1587.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje APC 990-1587, instrucciones de servicio, instrucciones cortas o instrucciones de usuario APC 990-1587. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto APC 990-1587.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo APC 990-1587, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar APC 990-1587. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de APC 990-1587.

El manual de instrucciones completo de APC debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual APC 990-1587 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice APC 990-1587, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de APC 990-1587 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo APC 990-1587 - que deben facilitarnos los primeros pasos durante el uso de APC 990-1587
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con APC 990-1587
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de APC 990-1587 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de APC 990-1587?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con APC 990-1587, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con APC 990-1587 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)