Manual de instrucciones Reliance Water Heaters 317686-000

40 de páginas 4.63 mb
Descargar

Pasar a la página of 40

Summary
  • Reliance Water Heaters 317686-000 - page 1

    1 Instruction Manual PRINTED 0810 317686-000 KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. ALL TECHNICAL AND W ARRANTY QUESTIONS: SH OU LD BE DIR EC TED T O THE LOCA L DE AL ER FROM WHO M TH E W A TE R HEA TE R W AS PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE T O THE COMP ...

  • Reliance Water Heaters 317686-000 - page 2

    2 SAFE INST ALLA TION, USE AND SERVICE The proper installation, use and servicing of this water heater is extremely important to your safety and the safety of others. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all saf ...

  • Reliance Water Heaters 317686-000 - page 3

    3 GENERAL SAFETY INFORMA TION ...

  • Reliance Water Heaters 317686-000 - page 4

    4 GENERAL SAFETY INFORMA TION at le as t 1 8" (4 5. 7 cm ) ab ov e th e floo r. This will reduce, but not eliminate, the ri sk ...

  • Reliance Water Heaters 317686-000 - page 5

    5 Thank Y ou for purchasing this water heater . Properly installed and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual: • CSA -CanadianStandards Association • ANSI- AmericanNationalStandardsInstitute • NFP A -NationalFireProtection ...

  • Reliance Water Heaters 317686-000 - page 6

    6 INST ALLA TION REQUIREMENTS FOR THE COMMONWEAL TH OF MASSACHUSETTS COMMONWEAL TH OF MASSACHUSETTS For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or o ...

  • Reliance Water Heaters 317686-000 - page 7

    7 PP SS (SEE ACCESS PA NE L CAUTION) W 6 (1 5 cm ) MA XIMU M AI R GA P TO A SUIT ABLE DRAI N TYPICAL INST ALLA TION * CAUTION HARNESS HAS 120 VAC. IN OPERATION. ** See “PLANNIN G THE VENT SYSTEM” , “CONDENSA TE” and “BLOWER ASSEMBL Y INST ALLA TION” for more information. *** The side recirculation loop connections may not be used as the ...

  • Reliance Water Heaters 317686-000 - page 8

    8 TYPICAL INST ALLA TION CONDENSA TE HOSE AND DRAIN P AN FIGURE 1A. ...

  • Reliance Water Heaters 317686-000 - page 9

    9 TYPICAL INST ALLA TION FIGURE 2. MIXING V AL VE / THERMAL EXP ANSION T ANK USAGE AND SP ACE HEA TING MIXING V AL VES DA NGER Wa ter temperatur e over 125° F (52°C) c an cause severe burns instantl y resulting in severe injury or death. Children, the elderly and the physically or mentally disabled are at highest risk for scald injury . Fe el wat ...

  • Reliance Water Heaters 317686-000 - page 10

    10 F ACTS TO CONSIDER ABOUT THE LOCA TION Car efull y cho os e an ind oor loca ti on for the new wate r hea te r , beca us e the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor inst ...

  • Reliance Water Heaters 317686-000 - page 11

    11 in an alcove or closet, the entire oor must be covered by the panel. Failuretoheedthiswarningmayresultinarehazard. Minimum clearances between water heater and combustible construction are 0 inch at the sides and rear , 5.5” (14.0 cm)? ...

  • Reliance Water Heaters 317686-000 - page 12

    12 Such a condition often will result in a yellow , luminous burner flame, causing sooting of the combustion chamber , burners and flue tubes and creates a risk of asphyxiation. Do not install the water heater in a conned space unless an adequate supply of air for combustion and ventilation is brought in to ...

  • Reliance Water Heaters 317686-000 - page 13

    13 Figure 7. The water heater should have clearances of at least 1 inch (25 mm) from the sides and back and 6 inches (15 0 mm) from the front of the appliance. The opening should directly communicate with the outdoors or should communicate through a vertical or horizontal duct to the outdoors or spaces t ...

  • Reliance Water Heaters 317686-000 - page 14

    14 T h i s w a t e r h e a t e r s h o u l d n o t b e c o n n e c t e d t o a n y h e a t i n g s y s t e m s o r co mpo nent(s )us edwit hanon -p otab lewaterh eatinga ppli ance. Al l pi ping co mpo nents c onne cted to thi s uni t fo r sp ace hea ting app lica tion s shoul d be suit abl e for use w ith p otabl e water . To x ...

  • Reliance Water Heaters 317686-000 - page 15

    15 THERMAL EXP ANSION As wate r is heate d, it exp ands  (therm al exp ansi on).  In a closed system the volume of water will grow when it is heated. As the volume of water grows there will be a corre spondi ng increa se in water pressure due to ther mal expa nsio n. Therm al expansi on can caus e pre matu re tan ...

  • Reliance Water Heaters 317686-000 - page 16

    16 discharge opening must not be blocked or reduced in size under any cir cum sta nces.  Exc ess iv e le ngt h, o ve r 30  fee t (9 .1 4 m) , or  use  of mo re tha n four el bo ws can ca use rest ri cti on an d redu ce th e disc ha rge capacity of the valve. No valve or other obstruction is to be placed between the ...

  • Reliance Water Heaters 317686-000 - page 17

    17 A g as l ine of suf f ic ient size mu st b e r un t o th e wate r he ater . Co nsult t he c urre nt edit ion of Na tion al Fuel G as Co de (A NSI Z 223 . 1/NFPA54)andyourga ssuppli erc once rni ngpipes ize. There must be: • A  readily accessible manual shuttoff valve in ...

  • Reliance Water Heaters 317686-000 - page 18

    18 N ev er us e th i s w a t er he at er un l es s it is co mp l e te ly fu ll of wa t er . To pr ev en t d a m a ge  to  t he  ta nk , t he  ta nk  mu st  be  l le d w it h w at er . W at er  mu st  o w fr om thehotwaterfaucetbeforeturning“ON”gastothewaterheate ...

  • Reliance Water Heaters 317686-000 - page 19

    19 TERMINA TION CLEARANCES SIDEW ALL POWER VENT V X VEN T TERMINAL AIR SUPPL Y INLE T A RE A WHERE TERMINAL IS NO T PERMITTED v v A G V FIXE D CLOSED FIXE D CLOSED OPERABLE OPERABLE V C B B B B F B V V A J V H M X X V V K B E D L POWER VENT (using room air for combustion) EXTERIOR CLEARANCES FOR SIDE WA LL VENT TERMINA TION FIGURE 15. V ent termina ...

  • Reliance Water Heaters 317686-000 - page 20

    20 PLANNING THE VENT SYSTEM Plan the route of the vent system from the discharge of the blower to the planned location of the vent terminal. Refer to V AA instruction on page 26 while planning the vent system. 1. Layout total vent system to use a m ini mum of vent pipe and elbows. 2. Thiswater heateris capableofventing ? ...

  • Reliance Water Heaters 317686-000 - page 21

    21 The condensate trap may be primed by lling the CONDENSA TE U-ASSEMB L Y with tap water while the water heater is not operating. The system is fully primed when the water level reaches the adaptor connected into the T ee. In most installations the water heater will self-prime thecondensate trap during? ...

  • Reliance Water Heaters 317686-000 - page 22

    22 CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA TION. VERIFY PROPER OPERA TION AFTER SERVICING. POWER VENT WIRING SCHEMA TIC - FIGURE 19. m a y b e e a si er to ma rk bo t h t h e i n si de an d ou t s i de wa ll . Al i g n h o le s by drilling a hole through center of ...

  • Reliance Water Heaters 317686-000 - page 23

    23 INST ALLA TION OF VENT SYSTEM, SIDEW ALL With the route of the venting system and selection of materials completed, as discussed in the section of this manual titled PLANNING THE VENT SYSTEM, the through the wallvent terminalin placeand therst section  of piping, up to rst elbow , in ...

  • Reliance Water Heaters 317686-000 - page 24

    24 VENT ATTENUA TI ON ASSEMBL Y IN S T A L L A TIO N I N S T R U CT IO NS The V ent Attenuation Assembly (V AA) is designed to provide a reduction in fan noise created in the blower wheel. This installation of this V AA is optional. Review directions thoroughly prior to installing the new V AA. Please contact the manuf ...

  • Reliance Water Heaters 317686-000 - page 25

    25 b a r b , u s e  a  w i r e  t i e  o r  h o s e c l a m p  (n o t s u p p l i e d  w i t h  k i t) and se cure. 6 . T a ke t h e o t h er e n d of t h e f l ex i b le t u bi n g a nd s l id e i t t hr o u gh the h ose c lamp o n the j acket top cover an d inst all it i nto one of the f our bar b f itt ings in ...

  • Reliance Water Heaters 317686-000 - page 26

    26 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designedforthespecicapplicationyouareattempting. B. Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use. C. Know the reputation of your manuf ...

  • Reliance Water Heaters 317686-000 - page 27

    27 B. Deburring  U se  a k n i fe , p l a s t i c p i p e de b u r r i ng  t oo l , o r  l e t o r e m o v e b ur r s f r o m t h e e nd o f s m a l l d ia m e t e r p i p e . Be s u re to re m o v e a l l b ur r s f r o m ar o u n d t he i ns i d e  a s  w e ll  a s  t h e  o u ts i d ...

  • Reliance Water Heaters 317686-000 - page 28

    28 ...

  • Reliance Water Heaters 317686-000 - page 29

    29 It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommended, in all cases, that the water temperaturebe set for thelowest temperature whichsatises your hot water needs. This will also provide the most energy efcient operat ...

  • Reliance Water Heaters 317686-000 - page 30

    30 FOR YOUR INFORMA TION ST ART UP CONDITIONS SMOKE/ODOR It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while. STRANGE SOUNDS Possib le noises due to expansi on and contract ion of some metal parts during periods of heat ...

  • Reliance Water Heaters 317686-000 - page 31

    31 BURNER OPERA TION AND INSPECTION Flood damage to a water heater may not be readily visible or immediately de te cta bl e. Ho wev er , ov era pe ri od  of  tim ea o od ed  wa ter  he at er w il l create dangerous conditions which can cause DEA TH, SERIOUS BODIL Y INJURY , OR PROPERTY  DAMAGE. ...

  • Reliance Water Heaters 317686-000 - page 32

    32 TEMPERA TURE-PRESSURE RELIEF V AL VE TEST D ANGER • Burn hazard . • Hot water discharge. • Ke ep clear of Te mperatur e- Pressure Relief Valve discharge outlet . It is recommended that the T emperature-Pressure Relief V alve should be checked to ensure that it is in operating condition every 6 months. Wh en ch ec ki ng th e T em pe ra tur ...

  • Reliance Water Heaters 317686-000 - page 33

    33 LEAKAGE CHECKPOINTS Neveruse thiswaterheater unlessit iscompletelylled withwater .  T o prevent damage to the tank, the tank must be lled with water .  W atermustowfromthe hotwaterfaucetbeforeturning“ON” gas to the wa ...

  • Reliance Water Heaters 317686-000 - page 34

    34 Key No. Part Description 1 Outer Door 2 Anode 3 Control Valve Assembly 4 Plastic T op 5 Blower Assembly 6 Switch and Harness Assembly 7 T&P V alve 8 Drain Valve 9 Wiring Harness 10 Anode Outlet 1 1 V ent Pipe Assembly #1 12 V ent Pipe Assembly #2 13 Vent Pipe Assembly #3 14 Inlet T ube 15 Pipe Nipple 16 Burner T ube Assembly 17 Hot Surface I ...

  • Reliance Water Heaters 317686-000 - page 35

    35 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Pleasecheckguidelinesbelow .Foryoursafety ,waterheaterserviceshouldbeperformedonlybyaqualiedservicetechnician. ReadtheGENERAL SAFETYINFORMA TIONsectionrst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL # LED ST A ...

  • Reliance Water Heaters 317686-000 - page 36

    36 # LED ST A TUS PROBLEM SOLUTION 7 8 9 Self diagnostic check has detected a problem with the gas valve driver circuit, internal microprocessor , or other internal circuits. 1 Turn the power of f for 10-20 seconds then on again to clear these error codes. 2 If any of these error codes persist or cannot be cleared - replace the gas control valve/th ...

  • Reliance Water Heaters 317686-000 - page 37

    37 Theseguidelinesshouldbeutilizedbyaqualiedserviceagent. TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES ...

  • Reliance Water Heaters 317686-000 - page 38

    38 TROUBLESHOOTING GUIDELINES NOTES ...

  • Reliance Water Heaters 317686-000 - page 39

    39 THIS W ARRANTY IS APPLICABLE T O THE ORIGINAL OWNER ONL Y . If the glass lined tank in this water heater shall prove upon examination by (the  warrantor) to have leaked during the warranty period in normal residential use, due to  natural corrosion from potabl ...

  • Reliance Water Heaters 317686-000 - page 40

    40 Copyright © 2010 Reliance W ater Heater Company . All rights reserved. www .reliancewaterheaters.com 500 T ennessee W altz Parkway Ashland Cit y, TN 37015 Te chnical Support 800-365-4054 Parts 800-821-2017 ...

Fabricante Reliance Water Heaters Categoría Water Heater

Los documentos del dispositivo Reliance Water Heaters 317686-000 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Reliance Water Heaters
- manuales de instrucciones 317686-000
- hojas de producto Reliance Water Heaters
- folletos informativos
- o etiquetas energéticas Reliance Water Heaters 317686-000
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Reliance Water Heaters 317686-000.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Reliance Water Heaters 317686-000, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Reliance Water Heaters 317686-000. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Reliance Water Heaters 317686-000.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Reliance Water Heaters 317686-000, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Reliance Water Heaters 317686-000. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Reliance Water Heaters 317686-000.

El manual de instrucciones completo de Reliance Water Heaters debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Reliance Water Heaters 317686-000 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Reliance Water Heaters 317686-000, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Reliance Water Heaters 317686-000 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Reliance Water Heaters 317686-000 - que deben facilitarnos los primeros pasos durante el uso de Reliance Water Heaters 317686-000
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Reliance Water Heaters 317686-000
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Reliance Water Heaters 317686-000 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Reliance Water Heaters 317686-000?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Reliance Water Heaters 317686-000, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Reliance Water Heaters 317686-000 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)