Manual de instrucciones Goldstar LWC061JGMK1

32 de páginas 1.36 mb
Descargar

Pasar a la página of 32

Summary
  • Goldstar LWC061JGMK1 - page 1

    ROOM AIR CONDITIONER SERVICE MANUAL CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. website: http://www.lgservice.com e-mail: http://www.lgeservice.com/techsup.html MODEL : M5403R, M5203R, M5203L, M6003R, WM-6011, LWJ0611PCG, LWC061JGMK1 D r y F a n C o o l ...

  • Goldstar LWC061JGMK1 - page 2

    —2— CONTENTS 1. PREF A CE ................................................................ 2 1.1 FEA TURES.................................................................. 2 1.2 SPECIFICA TIONS ...................................................... 3 1.3 SAFETY PRECA UTIONS ........................................... 3 1.4 INSULA TION RESIST A ...

  • Goldstar LWC061JGMK1 - page 3

    1.2 SPECIFICA TIONS • NO TE: Specifications are subject to minor change without notice f or fur ther improv ement. —3— MODELS ITEMS COOLING CAP ACITY (BTU/h) 5,300 5,200 5,200 6,000 6,000 PO WER SUPPL Y (Phase, V , Hz) 1ø , 115V , 60HZ INPUT (W) 530 470 610 620 OPERA TING CURRENT (AMP .) 4.8 4.3 5.6 5.8 REFRIGERANT CONTROL CAPILLAR Y TUBE RE ...

  • Goldstar LWC061JGMK1 - page 4

    —4— 1.5 LOCA TIONS OF CONTROLS 1.5.1 CONTROLS Dry Fan Cool ON/OFF TIMER - STOPPING OPERATION • Everytime you push this button, when the unit is operating, timer is set as follows. (1Hour 2Hours 3Hours 4Hours 5Hours 6Hours 7Hours 8Hours 9Hours 10Hours 11Hours 12Hours Cancel) • The Setting Temperature will be raised by 2 ° F(1 ° C) 30min. l ...

  • Goldstar LWC061JGMK1 - page 5

    — 5 — 1.5.2 REMO TE CONTROLLER How to Insert Batteries 1. Remov e the cover from the bac k of the remote controller 2. Inser t two batteries. • Be sure that the (+) and (-) directions are correct. • Be sure that both batteries are new . 3. Re-attach the cov er . • Do not use rechargeab le batter ies. Such bat- teries diff er from standard ...

  • Goldstar LWC061JGMK1 - page 6

    — 6 — 2. DISASSEMBL Y INSTR UCTIONS 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Disconnect the unit from source of power . 2. Using a screwdriv er , remov e the screw that secures the front grille to control board. (See Figure 1) 3. Push the front grille up from the bottom. Pull the top of the front grille aw a y from the cabinet as the top ta ...

  • Goldstar LWC061JGMK1 - page 7

    — 7 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.1.3) 5. Remov e 2 screws that secure the air guide upper to air guide lower . (See Figure 6) ...

  • Goldstar LWC061JGMK1 - page 8

    — 8 — 2.2.3 MO T OR 1. Disconnect the unit from the power source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.1.3) 5. Remov e the air guide upper . (Ref er to Section 2.2.1) 6. Remov e the compressor , turbo fan, f an and shroud. (Ref ...

  • Goldstar LWC061JGMK1 - page 9

    — 9 — 2.3.2 COMPRESSOR 1. Remov e the front grille and cabinet. (Ref er to Section 2.1.2) 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the overload protector . (Ref er to Section 2.3.1) 4. After discharging the unit completely , unbrace the suction and discharge pipes at the compressor connections. 5. Remov ...

  • Goldstar LWC061JGMK1 - page 10

    — 10 — 2.3.6 PO WER CORD 1. Disconnect the unit from source of power . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Remov e 2 screws that secure control board to base pan and orifice. 5. Pulls the control board tow ard you. 6. Remov e the grounding screw . 7. Remov e a screw securing ...

  • Goldstar LWC061JGMK1 - page 11

    2.4.3 CAPILLAR Y TUBE 1. Remov e the cabinet. 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the air guide upper . (Refer to Section 2.2.1) 4. After discharging the refrigerant completely , unbraze the interconnecting tube of the capillary tube. 5. Remov e the capillar y tube. 6. Re-install by ref erring to the pr ...

  • Goldstar LWC061JGMK1 - page 12

    — 12 — Equipment needed: V acuum pump , charging cylinder , manifold gauge, br azing equipment, pinch-off tool capable of making a vapor proof seal, leak detector , tubing cutter , hand tools to remov e components and ser vice v alve. B A B A B A COMPOUND GAUGE SEE INSETS BELOW CAPILLARY TUBE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CONDENSER ...

  • Goldstar LWC061JGMK1 - page 13

    — 13 — 3. INST ALLA TION This air conditioner is designed with a button-down chassis so it can be easily installed in a window . 3.1 SELECT THE BEST LOCA TION 1. T o prev ent vibration and noise, mak e sure the unit is installed securely and firmly . 2. Install the unit where the sun does not shine directly on the unit. 3. The outside of the ca ...

  • Goldstar LWC061JGMK1 - page 14

    — 14 — Installation 3.2.2 BEFORE INST ALLA TION 1. Inser t the guide panels into the guides of the air condi- tioner . F asten the cur tains to the unit with scre ws (TYPE A) as shown Figure . 24. 2. Cut the adhesive-bac ked seal strip (TYPE D) to the window width. Remov e the backing from the seal strip and attach the seal strip to the undersi ...

  • Goldstar LWC061JGMK1 - page 15

    3 . INST ALL THE AIR CONDITIONER IN THE WINDO W a. Carefully lift the air conditioner and slide it into the open window . Make sure the bottom guide of the air conditioner drops into the notches of the L brac ket. See Figure . 27. IMPORT ANT : When the air conditioner drops into the L brack et, the air conditioner will be centered in window opening ...

  • Goldstar LWC061JGMK1 - page 16

    — 16 — REMO V AL FROM WINDO W T ur n the air conditioner off, disconnect the po wer cord, remov e the L brac ket and the scre ws installed through the top and bot- tom of the guide panels, and sa ve f or reinstallation later. Close the guide panels . Keeping a firm grip on the air conditioner , raise the sash, and carefully tilt the air conditi ...

  • Goldstar LWC061JGMK1 - page 17

    — 17 — 4.2 PIPING SYSTEM F ollowing is a brief description of the impor tant components and their function in what is called the refrigeration system. Ref erence should be made to Figure 32 to f ollow the refrigerating cycle and the flow of the refrigerant in the cooling cycle. COOLED AIR HOT DISCHARGED AIR MOTOR COMPRESSOR ROOM AIR HEAT LOAD C ...

  • Goldstar LWC061JGMK1 - page 18

    — 18 — 4.3 TR OUBLESHOO TING GUIDE In general, possib le trouble is classified in tw o kinds. The one is called Starting Failure which is caused by an electrical defect. The other is Ineffective Air Con- ditioning caused by a def ect in the refrigeration circuit and improper application. Unit is running but cooling is ineff ective . Ineffective ...

  • Goldstar LWC061JGMK1 - page 19

    — 19 — Fails to Start Improper ther mistor setting Loose ter minal connection Improper wiring Check of po wer source. Drop of power v oltage. Capacitor check. Replacement. Check of control panel setting. Compressor f ails only to star t. Def ect of compressor capacitor . Replacement of compressor (Motor damaged). Irregular motor insulation ( ? ...

  • Goldstar LWC061JGMK1 - page 20

    — 20 — Is the Trans output power AC 115V? Is the Trans output power about AC 14V? Is shorted the Trans. output? Is output Voltage of IC01D DC 12V? Is output Voltage of IC02D DC 5V? Is the voltage No.20 of Micom DC 5V? Exchange Main P.W.B Ass'y. Is the connection between Main and Display all right? Is the reset circuit all right? (The No.16 ...

  • Goldstar LWC061JGMK1 - page 21

    — 21 — Is Temp. setting set lower than Room Temp.-0.5 ° C? Is the voltage No.11 of IC01M 0V? • Exchange IC01M. • Set the Temp. setting to higher Temp. • Wait 3 Minutes Is the Unit for 3 minutes delay? • Exchange MAIN P.W.B Ass'y. Is the voltage N0.6 of IC01M DC 5V? • Check the RY-COMP. • Check the wiring Diagram. NO NO NO NO Y ...

  • Goldstar LWC061JGMK1 - page 22

    — 22 — Is the voltage of Battery about over 2.3V? • Exchange Receiver Ass'y. Is the connection of CN-DISP2 all right? Is the voltage No.10 of CN-DISP2 on Main P.W.B Ass'y DC 5V? • Exchange the battery. • Check the P.W.B pattern. • Connect connector to CN-DISP2 exactly. NO NO NO YES YES YES P ossible T rouble 5 • Romote contr ...

  • Goldstar LWC061JGMK1 - page 23

    — 23 — ROOM AIR CONDITIONER V OL T A GE LIMITS NAME PLA TE RA TING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CA USE REMED Y F an motor will not run. No power Check v oltage at outlet. Correct if none. P ower supply cord Check v oltage to rotar y s witch. If none, check power supply cord. Replace cord if circuit is open. Rotar y s witc ...

  • Goldstar LWC061JGMK1 - page 24

    — 24 — COMPLAINT CA USE REMED Y F an motor noise. F an If crac ked, out of balance , or par tially missing, replace it. Blower If crac ked, out of balance , or par tially missing, replace it. Loose set screw Tighten it. W orn bear ings If knocking sounds contin ue when running or loose, replace the motor . If the motor hums or noise appears to ...

  • Goldstar LWC061JGMK1 - page 25

    — 25 — COMPLAINT CA USE REMED Y Compressor cycles on F an motor If not running, deter mine the cause. Replace if ov er load required. Condenser air flow Remo ve the cabinet, inspect the interior surf ace restriction of the condenser . If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush. Clean the inter ior base be ...

  • Goldstar LWC061JGMK1 - page 26

    — 26 — LOCA TION NO . 1 2 3 4 5 6 7 8 5. SCHEMA TIC DIA GRAM 5.1 CIRCUIT DIA GRAM • MODEL : M5403R, M5203R, M5203L, M6003R, WM-6011, L WJ0611PCG, L WC061JGMK1 Q'TY PER SET 1 1 1 1 1 1 1 1 DESCRIPTION PO WER CORD ASSEMBL Y F AN MO TOR COMPRESSOR DISPLA Y P .W .B ASSEMBL Y MAIN P .W .B ASSEMBL Y THERMIST OR CAP ACIT OR O WERLOAD PR O TECT ...

  • Goldstar LWC061JGMK1 - page 27

    — 27 — 5.2 ELECTRONIC CONTR OL DEVICE ...

  • Goldstar LWC061JGMK1 - page 28

    — 28 — 5.3 COMPONENTS LOCA TION (FOR MAIN P .W .B ASM) 5.4 COMPONENTS LOCA TION (FOR DISPLA Y P .W .B ASM) ...

  • Goldstar LWC061JGMK1 - page 29

    — 29 — 6. EXPLODED VIEW 135313 352390 267110 152302 130410 359012 W48602 135312 354210 349480 352380 149980 559011 346811 554030 W48602 130910 264110 238310 W0CZZ 249950 268714 263230 550140 554160 567502 352115 552111 352113 35211A 237200 268712 ...

  • Goldstar LWC061JGMK1 - page 30

    — 30 — 7. SER VICE P ARTS LIST LOCA TION NO DESCRIPTION REMARKS M5403R M5203R M5203L 130410 BASE ASSY , SINGLE 3041A10011E R 130910 CABINET ASSY ,SINGLE 3091A10020A R 135312 GRILLE ASSY , FRONT(SINGLE) 3531AR1644H 3531AR1644U R 135313 GRILLE ASSY , INLET 3530A10039A R 137215 P ANEL, CONTROL 3720A20017A 3720A20111A R 149980 SHR OUD 4998A10006A 4 ...

  • Goldstar LWC061JGMK1 - page 31

    — 31 — M6003R WM-6011 L WJ0611PCG L WC061JGMK1 130410 BASE ASSY , SINGLE 3041A10011E 3041A10011E 3041A10011E 3041A10011E R 130910 CABINET ASSY , SINGLE 3091A10020A 3091A10020A 3091A10020D 3091A10020D R 135312 GRILLE ASSY , FRONT(SINGLE) 3531AR1644H 3531AR1644T 3531AR1644T 3531AR1644T R 135313 GRILLE ASSY , INLET 3530A10039A 3530A10039A 3530A100 ...

  • Goldstar LWC061JGMK1 - page 32

    P/No.: 3828A20038B February, 2003 Printed in Korea ...

Fabricante Goldstar Categoría Air Conditioner

Los documentos del dispositivo Goldstar LWC061JGMK1 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Goldstar
- manuales de instrucciones LWC061JGMK1
- hojas de producto Goldstar
- folletos informativos
- o etiquetas energéticas Goldstar LWC061JGMK1
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Goldstar LWC061JGMK1.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Goldstar LWC061JGMK1, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Goldstar LWC061JGMK1. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Goldstar LWC061JGMK1.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Goldstar LWC061JGMK1, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Goldstar LWC061JGMK1. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Goldstar LWC061JGMK1.

El manual de instrucciones completo de Goldstar debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Goldstar LWC061JGMK1 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Goldstar LWC061JGMK1, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Goldstar LWC061JGMK1 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Goldstar LWC061JGMK1 - que deben facilitarnos los primeros pasos durante el uso de Goldstar LWC061JGMK1
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Goldstar LWC061JGMK1
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Goldstar LWC061JGMK1 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Goldstar LWC061JGMK1?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Goldstar LWC061JGMK1, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Goldstar LWC061JGMK1 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)