    INSTRUCTION AND PARTS BOOK FOR MODELS 526, 2900, & 4000 WOOD/COAL FURNACES Phone 715/654-5132 Fax 715/654-5513 07/97 Installation must be made in accordance with local and state codes which may differ from manual. Save these instructions. ...

  • Meyer 2900 - page 2

    2 We are constantly improving and updating our product in order to provide the highest quality and value possible. Consequently pictures might sometimes dif - fer slightly from the actual product. TRANSPORTATION DAMAGES Before reading this manual and proceeding with the installation, inspect your new Woodchuck to make sure there were no shipping da ...

  • Meyer 2900 - page 3

    3 TABLE OF CONTENTS Introduction..........................................................................................................................................................2 Table of Contents ................................................................................................................................................ ...

  • Meyer 2900 - page 4

    4 FURNACE SAFETY THERE ARE INHERENT HAZARDS ASSOCIATED WITH THE OPERATION OF WOOD/COAL FURNACES. FOR YOUR SAFETY READ, UNDERSTAND, AND HEED THE FOLLOWING: DANGER: RISK OF FIRE OR EXPLOSION. DO NOT BURN GARBAGE, GASOLINE, DRAIN OIL, OR OTHER FLAMMABLE LIQUIDS. FAILURE TO HEED MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH. DANGER: NEVER USE CHEMICAL ...

  • Meyer 2900 - page 5

    5 DISCLAIMER NOTICE The heating capacity specifications are provided as guidelines only and in no way guarantee the output or capacity of the units. The actual BTU output depends on the type of fuel being burned and its condition, the thermostat set - ting, the draft adjustments and the chimney that the unit is installed into. Height 42.5" Wid ...

  • Meyer 2900 - page 6

    6 GENERAL INFORMATION Woodchuck furnaces represent the ultimate in solid fuel and dual fuel heating appliances. From the massive model 4000 to the economy model 526, each unit is de - signed to be attractive, durable and efficient while pro - viding the safety and comfort you and your family deserve. HIGH QUALITY CONSTRUCTION Constructed of high gr ...

  • Meyer 2900 - page 7

    7 weather, it will not be large enough to keep the house warm in cold weather. This could cause the furnace to overheat and a loss of heat up the chimney. The result then is a compromise which is neither efficient or com - fortable. Woodchuck furnaces, however, have a three speed circulation blower which can be adjusted via a three position rotary ...

  • Meyer 2900 - page 8

    8 OPERATION COMMON SENSE Please read the following before firing your furnace. It is most important that you follow these suggestions and limitations in order to maintain your warranty and guar - antee the long life of your furnace. NOTE: Smoke detectors and fire extinguishers should always be a part of your equipment. This furnace is an airtight u ...

  • Meyer 2900 - page 9

    9 OPERATING YOUR WOODCHUCK FURNACE STARTUP Never leave ash pan in unit. Use only when cleaning out ashes. First thing is to check that your main blower and draft blower are in proper working order before lighting a fire. To check main blower, push button on fan/limit control for manual override testing. When finished, reset to au - tomatic position ...

  • Meyer 2900 - page 10

    10 the old type of pot belly stoves where the smoke pipe damper controlled the burning time. NOTE: With new steel, there is a small amount of oil or dirt on the metal and you may smell an odor. Provide adequate ventilating to home during the first operation. Your new Woodchuck is capable of putting out many BTU’s, so treat it with respect. Don’ ...

  • Meyer 2900 - page 11

    11 BURNING COAL IN YOUR WOOD - CHUCK Never attempt to burn coal without a shaker grate. Shaker grates are standard on Models 2900 and 4000 but optional on Model 526. A barometric draft control in the smoke pipe must be used when burning coal. CAUTION: UNSAFE TO LOAD COAL ABOVE TOP OF FIRE BRICK. STARTING A COAL FIRE Open all draft controls on your ...

  • Meyer 2900 - page 12

    12 ASH REMOVAL Ash should always be put into an air-tight, metal con - tainer. CAUTION · KEEP ASH PAN OUT OF UNIT DURING OPERA - TION. ASH PAN CAN GET VERY HOT. · ASH PAN MUST BE PLACED ON A NONCOMBUSTIBLE SURFACE. · NEVER USE ANYTHING BUT AN AIR TIGHT METAL CONTAINER TO DUMP YOUR ASHES IN. EVERY YEAR MANY FIRES ARE CAUSED BY EMPTYING ASHES INTO ...

  • Meyer 2900 - page 13

    13 PROBLEM POSSIBLE CAUSE SOLUTION 1. Main blower vibrating when in use. Loose Allen screw on squirrel cage. Bad motor bearings. Weights on squirrel cage wheel moved in ship - ment. Tighten Allen screw, be sure squirrel cage did not move to one side or the other. Return blower to your local dealer for a replacement. Try to adjust it yourself or ret ...

  • Meyer 2900 - page 14

    14 PROBLEM POSSIBLE CAUSE SOLUTION 9. Excessive amounts of smoke coming out loading door when loading. Improper draft. Chimney cap too close to top of chimney. Too long of run of smoke pipe from Woodchuck to chimney. Measure with draft gauge-should have .04 to .06 water column. Relocate. Relocate Woodchuck closer to chimney. 10. Puffing of smoke th ...

  • Meyer 2900 - page 15

    15 INSTALLATION GENERAL REQUIREMENTS CAUTION: EQUIPMENT MUST BE INSTALLED BY A QUALIFIED HEATING PERSON. CAUTION: ONLY “CLASS A” ALL-FUEL OR SOLID FUEL CHIM - NEYS INTENDED FOR USE WITH YOUR WOOD - CHUCK SHOULD BE USED. FIRST AND ABOVE ALL is safety for you and your family. MUST USE: Class A Masonry or ULC listed, manufac - tured Class A All Fu ...

  • Meyer 2900 - page 16

    16 FIGURE 8 TYPICAL CHIMNEY CHECKLIST CLEANOUT DOOR SHOULD BE PROVIDED AND IT MUST HAVE AN AIRTIGHT FIT. IT SHOULD NOT BE LEFT OPEN FOR ANY LENGTH OF TIME WHEN STOVE IS IN OPERATION FLUE SHOULD BE OF CONSTANT CROSS SECTIONAL AREA THROUGHOUT ITS LENGTH MIN. 3’ FROM TOP OF CHIMNEY TO POINT AT WHICH IT PASSES THROUGH THE ROOF RECOMMENDED MIN. HEIGHT ...

  • Meyer 2900 - page 17

    17 Your unit should be place on a non-combustible floor or 3/8" thick fireproof millboard or equivalent which ex - tends at least 8" from the sides and rear and extends 24" from the front. Leave a minimum clearance of 36" in front of your unit. This is for safe, easy loading and cleaning of your unit. Also be sure to allow enoug ...

  • Meyer 2900 - page 18

    18 When using approved factory built metal chimneys, you must have at least 2" of clearance when going through a wall or next to a wall. A typical factory chimney instal - lation is shown on figure 9. INSTALLING YOUR WOODCHUCK Most of the Woodchuck furnace is factory assembled. The factory assembly should be located as detailed in the PLACEMEN ...

  • Meyer 2900 - page 19

    19 FIGURE 10 A BAROMETRIC DRAFT REGULA - TOR AND ITS INTENDED EFFECT With no draft in chimney, regulator is closed, no air gets in. Moderate suction in chimney pulls regulator open enough to maintain desired draft for appliance. Excessive suction in chimney pulls regulator further open, allowing substantial air into chimney connector. MANUAL DAMPER ...

  • Meyer 2900 - page 20

    20 FIGURE 11 HOT AIR DUCT CLEARANCE REQUIREMENTS FIGURE 12 PARALLEL ADD-ON INSTALLATION FIGURE 13 CENTRAL ADD-ON INSTALLATION WOODCHUCK FINAL ASSEMBLY OPTIONAL SHAKER GRATE INSTALLATION FOR MODEL 526 1. Remove standard grates from firebox. Assemble com - plete shaker grate kit outside of unit. Figure 16. 2. Assemble the left front bar (different fr ...

  • Meyer 2900 - page 21

    21 4. Assemble the right front bar to a rear bar. Slide a gear onto the front shaft, aligning it to engage the gear on the left bar. Place the front bar onto the front frame and then setting the rear bar onto the rear frame. 5. Place rear retainer in place, then the center and the front retainers. Place all four bolts through retainers and frame. S ...

  • Meyer 2900 - page 22

    22 INSTALL FIREBRICK Place firebrick into unit as follows: 1. Place two longer bricks with bevel cuts against the rear wall of the firebox. See figure 17. 2. Place remaining two bricks with bevel cuts against the front wall of firebox. 3. Place rectangular brick along side walls of firebrick as illustrated. If Rectangular bricks are two different w ...

  • Meyer 2900 - page 23

    23 The pyrolysis of wood produces certain substances which will not burn unless the temperature in the firebox reaches 1000°F or higher. Under normal conditions these temperatures are not attained and these sub - stances simply escape up the chimney as wasted energy and can form deposits in the chimney. By forcing these unburned substances to come ...

  • Meyer 2900 - page 24

    24 THERMOCOUPLE WIRE INSTALL ALL CONTROL AND HANDLE KNOBS KNOCKOUT IN DRAFT CHANNEL REMOVED FORCED DRAFT BLOWER COMFORT CONTROL CENTER FAN/LIMIT CONTROL SECURE CONDUIT WITH CONDUIT CLAMPS AND #10 SHEET METAL SCREW FIGURE 20 INSTALL COMFORT CONTROL CENTER AND FORCED DRAFT BLOWER PRE-WIRED FLEXIBLE CONDUIT TO CIRCULATING BLOWER INSTALL CIRCULATING BL ...

  • Meyer 2900 - page 25

    25 ELECTRICAL HOOKUP (FIGURE 22) 1. If you have an optional temperature gauge to monitor heat exchanger temperature in your comfort control center, then the thermocouple wires must be connected to the gauge when installing the control. See figure 20. IMPORTANT : Remove the wire ground clip from the ter - minals of the gauge and connect White wire t ...

  • Meyer 2900 - page 26

    26 FIGURE 22 ELECTRICAL WIRING DIAGRAM W R WARNING: ELECTRICITY CAN KILL, SHOCK, OR BURN. DISCONNECT AND LOCKOUT POWER SOURCE BEFORE SERVICING OR INSTALLING ELECTRICAL COMPONENTS. FAILURE TO HEED MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH. CAUTION: ALL WIRING MUST MEET LOCAL, STATE AND NATIONAL CODES AND BE INSTALLED BY A QUALIFIED ELECTRICIAN. ...

  • Meyer 2900 - page 27

    27 KEY NO. PART NO. DESCRIPTION 1 01-0526 Welded Assembly 2 03-5262 Shroud - Right Side 3 03-5263 Shroud - Left Side 4 03-5261 Shroud - Top 5 08-0005 Circulation Blower 6 06-1001 Ash Pan 7 02-5261 Fuel Door 8 02-5262 Ash Door 9 06-1014 Door Knob 10 06-5261 Fuel Door Gasket 11 06-5262 Ash Door Gasket 12 06-0200 1/4 Door Pin 13 05-0004 Handle Access ...

  • Meyer 2900 - page 28

    28 KEY NO. PART NO. DESCRIPTION 1 01-2900 Welded Assembly 2 03-2901 Shroud - Top 3 03-2904 Shroud - Front 4 03-2902 Shroud - Right Side 5 03-2903 Shroud - Left Side 6 05-2908 Shaker Handle 7 06-1001 Ash Pan 8 06-1013 80/20 Selector Knob 9 06-0200 1/4" Door Pin 10 06-2903 Ash Door Gasket 11 02-2902 Ash Door 12 06-1014 Handle Knob (Large) KEY NO ...

  • Meyer 2900 - page 29

    29 KEY NO. PART NO. DESCRIPTION 1 01-4000 Welded Assembly 2 03-4001 Shroud - Top 3 03-2904 Shroud - Front 4 03-4003 Shroud - Left Side 5 03-4002 Shroud - Right Side 6 06-4001 Insulation - Side 7 06-2907 Insulation - Front 8 08-0005 Circulation Blower 9 06-1014 Handle Knob (Large) 10 06-1013 80/20 Selector Knob 11 06-1001 Ash Pan KEY NO. PART NO. DE ...

  • Meyer 2900 - page 30

    30 #05-5260-OPTIONAL SHAKER GRATE FOR MODEL 526 KEY NO. PART NO. DESCRIPTION 1 801-2520-1.25Z 1-1/2x1/4 Bolt 2 05-5265 End Retainer (S-5) 3 05-5266 Center Retainer (S-6) 4 05-5268 Rear Bar, Female (S-3) 5 05-5263 Front Bar, w/Extension (S-2-1) 6 05-5262 Front Bar, Male (S-2) 7 05-5264 Gears (S-4) 8 05-5267 Handle (S-7) 9 05-5261 Front Frame (S-1) 1 ...

  • Meyer 2900 - page 31

    31 CIRCULATING BLOWER #08-0090 COMPLETE BLOWER ASSY. KEY NO. PART NO. DESCRIPTION 1 08-0001 Motor 2 08-0002 Capacitor 3 08-0005 Blower Assembly (no motor) 4 08-0048 Electrical Connection Box 5 08-0004 Capacitor Boot 6 08-0003 Capacitor Bracket 7 08-0049 Electrical Box Cover 8 08-0005-2 Large Motor Mount Bracket 9 08-0005-3 Short Motor Mount Bracket ...

  • Meyer 2900 - page 32

    32 46-2900-8 Wiring Diagram ...

  • Meyer 2900 - page 33

    33 Model No. Of Unit Serial No. Of Unit Dealer Name Address Phone PERSONAL DATA INFORMATION FOR FUTURE REFERENCE q Filter Box q Shaker Grate q Domestic Coil Equipment Options Date Of Purchase Date Of Installation Name Of Installer Address Phone ...

  • Meyer 2900 - page 34

    34 This Page Intentionally Blank ...

  • Meyer 2900 - page 35

    LIMITED WARRANTY What is covered: Meyer Manufacturing Corporation warrants to the original owner only, all parts in this model Woodchuck solid fuel appliance to be free from defects in material and workmanship. For how long: For a period of one (1) year (from date of purchase) of normal use. Additional Coverage: In addition, Meyer Manufacturing Cor ...

  • Meyer 2900 - page 36

    MEYER MANUFACTURING CORPORATION P.O. Box 405 Dorchester, Wisconsin 54425 Manufactured By MEYER MANUFACTURING CORPORATION P.O. Box 405 Dorchester, Wisconsin 54425 ...

Fabricante Meyer Categoría Furnace

Los documentos del dispositivo Meyer 2900 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Meyer
- manuales de instrucciones 2900
- hojas de producto Meyer
- folletos informativos
- o etiquetas energéticas Meyer 2900
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Meyer 2900.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Meyer 2900, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Meyer 2900. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Meyer 2900.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Meyer 2900, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Meyer 2900. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Meyer 2900.

El manual de instrucciones completo de Meyer debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Meyer 2900 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Meyer 2900, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Meyer 2900 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Meyer 2900 - que deben facilitarnos los primeros pasos durante el uso de Meyer 2900
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Meyer 2900
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Meyer 2900 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Meyer 2900?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Meyer 2900, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Meyer 2900 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)