  • ResMed MIRAGE LIBERTY 61850/2 - page 1

    Global leaders in sleep and respiratory medicine www .resmed.com Mirage Liber ty™ FULL F ACE MASK User Guide English 61850/2 07 04 MIRAGE LIBER TY USER AP A C ENG 61850 61850r2 cover.qxp 3/04/2007 4:39 PM Page 1 ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 2

    ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA ResMed (UK) Ltd (EU Authorized Representative) 65 Milton Park Abingdon Oxfordshire OX14 4RX UK ResMed Offices Australia, Austria, Brazil, Finland, France, Germany , Hong Kong, Japan, M ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 3

    A Mask parts M i r a g e L i b e r t y ™ Mouth cushion Mask frame Ports cap Val ve Exhaust vents Upper straps Lower straps Lower clip B Fitting the mask 1 2 1 2 3 4 5 C Disassembling for cleaning 3 4 5 6 7 © 2007 ResMed Ltd. © 2007 ResMed Ltd. Inlet tube Swivel Nasal pillows Valve clip Right upper clip Lower clip Headgear parts Elbow Left upper ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 4

    D Reassembling the mask 1234 7 8 Mirag e Liberty F ull Face Mask Illustrations Sheet Note : F or complete instructions, please read the text section in conjunction with the illustrations on this sheet. Component of: 61850/2 5 E Reassembling the headgear 1 © 2007 ResMed Ltd. 9 6 © 2007 ResMed Ltd. 2 61850r2 illo sheets.qxp 3/04/2007 4:38 PM Page 2 ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 5

    Engli sh 1 Mirage Liber ty™ FULL FAC E MAS K T hank y ou fo r c hoosin g R esMed ’ s Mirage Liberty . Th e Mirage L iberty is a ful l face m ask th at comb i nes na sa l pi ll ows and a mou th cu shi on , c rea t ing a ma sk tha t is bo th u nob trusi ve and ea sy to us e wit hou t comp rom i sing se al, st a bil it y and co mfo rt. The mask in ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 6

    2 • An y suppl emental oxy gen flow must be turne d of f when the flow generato r is not operati ng, so th at unus ed o xygen d oes not accu mulate w ithin the flow generat or enc losure and create a risk of fire. • At a fixe d flow rat e of sup plementa l ox ygen flo w , the inha led o xygen conce ntration w ill vary , depend ing on the pressu ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 7

    3 Engli sh 5 T o tighte n or lo osen th e hea dgear s traps, pe el the V elc ro ® t ab of f the headg ear an d repos ition it. Gently and ev enly adj ust the upp er headge ar straps ( B-3 ), then t he lo wer stra ps ( B-4 ). Alterna te the a djustm ent of e ac h set of s traps unti l the y are com fo rt abl e and firm an d so that t he u pper head ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 8

    4 Note: You c an deta ch th e elb ow from the mask frame an d lea ve the mask on you r face. You ma y prefe r to do this w hen bri efly s toppin g thera py, for examp le to go to the bathroom. Disassembling the Mask See sec tio n C on th e illu str ations sh ee t. 1 Unclip the up per hea dgea r clips from th e frame ( C-3 ). 2 Careful ly pull th e ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 9

    5 Engli sh If the v ent requ ires c leani ng, use a sof t bris tle br ush. Rinse all com ponent s w ell w ith dri nking quality wa ter and al lo w them to a ir dr y out of direct su nlight. Weekly Handw ash the he adgea r b y gen tly r ubbing i n w arm ( 30°C) w a ter us ing m ild soa p or dilute d dish w ashing de tergent. Rinse the headge ar w e ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 10

    6 5 As sembl e th e elbo w ass embly : a P ush the t ab of the v alv e u p throug h the s lot in the v alv e clip ( D-7 ). Ens ure that the v alv e loc ks into the slot. b F eed the flap o f the v a lv e throu gh the slot i n the el bo w ( D-8 ). c Press th e valve cl ip ont o the el bow unt i l you hea r bot h s ide s cl ic k int o plac e ( D-9 ). ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 11

    7 Engli sh T r oubl eshooting P rob lem P ossible r eas on P oss ible solut ion Mask won ’t seal p roper ly or is un comf ortable Mouth cushio n o r pillows m ay be dirt y . Clean ma sk accord ing to instructions in “ Cle aning th e Mask in the Ho me ” . Mask may hav e been fit ted incorrectly . Carefully fo llow instruction s in “F it ting ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 12

    8 T ec hnical Specificat ions Note: The mask system does no t co nt ai n latex, PV C or DE HP ma ter ial s. Pre ssu r e– Fl ow C u rve Note: As a resu lt of manuf act uring v ar iation s, the v ent flo w ma y v ar y f rom that indi cated in the graph. Dead Sp ace Inf orm ation De ad sp ace i s the empty v olume of t he mas k up to the el bo w . T ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 13

    9 Engli sh Mask s ize s (e x clu des in let t ube and h eadge ar) S ymbols System and Pa ckaging User Gui de si ze widt h ( mm) he ight (mm) depth (mm) small 1 1 0 92 95 l a r g e 1 10 10 0 10 0 Caution , consult accomp any ing do cumen ts L ot nu mb er P art num be r/P roduc t co de No latex Humidity limit ation T emp era t ur e li mitation Manu f ...

  • ResMed MIRAGE LIBERTY 61850/2 - page 14

    10 Or der ing Infor mat ion Limit ed W ar r anty R esM ed w ar rants tha t y our R esM ed mas k sy stem , includ ing it s comp onents : mas k frame, cus hion, head gear , t ubing a nd other ac cess ories (“P rodu ct”) sh all be fre e from d ef ects in materi al an d w orkm anshi p f or a p eriod o f ninety (90) da y s from the date of purc hase ...

Fabricante ResMed Categoría Oxygen Equipment

Los documentos del dispositivo ResMed MIRAGE LIBERTY 61850/2 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ResMed
- manuales de instrucciones MIRAGE LIBERTY 61850/2
- hojas de producto ResMed
- folletos informativos
- o etiquetas energéticas ResMed MIRAGE LIBERTY 61850/2
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ResMed MIRAGE LIBERTY 61850/2.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ResMed MIRAGE LIBERTY 61850/2, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ResMed MIRAGE LIBERTY 61850/2. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ResMed MIRAGE LIBERTY 61850/2.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ResMed MIRAGE LIBERTY 61850/2, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ResMed MIRAGE LIBERTY 61850/2. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ResMed MIRAGE LIBERTY 61850/2.

El manual de instrucciones completo de ResMed debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ResMed MIRAGE LIBERTY 61850/2 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ResMed MIRAGE LIBERTY 61850/2, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ResMed MIRAGE LIBERTY 61850/2 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ResMed MIRAGE LIBERTY 61850/2 - que deben facilitarnos los primeros pasos durante el uso de ResMed MIRAGE LIBERTY 61850/2
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ResMed MIRAGE LIBERTY 61850/2
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ResMed MIRAGE LIBERTY 61850/2 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ResMed MIRAGE LIBERTY 61850/2?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ResMed MIRAGE LIBERTY 61850/2, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ResMed MIRAGE LIBERTY 61850/2 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)