    Frymaster, a member of the Co mmercial Food Equipm ent Serv ice Association, recommends using CFESA Certified Tec hnicians. MAR 2002 24-Hour Service Hotline 1-800-551-8633 *8195887* GF14 and GF40 Series Gas Fryers Installation & Operation Manual ...

  • Frymaster GF40 - page 2

    NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster DEAN Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s w ...

  • Frymaster GF40 - page 3

    DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restrainin ...

  • Frymaster GF40 - page 4

    i GF14 and GF40 SERIES GAS FRYERS TABLE OF CONTENTS CHAPTER 1: General Information 1.1 Parts Ordering and Service Information .............................................................. 1-1 1.2 Safety Information ............................................................................................... 1-2 1.3 Equipment Description ........ ...

  • Frymaster GF40 - page 5

    1-1 GF14 and GF40 SERIES GAS FRYERS CHAPTER 1: GENERAL INFORMATION 1.1 Parts Ordering and Service Information In order to assist you as quickly as possible, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requi res certain information about your equipm ent. Most of this information is printed on a data pl ...

  • Frymaster GF40 - page 6

    1-2 1.2 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations en closed in double-bordered boxes sim ilar to the ones below. CAUTION boxes contain information about actions or conditions that may cause or result in a malfunction of your system . CA ...

  • Frymaster GF40 - page 7

    1-3 The burner assembly can be configured for natural gas, propane, or manufactured gas, as required by the customer. A drain is tapped into the cente r of the frypot, with a front-controlled manual ball valve. Each fryer is equipped with a thermostat for precise tem perature control. The thermostat is located near the centerline of the frypot for ...

  • Frymaster GF40 - page 8

    1-4 1.6 Shipping Damage Claim Procedure Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsib ility for safe delivery upon acceptance of the equipment for transport. What to do if your equipment arrives damaged: 1. File a claim for damages immediately , regardless o ...

  • Frymaster GF40 - page 9

    2-1 GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2.1 General Installation Requirements PROPER INSTALLATION IN ACCORDANCE WITH TH E INSTRUCTIONS THAT FOLLOW IS ESSENTIAL FOR EFFICIENT, TROUBLE-FREE OPERAT ION OF YOUR FRYER. ANY UNAUTHORIZED ALTERATIONS MADE TO THIS EQUIPM ENT WILL VOID THE FRYMASTER WARRANTY. Upon arrival, in ...

  • Frymaster GF40 - page 10

    2-2 DANGER Do not attach an apron drainboard to a single fryer. The fry er may become unstable, tip over, and cause injury. The appliance area must be kept free and clear of combustible material at all times. NATIONAL CODE REQUIREMENTS The type of gas for which the fryer is equipped is ma rked on the data plate attached to the inside of the fryer d ...

  • Frymaster GF40 - page 11

    2-3 times when the fryer is in use. The restraining cable and installation instructions are packed with the flexible hose in the accessories box that was shipped with your unit. 2. These fryers must be stabilized by installing restra ining chains on fryers equipped with casters or anchor straps on fryers equipped with legs. Follo w the instructions ...

  • Frymaster GF40 - page 12

    2-4 1. Connect the quick-disconnect hose to the fryer qui ck-disconnect fitting at the rear of the fryer and to the building gas line. NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units are connected directly to the gas supply line. When using thread compound, use very sm all amounts on male threads only. Us ...

  • Frymaster GF40 - page 13

    2-5 Your fryer is configured at the factory for either natural gas or Propane (LP) gas. If you desire to switch from one type of gas to another, a Fact ory Authorized Service Center technician must install a gas conversion kit. Call Frymaster Service (1-800-551-8633) to determ ine the conversion kit appropriate for your configuration and altitude. ...

  • Frymaster GF40 - page 14

    3-1 GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS 3.1 Start-Up Procedure CAUTION If this is the first time the fryer is bei ng used after installation, refer to Section 3.2, Boil-Out Procedure. CAUTION The cooking oil/shortening capacity of the GF14 Series fry er is 40 lbs. (20 liters) at 70ºF (21ºC). The cooking oil/shortenin ...

  • Frymaster GF40 - page 15

    3-2 3. Push the knob in and light the pilot. Con tinue to hold the knob in for about 60 seconds after the flame appears on the pilot. Release the knob. The pilot should remain lit. CAUTION If the pilot fails to remain lit, wait five minutes before attempting to re-light. 4. With the pilot lit, push down a nd slowly turn the knob to the ON position ...

  • Frymaster GF40 - page 16

    3-3 6. Rinse the frypot at least twice by filling the fr ypot with clean water and draining. Dry the frypot thoroughly with a clean, dry towel. DANGER Remove all drops of water from the frypot before filling with cooking oil or shortening. Failure to do so may cause spattering of hot liquid when the oil or shortening is heated to cooking temperatur ...

  • Frymaster GF40 - page 17

    3-4 The thermostat is in the full OFF position when the word OFF is at the top of the knob. A “click” will be heard when the knob is rotated from the OFF position to a tem perature, or when it is rotated back to the OFF position. The thermostat may require calibration f rom time to tim e. To determine if it requires calibration, refer to Check ...

  • Frymaster GF40 - page 18

    3-5 NOTE: If draining the fryer to dispose of the cooking oil or shortening, Frymaster recommends the use of a wheeled disposal unit equipped with a pum p, such as the Frymaster SDU 50. When using a dispos al unit, follow the unit m anufacturer’s instructions. 2. Position a metal container with a sealable cover under the drain extension. The m et ...

  • Frymaster GF40 - page 19

    4-1 GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND OPERATOR TROUBLESHOOTING 4.1 Daily Checks and Services Inspect Fryer and Accessories for Damage Look for loose or frayed wires, leaks, foreign ma terial in frypot or inside cabinet, and any other indications that the fryer and accessories are not ready and safe for operation. ...

  • Frymaster GF40 - page 20

    4-2 Clean Detachable Parts and Accessories As with the frypot, a deposit of carbonized oil/shortening will accumulate on detachable parts and accessories such as baskets and sediment trays. Wipe all detachable parts and accessories with a clean cloth dam pened with a detergent solution. (Frymaster recomm ends the use of Frymaster Fryer ‘N’ Grid ...

  • Frymaster GF40 - page 21

    4-3 4. Reinstall tube and bend it so that the opening is pointing downward. 4.3 Semi-Annual Checks and Service Check Burner Manifold Pressure WARNING This task should be performed by qualified service personnel only . WARNING The frypot must be filled with water or cooking oil/shortening during this procedure. 1. Ensure that the gas valve knob is i ...

  • Frymaster GF40 - page 22

    4-4 5. If the burner manifold pressure does not meet the specifications in the tables in Step 4, unscrew the slotted cap from the top of the gas valve regulator (adjacent to the gas valve vent tube) and turn the adjusting screw to obtain the correct pr essure. Turn the screw clockwise to increase pressure, counter-clockwise to decrease pressure. 6. ...

  • Frymaster GF40 - page 23

    4-5 Problem Probable Cause Corrective Action A. Pilot is not lit. A. Light pilot. B. Loose, dirty, or corroded terminals on gas valve. B. Clean and tighten terminals on gas valve. C. Loose, dirty, or corroded terminals on thermostat. C. Clean and tighten terminals on thermostat. D. Thermostat, gas valve, or hi-limit wires broken or shorted. D. Exam ...

  • Frymaster GF40 - page 24

    4-6 Problem Probable Cause Corrective Action A. Too little make-up air in kitchen. A. Adjust kitchen ventilation system to increase make-up air. B. Pilot flame directed away from first orifice of burner. B. Reposition pilot hood to direct flame toward first burner orifice. C. One or more burner orifices clogged. C. Use a thin wire to clear obstruct ...

  • Frymaster GF40 - page 25

    4-7 Problem Probable Cause Corrective Action A. Loose, dirty or corroded hi-limit wires. A. Clean/tighten hi-limit wires on gas valve. Pilot remains lit when gas valve knob is pushed in, but goes out when released. B. If the above does not correct the problem, the probable causes are a weak gas valve pilot magnet, pilot generator low millivolt outp ...

  • Frymaster GF40 - page 26

    Frymaster, L.L.C., 8700 Line Av enue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Av enue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318- 219-71 40 FAX (Tech Support) 1-318-219-7135 Price: $5.00 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1-800-551-8633 819-5887 MAR 2002 ...

Fabricante Frymaster Categoría Fryer

Los documentos del dispositivo Frymaster GF40 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Frymaster
- manuales de instrucciones GF40
- hojas de producto Frymaster
- folletos informativos
- o etiquetas energéticas Frymaster GF40
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Frymaster GF40.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Frymaster GF40, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Frymaster GF40. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Frymaster GF40.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Frymaster GF40, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Frymaster GF40. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Frymaster GF40.

El manual de instrucciones completo de Frymaster debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Frymaster GF40 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Frymaster GF40, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Frymaster GF40 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Frymaster GF40 - que deben facilitarnos los primeros pasos durante el uso de Frymaster GF40
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Frymaster GF40
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Frymaster GF40 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Frymaster GF40?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Frymaster GF40, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Frymaster GF40 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)