Manual de instrucciones Heatcraft Refrigeration Products H-IM-FL1A

24 de páginas 0.62 mb
Descargar

Pasar a la página of 24

Summary
  • Heatcraft Refrigeration Products H-IM-FL1A - page 1

    H-IM-FL1A December , 2004 Part No. 25006901 Installation and Operation Manual T able of Contents General Safety Information ...................................................... 2 Inspection ................................................................................. 2 W arranty Statement ...................................................... ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 2

    2 © 2004, Heatcraft Refrigeration Products LLC General Safety Information 1. Installation and maintenance to be performed only by qualified personnel who are familiar with this type of equipment. 2. Some units are pressurized with dry air or inert gas. All units must be evacuated before charging the system with refrigerant. 3. Make sure that all ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 3

    3 The most important consideration which must be taken into account when deciding upon the location of air-cooled equipment is the provision for a supply of ambient air to the condenser , and removal of heated air from the condensing unit or remote condenser area. Where this essential requirement is not adhered to, it will result in higher head pre ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 4

    4 Figure 2. Solid Mount for Mobile or Deep Sump Application. Condensing Unit Rigging and Mounting Rigging holes are provided on all units. Caution should be exercised when moving these units. T o prevent damage to the unit housing during rigging, cables or chains used must be held apart by spacer bars. The mounting platform or base should be level ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 5

    5 Suction Filters, Driers, Sight Glasses There are two types of suction and liquid filter/driers used on Heatcraft Refrigeration Products units. Replaceable core and/or sealed units are used, dependent upon the option package ordered. Suction filters, regardless of type, are always installed upstream of the compressor suction service valve, and a ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 6

    6 Mineral Oils The BR and Scroll compressors use Sontex 200, a “white oil”. This oil is not suitable for low temperature applications nor is it available through the normal refrigeration wholesalers. For field “top-off” the use of 3GS or equivalent, or Zerol 200TD is permissible, as long as at least 50% of the total oil charge remains Sont ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 7

    7 Phase Loss Monitor The combination phase sequence and loss monitor relay protects the system against phase loss (single phasing), phase reversal (improper sequence) and low voltage (brownout). When phase sequence is correct and full line voltage is present on all three phases, the relay is energized as the normal condition indicator light glows. ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 8

    8 Liquid Lines Liquid lines should be sized for a minimum pressure drop to prevent “flashing”. Flashing in the liquid lines would create additional pressure drop and poor expansion valve operation. If a system requires long liquid lines from the receiver to the evaporator or if the liquid has to rise vertically upward any distance, the losses ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 9

    9 T able 5. Equivalent Feet of Pipe Due to V alve and Fitting Friction Copper T uber, O.D., Type “L” 1/2 5/8 7/8 1 1/8 1 3/8 1 5/8 2 1/8 2 5/8 3 1/8 3 5/8 4 1/8 5 1/8 6 1/8 Globe V alve (Open) 14 16 22 28 36 42 57 69 83 99 1 18 138 168 Angle V alve (Open) 7 9 12 15 18 21 28 34 42 49 57 70 83 90˚ T urn Through T ee 3 4 5 6 8 9 12 14 17 20 22 28 ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 10

    10 T able 6. Weight of Refrigerants in Copper Lines During Operation (Pounds per 100 lineal feet of type “L” tubing). Line Size Suction Line at Suction T emperature O.D. Liquid Hot Gas in Inches Refrigerant Line Line -40˚F -20˚F 0˚F +20˚F +40˚F 134a 4.0 .15 .01 .01 .02 .04 .06 3/8 22 3.9 .22 .02 .03 .04 .06 .08 R507, 404A 3.4 .31 .03 .04 . ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 11

    1 1 Line Insulation After the final leak test, refrigerant lines exposed to high ambient conditions should be insulated to reduce heat pickup and prevent the formation of flash gas in the liquid lines. Suction lines should be insulated with 3/4" wall Armstrong “Armaflex” or equal. Liquid lines should be insulated with 1/2 inch wall insu ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 12

    12 Field Wiring W ARNING: All wiring must be done in accordance with applicable codes and local ordinances. The field wiring should enter the areas as provided on the unit. The wiring diagram for each unit is located on the inside of the electrical panel door . All field wiring should be done in a profes - sional manner and in accordance with all ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 13

    13 NOTE: All adjustable controls and valves must be field adjusted to meet desired operation. There are no factory preset controls or valve adjustments. System Balancing - Compressor Superheat IMPORT ANT : In order to obtain the maximum capacity from a system, and to ensure trouble- free operation, it is necessary to balance each and every system. ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 14

    14 T able 7. System T roubleshooting Chart PROBLEM POSSIBLE CAUSES POSSIBLE CORRECTIVE STEPS Compressor will not run 1. Main switch open. 1. Close switch. 2. Fuse blown. 2. Check electrical circuits and motor winding for shorts or grounds. Investigate for possible overloading. Replace fuse after fault is corrected. 3. Thermal overloads tripped. 3. ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 15

    15 Preventive Maintenance Air Cooled Condensing Units Quarterly 1) Visually inspect unit • Look for signs of oil stains on interconnection piping and condenser coil. Pay close attention to areas around solder joints, building penetrations and pipe clamps. Check any suspect areas with an electronic leak detector . Repair any leaks found and add re ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 16

    16 Wiring Diagram for BACU51D2CHPQ 208V 14 AWG COMPRESSOR 1 M7 M8 FAN ARRANGEMENT COMP- 1 ALL COMPRESSORS THERMALLY PROTECTED COMPRESSOR 3 SEE COMPRESSOR ELECTRIC BOX COVERS FOR PROPER CONNECTION M4 M3 M5 M6 M1 M2 COMPRESSOR 2 ZR1 2 ZR19 COMP-3 COMP- 2 COMP-4 ENTRANCE ELECTRICAL COMPRESSOR 4 ZR16 ZR16 50 A C1 75 A C2 # 8 AWG 6 AWG # C4 60 A C3 60 A ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 17

    17 Wiring Diagram for BACU59D2CHPQ 208V 14 AWG COMPRESSOR 1 M7 M8 FAN ARRANGEMENT COMP-1 ALL COMPRESSORS THERMALLY PROTECTED COMPRESSOR 3 SEE COMPRESSOR ELECTRIC BOX COVERS FOR PROPER CONNECTION M4 M3 M5 M6 M1 M2 COMPRESSOR 2 ZR12 ZR19 COMP-3 COMP-2 COMP-4 ENTRANCE ELECTRICAL COMPRESSOR 4 ZR19 ZR19 50 A C1 75 A C2 # 8 AWG 6 AWG # C4 75 A C3 75 A # ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 18

    18 Control Circuit Wiring Diagram for BACU51 and BACU59 ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 19

    19 Submittal ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 20

    20 Submittal ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 21

    21 System Reference Data The following information should be filled out and signed by Refrigeration Installation Contractor at time of start-up. Date System Installed: _____________________________________________________ Installer and Address: _____________________________________________________ __________________________________________________ ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 22

    22 Notes ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 23

    23 Notes ...

  • Heatcraft Refrigeration Products H-IM-FL1A - page 24

    H EA TCRAFT R EFRIGERA TION P RODUCTS LLC 2175 W EST P ARK P LACE B OULEV ARD • S TONE M OUNT AIN , GA 30087 USA 770-465-5600 • F AX : 770-465-5990 WWW . HEA TCRAFTRPD . COM S inc e produc t im provem e nt i s a c ontinui n g ef for t , we re s er v e th e ri g ht to mak e c han g e s in sp e c i fi c ation s wi tho u t n o tice . V isi t us on ...

Fabricante Heatcraft Refrigeration Products Categoría Refrigerator

Los documentos del dispositivo Heatcraft Refrigeration Products H-IM-FL1A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Heatcraft Refrigeration Products
- manuales de instrucciones H-IM-FL1A
- hojas de producto Heatcraft Refrigeration Products
- folletos informativos
- o etiquetas energéticas Heatcraft Refrigeration Products H-IM-FL1A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Heatcraft Refrigeration Products H-IM-FL1A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Heatcraft Refrigeration Products H-IM-FL1A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Heatcraft Refrigeration Products H-IM-FL1A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Heatcraft Refrigeration Products H-IM-FL1A.

El manual de instrucciones del dispositivo Heatcraft Refrigeration Products H-IM-FL1A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Heatcraft Refrigeration Products H-IM-FL1A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Heatcraft Refrigeration Products H-IM-FL1A.

El manual de instrucciones completo de Heatcraft Refrigeration Products debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Heatcraft Refrigeration Products H-IM-FL1A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Heatcraft Refrigeration Products H-IM-FL1A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Heatcraft Refrigeration Products H-IM-FL1A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Heatcraft Refrigeration Products H-IM-FL1A - que deben facilitarnos los primeros pasos durante el uso de Heatcraft Refrigeration Products H-IM-FL1A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Heatcraft Refrigeration Products H-IM-FL1A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Heatcraft Refrigeration Products H-IM-FL1A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Heatcraft Refrigeration Products H-IM-FL1A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Heatcraft Refrigeration Products H-IM-FL1A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Heatcraft Refrigeration Products H-IM-FL1A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)