Manual de instrucciones TANDBERG D13202

32 de páginas 0.14 mb
Descargar

Pasar a la página of 32

Summary
  • TANDBERG D13202 - page 1

    Thi s docume nt i s no t to be re prod uced in w hol e or i n part with out the perm ission in writing from : TAND BE RG T ANDBER G GW Data port Comm and Interfa ce U ser Guide Softw a re version G1. 0 TANDBERG D13202 Rev 01 ...

  • TANDBERG D13202 - page 2

    TANDB E RG G W Datapo rt Comman d I nt er face User G uide D13202 Rev 01 2 Table o f Conten ts 1. INT RODUCTIO N .......... ........ ........ ....... ........ ............ ....... ........ ....... ........ ............ ....... ........ ............ 3 2. CONNECTING TO THE D ATAPORT COMM AND IN TERFACE THROUGH TH E RS- 232 POR T. ......... ........ . ...

  • TANDBERG D13202 - page 3

    TANDB E RG G W Datapo rt Comman d I nt er face User G uide D13202 Rev 01 3 1. Introduction The TANDBERG GW Datapo rt Comma nd Interface Use r Guide contains guideli nes on how to use t he textual command interface suppor ted by th e GW. The Dataport Command Interface can be accessed thro ugh Tel net via the LAN interface or through RS-232 by connec ...

  • TANDBERG D13202 - page 4

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 4 2. Connectin g to the D a taport Comm a nd Interface through th e RS-232 p o rt. Th e RS- 232 po rt is a 9 -pin, female, D- sub conn ector l oca ted on t he back of the GW. Th e port is configured as a DCE (Data Communications Eq uipment ) . The RS-232 port is default set to 960 ...

  • TANDBERG D13202 - page 5

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 5 2.2. Configuring The Dataport From The Web Interface Cl ic k on System Config uration tab and then the Dataport button. The Dataport can be configured b y setting baudr ate, parit y, databits and st opbi ts. 2. 3. Troubleshooting If communication cannot be established betw een t ...

  • TANDBERG D13202 - page 6

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 6 3. Connectin g to the D a tport Com mand I nterface u sin g Telnet The TANDBER G GW has two LAN port s. Co nnection to the Datapor t Command Int erface via Telnet should be done through LAN port 1. The GW’s Telnet server pro vides acce ss to the Dataport Command Interf ace thr ...

  • TANDBERG D13202 - page 7

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 7 4. The TANDBERG GW Commands 4.1. Introduction Typing ‘ ? ’ or ‘ help ’ when connected to the Dataport Command Interfac e wil l r eturn a list of valid comman ds. The commands are used to control the functi ons of the GW. A command may be foll owed by a set of pa rameters ...

  • TANDBERG D13202 - page 8

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 8 case where the user is trying to transfer a call f r om an inactive GW port (the user input is shown in bold). calltra nsfer 1 999999 *R Inva lid gateway id ERROR Parameter S etti ng Commands are commands that set a system parameter to a sp e cific value. E.g. : Th e comm a n d ...

  • TANDBERG D13202 - page 9

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 9 4.2.1. System Configuration Comm ands Comman d: Descript ion: defvalue s set This command is used to resto re factory def ault settings. Is s uing this command with no parameters will restore all settings except network settings and option key. To re set a l l val ues t o fac to ...

  • TANDBERG D13202 - page 10

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 10 Examp le of ipaddress fe edb ack : *P ipaddress 1 static 10.0.5.98 *P ipaddress 1 subnetmask 255.255.0.0 *P ipaddress 1 gateway 10.0.0.1 ipassi gnme nt Sele cts bet w ee n DH C P (D yna mi c Hos t Co nf i gur ati on P r ot o c ol) or sta ti c IP addr e s s allo cation. When DHC ...

  • TANDBERG D13202 - page 11

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 11 best a vai lab le sett in g. Examp le of ipspeed feedback: *P ipspeed 1 auto ipqos Configures the different Quality of Service (QoS) algorithms suppo rted by the TANDBERG GW. Q oS are used to set priorit y on QoS en able d IP networks. ipqos prectlph <chantype tlp h> < ...

  • TANDBERG D13202 - page 12

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 12 Examp le of ipq os feedb a c k: *P ipqos prect lp h audio auto *P i p qos diffstlph audio 0 *P ipqos pr ecvtlph audio auto *P ipqos precvt l ph signalling auto *P ipqos pr ecvtlph video auto *P ipqos precvt l ph data auto *P ip qo s di ff sv t lp h au di o 0 *P ipqos diffsvtlph ...

  • TANDBERG D13202 - page 13

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 13 --- par amet er s: • profil e number: p1 /p2/p3/p4/ p5/p6 . Th e GW can hold as ma n y as six profiles ( p1 , p2 and p3 are predefined and can no t be changed). • call pr ef ix: T he pr ef i x nu mbe r for t hi s pr of i le. • profile n ame: The profile’s name. Textstri ...

  • TANDBERG D13202 - page 14

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 14 prichan <PRI interface> lo w <1..23 / 31> or prichan <PRI interface> high <1..23/3 1> or prichan <PRI interface> s e arch <h i gh/ l ow> --- par amet er s: • PRI interface: a/b/c /d . Le tter s identi f ying the di ff erent PRI int erf aces ...

  • TANDBERG D13202 - page 15

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 15 o euro - Euro ISDN Examp le of prinet feedback: *P pr i net att prinu mbrange Defines the PRI number range fo r the various PRI interfaces . prin u mbrange <P RI interface> <lowes t nu mber> < highest num ber> --- par amet er s: • PRI interface: a/b/c /d . L ...

  • TANDBERG D13202 - page 16

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 16 *P service s http on *P serv ice s http s on *P servic e s snmp on *P servic e s ftp on se ndnum Enables/disables broadcast of the lo ca l unit’s number during H.320 ca ll setup. NOTE! The transfer of the l ocal number to a remot e system or the prevention thereof is dependen ...

  • TANDBERG D13202 - page 17

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 17 Examp le of sport feedback: *P sport 9600 n 8 1 syste mname Sets t he GW nam e. syste mname <n ame> --- Parameters: • nam e: Textstring of maximum 16 ch aracters. Examp le of syste mname feedback: *P syste mname TAND B E RG ...

  • TANDBERG D13202 - page 18

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 18 4. 2.2. G ene r al GW Comm ands Command: Desc ripti on: call transfer Disconnects t he h323 terminal of a GW call and reconnects to another h323 terminal, by ei t her spec ifying a tele p hone number or by referring to a direc t or y entry . calltran sfer <gwid> <numbe ...

  • TANDBERG D13202 - page 19

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 19 disc < gwid> --- pa rame ters: • gwid : 1. . 16. Identifier ref erring to a GW call. gwdi d Se t s ISDN DID (Di rect Inwa r ds Dial lin g) para meters. When DID is e nabled t he GW will s trip of the las t digits in the ISDN i ncoming nu mbe r and use this e xtracted nu ...

  • TANDBERG D13202 - page 20

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 20 gwh323ser vice <id> servprefix <e 164prefix> or gwh323service <id> maxbw <bw> or gwh323ser vice <id> isdncallprefix < callprefix> or gwh3 23 se rvice <id > re stri ct <on /of f > or gwh323ser vice <id> desc ri ption <desc ...

  • TANDBERG D13202 - page 21

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 21 or gwsetti ngs duovi deo <o n/off > or gwsettings encry ption <on/off > sub-c ommand s: • natvid : Sets natural vid e o supp ort to on o r off. • custo mformat s : Se t s cu st om for ma t su pp or t t o on or off • duovide o : Se ts d uo vi de o su pp or t t ...

  • TANDBERG D13202 - page 22

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 22 4.2.3. System Status Comm and s Comman d: Descript ion: callhi story Used t o list c all related information fo r the las t 20 calls. callh i story [logid] St at us fo rmat: callhistory <logid> <lo gtag> < gwlo gtag> <remote nu mb.> <call-dir> < ...

  • TANDBERG D13202 - page 23

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 23 chan st at Us ed to lis t ch anne l sta tus in form ation fo r the PRI int erfa ce. chansta t [pri interface] [channel] St at us fo rmat: chan st at < PRI in te rf ace > <c han nel > <ch ann e l - sta t us> <c a l l in g-n u mbe r > <ca useLoc>:< ...

  • TANDBERG D13202 - page 24

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 24 • h323 callid: The cal l id o f the h323 terminal • h323 termnumber: Th e nu mber of the h323 termin al Exampl e o f gwcalls fee dba ck: *S gwcalls 1 1 22222222 2 66666 666 h323gkstatus R etu rns cu rre nt g atek e epe r st atu s. h323gkstatu s St at us fo rmat: h323gkstatu ...

  • TANDBERG D13202 - page 25

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 25 off 0 ipcall stat isti cs Retu r ns IP dy na mic information fo r all activ e ip cal ls. ipcall sta tis tics St at us fo rmat: ipcal l statistics <callid> <protocol> <chantype> <direction> <rate> <sen t| rece i ved> < loss> <jitterms ...

  • TANDBERG D13202 - page 26

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 26 • PRI in terface: a/b/c /d. Letters identi f ying the di f ferent PRI interfaces. o a : PRI interface 1 o b : PRI i nterface 2 o c : P RI in terf ac e 3 o d : PRI i nterface 4 • st atu s : di s able d / r e d al ar m / b l ue al ar m/ y e llow al ar m / s y n c e d / active ...

  • TANDBERG D13202 - page 27

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 27 • vidres: unknown / cif / qcif / sqc if / 4cif / sif / 4sif / vga / svga / xga • duores: cif / qcif / sqcif / 4ci f / sif / 4sif / vga / svga / xga Exampl e o f stat out feed back : *S statout 1 outgo i ng synced norestrict h323-76 8 g722 h263 cif unknown *S statout 2 outgo ...

  • TANDBERG D13202 - page 28

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 28 4.2.4. Debug Commands Command: Desript ion: even tl og The eventlog records all serious erro rs regist ered by the s y st em. The log can be used to identify the cause for erro r s. The co mplete eventlog can be downloaded from the embedded FTP server. eventlog [n/all] Paramete ...

  • TANDBERG D13202 - page 29

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 29 6 146.172.254.249 (40 ms) 7 146.172.248.5 (40 ms) 8 146.172.248.9 (40 ms) 9 146.172.248.1 (40 ms) 10 146.172.248.62 (40 ms) 11 217.70.229.33 (40 ms) 12 213.248.78.1 (40 ms) 13 213.248.66.89 (40 ms) 14 213.248.65.25 (50 ms) 15 213.248.64.10 (150 ms) 16 12.122.10.49 (170 ms) 17 1 ...

  • TANDBERG D13202 - page 30

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 30 4. 2.5. S pec ial Com man ds Command: Descri ption: boot Reboots the sy stem. boot disp para m Lists all parameter settings. dis pparam fee dbac k Tu rns feed back on sy stem chan ges on / o ff. feedback [type] <on/off> --- Parameters : • type : para meter/ statu s Exam ...

  • TANDBERG D13202 - page 31

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 31 4.3. Parameter Storage Parameters are set by issuing Para meter Sett ing Co mmands, ref. ch apte r 4.1 .2 . All parameters and their co r re sponding storage type a re listed in the table b e low. The following def i ni ti ons a re use d: leve l 0: No storag e (RAM). Does not s ...

  • TANDBERG D13202 - page 32

    TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 32 4.4. Index Commands boot, 30 callhistory, 22 callst atus, 22 calltrans fer, 18 chanstat , 23 defval ues set , 9 dir e c tor y, 18 disc , 18 dispparam, 30 dumph221, 28 encsta t us, 23 even t log, 28 feedback, 30 gwcalls , 23 gwd i d, 19 gwextdialin, 19 gwh323service, 19 gwhotlin ...

Fabricante TANDBERG Categoría Network Router

Los documentos del dispositivo TANDBERG D13202 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos TANDBERG
- manuales de instrucciones D13202
- hojas de producto TANDBERG
- folletos informativos
- o etiquetas energéticas TANDBERG D13202
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones TANDBERG D13202.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje TANDBERG D13202, instrucciones de servicio, instrucciones cortas o instrucciones de usuario TANDBERG D13202. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto TANDBERG D13202.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo TANDBERG D13202, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar TANDBERG D13202. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de TANDBERG D13202.

El manual de instrucciones completo de TANDBERG debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual TANDBERG D13202 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice TANDBERG D13202, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de TANDBERG D13202 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo TANDBERG D13202 - que deben facilitarnos los primeros pasos durante el uso de TANDBERG D13202
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con TANDBERG D13202
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de TANDBERG D13202 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de TANDBERG D13202?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con TANDBERG D13202, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con TANDBERG D13202 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen