Manual de instrucciones Chicago Electric MIG 170

32 de páginas 4.64 mb
Descargar

Pasar a la página of 32

Summary
  • Chicago Electric MIG 170 - page 1

    Visit our website at: http://www .harborfreight.com Email our technical support at: tech@harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 201 1 by Harbor Freight T ools ® . All rights reserved. No portion of this manual or any artwork contained herein ma ...

  • Chicago Electric MIG 170 - page 2

    Page 2 For technical questions, please call 1-800-444-3353. SKU 68885 T able of Contents Safety ......................................................... 2 Setup .......................................................... 7 Specifications ............................................. 7 Basic Welding ............................................ 15 We ...

  • Chicago Electric MIG 170 - page 3

    Page 3 For technical questions, please call 1-800-444-3353. SKU 68885 Fume and Gas Safety FUMES AND GASES can be hazardous to your health. 1. Exposure to welding or cutting exhaust fumes can increase the risk of developing certain cancers, such as cancer of the larynx and lung cancer . Also, some diseases that may be linked to exposure to welding o ...

  • Chicago Electric MIG 170 - page 4

    Page 4 For technical questions, please call 1-800-444-3353. SKU 68885 Electrical Safety ELECTRIC SHOCK can KILL. 1. T urn off, disconnect power , and discharge electrode to ground before setting down torch/electrode holder and before service. 2. Do not touch energized electrical parts. Wear dry , insulating gloves. Do not touch electrode holder , e ...

  • Chicago Electric MIG 170 - page 5

    Page 5 For technical questions, please call 1-800-444-3353. SKU 68885 W elder use and care 1. Do not use the welder if the switch does not turn it on and off. Any welder that cannot be controlled with the switch is dangerous and must be repaired. 2. Disconnect the plug from the power source before making any adjustments, changing accessories, or st ...

  • Chicago Electric MIG 170 - page 6

    Page 6 For technical questions, please call 1-800-444-3353. SKU 68885 Grounding TO PREVENT ELECTRIC SHOCK AND DEA TH FROM INCORRECT GROUNDING WIRE CONNECTION: Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Have a plug installed by a certified electrician. Do not use the welder if the power cord ...

  • Chicago Electric MIG 170 - page 7

    Page 7 For technical questions, please call 1-800-444-3353. SKU 68885 Symbology Wire Feed (Speed) Workpiece Ground Cable T orch Cable Overheat Shutdown Indicator Cooling Fan Housing Ground Point V~ V olts Alternating Current A Amperes OCV Open Circuit V oltage K VA Kilovolt Amperes (V olts / 1000 * Amperes) IPM Inches Per Minute AW G American Wire ...

  • Chicago Electric MIG 170 - page 8

    Page 8 For technical questions, please call 1-800-444-3353. SKU 68885 1. Attach the handle to the Face Shield by lining up the two rectangular tabs on the handle with the corresponding holes in the face shield and A. press the tabs through the holes and then B. slide the tabs forward from the back, locking the round tab in place. 2. Wear heavy-duty ...

  • Chicago Electric MIG 170 - page 9

    Page 9 For technical questions, please call 1-800-444-3353. SKU 68885 Wire Spool Installation 1. T urn the welder OFF and unplug it before proceeding. 2. Pull up on the door latch, then open the Door . 3. Remove the Spool Knob, Spool Spring, and upper Spool Plate. If replacing a Spool, remove the old Spool and all remaining wire from the liners. 4. ...

  • Chicago Electric MIG 170 - page 10

    Page 10 For technical questions, please call 1-800-444-3353. SKU 68885 6a. Flux Core (Gas-less) Wire Setup: Remove the two Knobs securing the cables. Connect the Black Ground Cable to the rear , red, positive T erminal using the Knob. Connect the Red T orch Cable to the front, black, negative T erminal using the other Knob. This is the initial setu ...

  • Chicago Electric MIG 170 - page 11

    Page 1 1 For technical questions, please call 1-800-444-3353. SKU 68885 7. T urn the Feed T ensioner knob counterclockwise to loosen it enough to pull it down to remove tension. (Do not loosen the T ensioner knob too much, or the T ensioner will come apart.) Then, swing the Feed Swing Arm up. 8. Feed Roller Instructions: Check that the Feed Roller ...

  • Chicago Electric MIG 170 - page 12

    Page 12 For technical questions, please call 1-800-444-3353. SKU 68885 IMPORT ANT : Securely hold onto the end of the welding wire and keep tension on it during the following steps. If this is not done, the welding wire will unravel and create a tangled “bird’ s nest”, wasting wire. 9. Cut off all bent and crimped wire. The cut end must have ...

  • Chicago Electric MIG 170 - page 13

    Page 13 For technical questions, please call 1-800-444-3353. SKU 68885 W ARNING The following steps require applying power to the welder with the cover open. T o prevent serious injury from fire or electric shock: 1. Do not touch anything (especially not the Ground Clamp) with the T orch or welding wire, or an arc may be ignited. 2. Do not touch in ...

  • Chicago Electric MIG 170 - page 14

    Page 14 For technical questions, please call 1-800-444-3353. SKU 68885 17. T o check the wire’s drive tension, feed the wire against a piece of wood from 2 to 3 inches away . If the wire stops instead of bending, turn the welder OFF , unplug it, slightly tighten the feed tensioner clockwise, and try again. If the wire bends from the feed pressure ...

  • Chicago Electric MIG 170 - page 15

    Page 15 For technical questions, please call 1-800-444-3353. SKU 68885 Basic Welding Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before welding. TO PREVENT SERIOUS INJUR Y : Protective gear must be worn when using the Welder; minimum shade number 10 full face sh ...

  • Chicago Electric MIG 170 - page 16

    Page 16 For technical questions, please call 1-800-444-3353. SKU 68885 Control Panel Layout Overload Indicator: This lights up if duty cycle work period is exceeded, resulting in overheating the welder . Rest the T orch on an electrically non-conductive, heat-resistant surface, such as a concrete slab, well clear of the ground clamp while allowing ...

  • Chicago Electric MIG 170 - page 17

    Page 17 For technical questions, please call 1-800-444-3353. SKU 68885 A void damage to the Welder by not welding for more than the prescribed duty cycle time. The Duty Cycle defines the number of minutes, within a 10 minute period, during which a given welder can produce a particular welding current without overheating. For example, this Welder wi ...

  • Chicago Electric MIG 170 - page 18

    Page 18 For technical questions, please call 1-800-444-3353. SKU 68885 Metal Thickness Flux W eld Settings DCEN Polarity NO GAS Material Being Welded Wire T ype Shielding Gas Wire Diameter Suggested Settings 22 Ga .030″ 0.8mm 18 Ga .048″ 1.2mm 16 Ga .060″ 1.5mm 14 Ga .075″ 2.0mm 1/8″ 3.2mm 3/16″ 4.8mm 1/4″ 6.4mm Mild Steel Flux-core ( ...

  • Chicago Electric MIG 170 - page 19

    Page 19 For technical questions, please call 1-800-444-3353. SKU 68885 1. Make practice welds on pieces of scrap the same thickness as your intended workpiece to practice technique before welding anything of value. Clean the weld surfaces thoroughly with a wire brush or angle grinder; there must be no rust, paint, oil, or other materials on the wel ...

  • Chicago Electric MIG 170 - page 20

    Page 20 For technical questions, please call 1-800-444-3353. SKU 68885 DANGER! TO PREVENT DEA TH FROM ASPHYXIA TION: Do not open gas without proper ventilation. Fix gas leaks immediately . Shielding gas can displace air and cause rapid loss of consciousness and death. Shielding gas without carbon dioxide can be even more hazardous, because asphyxia ...

  • Chicago Electric MIG 170 - page 21

    Page 21 For technical questions, please call 1-800-444-3353. SKU 68885 1. Press (and hold) T rigger and contact area to be welded with electrode wire to ignite arc. 2. For a narrow weld, you can usually draw the wire in a steady straight line, this is called a stringer bead . For a wider weld, draw the wire back and forth across the joint, this is ...

  • Chicago Electric MIG 170 - page 22

    Page 22 For technical questions, please call 1-800-444-3353. SKU 68885 Note: If Welder is used too long, the amber Overload Indicator will light and the Welder T orch will shut off until the welder cools. If this happens, rest the T orch on an electrically non-conductive, heat-resistant surface, such as a concrete slab, well clear of the ground cla ...

  • Chicago Electric MIG 170 - page 23

    Page 23 For technical questions, please call 1-800-444-3353. SKU 68885 Welding T ips A good way to test welding technique is to examine a weld’s appearance after it has cooled and the slag has been removed. Then, better welding can be learned by adjusting your weld technique to remedy any problems found. A typical solid wire (GMA W) weld before c ...

  • Chicago Electric MIG 170 - page 24

    Page 24 For technical questions, please call 1-800-444-3353. SKU 68885 EXCESS PENETRA TION OR BURN-THROUGH PROPER PENETRA TION INADEQUA TE PENETRA TION Not hot enough T oo hot Ideal heat Weld Diagnosis W orkpiece Heat Control / W eld Penetration Good Weld Current T oo Low or Wire Feed T oo Slow Current T oo High or Wire Feed T oo Fast Weld Speed T ...

  • Chicago Electric MIG 170 - page 25

    Page 25 For technical questions, please call 1-800-444-3353. SKU 68885 EXCESS PENETRA TION OR BURN-THROUGH Weld droops on top and underneath, or falls through entirely , making a hole. PROPER PENETRA TION Weld is visible underneath and bulges slightly on top. INADEQUA TE PENETRA TION Weld does not contact the joint fully , just on the surface. POSS ...

  • Chicago Electric MIG 170 - page 26

    Page 26 For technical questions, please call 1-800-444-3353. SKU 68885 Burn-Through Base material melts away , leaving a hole in the weld. POSSIBLE CAUSES AND SOLUTIONS 1. Workpiece overheating: Reduce current and/or wire feed speed. 2. Welding speed too slow: Increase welding speed and ensure that welding speed is kept steady . 3. Excessive materi ...

  • Chicago Electric MIG 170 - page 27

    Page 27 For technical questions, please call 1-800-444-3353. SKU 68885 Maintenance TO PREVENT SERIOUS INJUR Y , FIRE AND BURNS: Unplug the welder , rest the T orch on a heat-proof, electrically non-conductive surface, and allow all parts of the Welder to cool thoroughly before service. 1. Periodically remove the Side Panel, and using compressed air ...

  • Chicago Electric MIG 170 - page 28

    Page 28 For technical questions, please call 1-800-444-3353. SKU 68885 T roubleshooting IMPORT ANT! Be CERT AIN to shut off the Welder , disconnect it from power , and discharge the T orch to ground before adjusting, cleaning, or repairing the unit. Wire feed motor runs but wire does not feed properly POSSIBLE CAUSES AND SOLUTIONS 1. Insufficient w ...

  • Chicago Electric MIG 170 - page 29

    Page 29 For technical questions, please call 1-800-444-3353. SKU 68885 T roubleshooting (continued) IMPORT ANT! Be CERT AIN to shut off the Welder , disconnect it from power , and discharge the T orch to ground before adjusting, cleaning, or repairing the unit. Power switch lights, but welder does not function when switched on POSSIBLE CAUSES AND S ...

  • Chicago Electric MIG 170 - page 30

    Page 30 For technical questions, please call 1-800-444-3353. SKU 68885 Parts List and Diagrams Wiring Diagram Gas/Gasless Gasless Welding T orch Gas Ground Clamp Welding T orch Switch Parts List Record Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for ill ...

  • Chicago Electric MIG 170 - page 31

    Page 31 For technical questions, please call 1-800-444-3353. SKU 68885 Assembly Diagram 12345678 9 10 11 12 13 14 32 31 30 29 28 27 26 25 15 16 17 18 19 20 21 22 23 24 33 35 36 37 34 SAFETY MAINTENANCE BASIC WELDING WELDING TIPS SETUP ...

  • Chicago Electric MIG 170 - page 32

    3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 9301 1 • (800) 444-3353 Limited 90 Day W arranty Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of ...

Fabricante Chicago Electric Categoría Welder

Los documentos del dispositivo Chicago Electric MIG 170 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Chicago Electric
- manuales de instrucciones MIG 170
- hojas de producto Chicago Electric
- folletos informativos
- o etiquetas energéticas Chicago Electric MIG 170
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Chicago Electric MIG 170.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Chicago Electric MIG 170, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Chicago Electric MIG 170. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Chicago Electric MIG 170.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Chicago Electric MIG 170, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Chicago Electric MIG 170. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Chicago Electric MIG 170.

El manual de instrucciones completo de Chicago Electric debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Chicago Electric MIG 170 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Chicago Electric MIG 170, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Chicago Electric MIG 170 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Chicago Electric MIG 170 - que deben facilitarnos los primeros pasos durante el uso de Chicago Electric MIG 170
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Chicago Electric MIG 170
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Chicago Electric MIG 170 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Chicago Electric MIG 170?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Chicago Electric MIG 170, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Chicago Electric MIG 170 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)