    Installation and Operation Instructions GF 3 BV ALLAGASH B-Vent Gas Heater WARNING: IF THE INFORMA TION IN THESE INSTRUCTIONS ARE NO T FOLLO WED EXA CTL Y , A FIRE OR EXPLOSION MA Y RESUL T CA USING PROPER TY D AMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR Y OUR SAFETY : DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICI ...

  • Jøtul GF 3 BV - page 2

    THIS STO VE IS SHIPPED AS A N A TURAL GAS S TO VE ONL Y . IF USE WITH PR OP ANE IS DESIRED , THE STO VE MUST BE CONVER TED TO USE WITH PR OP ANE. FOR Y OUR CONVENIENCE THE STO VE IS SHIPPED WITH A PR OP ANE CONVERSION KIT . Model: Allag ash B-V e nt Gas Sto ve Manufactured and Distributed by: Jøtul A.S .A. F redrikstad, Norwa y Jøtul North Americ ...

  • Jøtul GF 3 BV - page 3

    3 28 22 3/4 WELCOME TO JØTUL: Congratulations on the purchase of your new Jøtul gas stov e . W e a t Jøtul are very happy y ou ha v e made the decision to warm your hearth with a Jøtul product. Y our new Jøtul Allagash has inherited the benef its learned from more than 140 years of producing stov es. Jøtul is the wo rld s largest man ...

  • Jøtul GF 3 BV - page 4

    STAND ARDS : This appliance complies with National Safety standards and is tested and listed by ITS , Intertek T esting Services Middleton, WI In addition, the Allagash gas stove complies with and has been tested and listed as a gra vity v ented gas fieplace heater and listed to: ANSI Z21.88-1998(NFP A 54) CSA 2.33-M98 for Canada. DO NOT A TTEMPT T ...

  • Jøtul GF 3 BV - page 5

    THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FL UE SER VING ANY OTHER APPLIANCE OF ANY KIND . L OCA TION : In selecting the location, the aesthetic and functional use of the appliance are primary concer ns; How ev er , proper venting systems and access to the fuel supply are also important issues. Due to the high surface temperatures of the ...

  • Jøtul GF 3 BV - page 6

    ST O VE CLEARANCES: Minimum clearances for the Alla g ash B-V ent gas stove are as follows: Rear clearance =2(50mm) (measured from draft hood) Ceiling =18(460mm) (measured from top of stove) Corner clearance = 3(76mm) (measured from rear corners) Right side clearance = 4(102mm) Left side clearance = 10 (255mm) (for access to the ligh ...

  • Jøtul GF 3 BV - page 7

    VENTING REQUIREMENTS: The Allagash is specifically designed to operate using 4 Type B vent pipe components or a Listed Flex ible gas liner . FOLLO W THE GUIDELINES LISTED BELO W FOR THE PROPER VENTING OF THE ALLAGASH B-VENT STO VE!  All venting components must be installed in accordance with the terms of their listing and manu facturer s i ...

  • Jøtul GF 3 BV - page 8

     When decorative 6 pipe is installed to cover the venting any Listed Flexible Gas liner must be connected directly to the stov e s draft hood.  Use of single wall connector pipe as a vent is prohibited for use with the Allagash B-V ent stove.  A firestop is required at every f loor .  Any venting that is exposed above the first fl ...

  • Jøtul GF 3 BV - page 9

    9 Maximum horizontal offset anywhere in venting configuration is 4 feet. Minimum chimney height off draft hood = 7 feet . Listed B-V ent termination cap required. Listed B-V ent termination cap required. Minimum chimney height off draft hood = 7 feet . Maximum total horizontal offset anywhere in venting configuration is 4 feet. 45° or 90° elbow 4 ...

  • Jøtul GF 3 BV - page 10

    GAS CONVERSION: The Allagash B-V ent gas stov e is shipped from the factor y equipped as a N A TURAL GAS unit; Ho w ever , the stov e is shipped with the necessar y gas conv ersion kit to con v er t the stov e to burn PR OP ANE GAS . These kits contain all the necessary components needed to complete the task and ensure safe operation, including lab ...

  • Jøtul GF 3 BV - page 11

    8. Adjust the air shutter on the burner tube to allow for the proper mixing of air and gas. See Figure 2. The correct settings: natural 1/4 open propane 1/4 open WHEN RE-INST ALLING THE BURNER TUBE BE SURE THA T THE TUBE IS PULLED FOR W ARD IN THE MOUNTING HOLES, SECURE WITH THE TWO 1/4 SCREWS. 9. Change the pilot orifice. FR OM WITHIN THE ...

  • Jøtul GF 3 BV - page 12

    Secure all joints tightly using appropriate tools and sealing compounds (for propane units , be sure to use compounds that are propane resistant). Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for leaks. Leak test: · Mix a 50-50 solution of water and dish soap . · Light appliance- see lig ...

  • Jøtul GF 3 BV - page 13

    The appliance must be isolated from the gas supply line by closing its individual manual gas shut-off valve (gas cock) during any pressure testing of the gas supply piping system that is equal to or exceeds pressures of 1/2 psig (3.5kPa). NECESSAR Y INLET GAS PRESSURES (inches water column) MIN MAX N A TURAL GAS 5.0 W C 7.0 W C PR OP AN E 11.0 W C ...

  • Jøtul GF 3 BV - page 14

    Derating procedure 1.T o derate this unit, install the appropriate ori- fice per the High Altitude chart. 2.Remove the two ¼ hex head screws that hold the burner tube/log support to the bottom of the stov e . 3.Remove the burner tube/log support to expose the main burner orifice . 4.Remove the orifice and replace with the appropriate one from t ...

  • Jøtul GF 3 BV - page 15

    INSTALLING THE LOG SET : The Allagash is equipped with a one piece log set and is packaged in bubble wrap inside the firebox. The log set must be removed from the packaging and arranged in the unit prior to start up of the gas stov e . Do not handle the log set with your bare hands. Always wear gloves to prevent skin irritation from the ceramic fib ...

  • Jøtul GF 3 BV - page 16

    INST ALLING THE OPTION AL BL O WER: IMPOR T AN T : IF THE OPTION AL FOR CED AIR BLO WER KIT (part # 129161) IS TO BE INST ALLED ON THE STO VE A T THE TIME OF THE INST ALLA TION OR IN THE FUTURE, THE GAS SUPPL Y LINE SHOULD BE INST ALLED AS CLOSE TO THE FLOOR AS POSSIBLE. USE OF A 90° ELBO W DIRECTL Y OFF THE V AL VE WILL ALLO W FOR PR OPER CLEARAN ...

  • Jøtul GF 3 BV - page 17

    INST ALLING THE OPTION AL W ALL THERMOST A T OR REMO TE : When installing a wall mounted thermostat to the Alla gash, it must be a 750 millivolt DC tw o - wire circut thermostat . The thermostat should be placed in the same room as the heater , typicall y 5 off the f loor . A void drafty areas or any area that may effect the accuracy of the ther ...

  • Jøtul GF 3 BV - page 18

    CHECKING THE SYSTEM: 1. PUR GING THE GAS LINE: When lighting the appliance for the first time it will take a f ew moments to clear the gas line of air . Once this purge is complete , the appliance will operate as described in the lighting instr uctions located on the stov e s rating plate and the back cov er of this manual. All subsequent lighti ...

  • Jøtul GF 3 BV - page 19

    OPERA TION OF APPLIANCE: 1. The Allagash B-V ent gas sto v e is equipped with an On/Off/T-stat rocker switch or can be controlled using an optional wall- mounted thermostat. A separate switch is provided for the optional forced air blower kit. 2. When lit for the first time , the Allagash will emit an odor for several hours . This odor is the burn- ...

  • Jøtul GF 3 BV - page 20

    20 SER VICE L OG : First Y ear Name of T ec hnician__________________ Company Name______________________ Date of service_______________________ W ork Per formed______________________ __________________________________ SER VICE L OG : Tw o Y ear Name of T echnician__________________ Company Name_____________________ Date of service__________________ ...

  • Jøtul GF 3 BV - page 21

    21 9 Door Pins 125960 10 Glass Clips 129135 11 Glass Assembly 154337 * Glass Panel only 1291 13 * Gasket only (7/16 tadpole) 129124 (6ft.) 12 Log Set 129122 13 Burner Tube 129121 * Embers 129123 14 Log Support 129132 15 Air Divider 129320 16 Air Deflector 129109 17 Exhaust Baffle 129310 18 Firebox 129180 * Latch Keeper 129149 19 Heat Exchanger Gask ...

  • Jøtul GF 3 BV - page 22

    23 24 22 21 20 19 5 4 18 17 16 28 25 26 27 4 15 6 14 10 3 9 2 1 29 7 11 30 13 12 GF3 BV Allagash Illustrated Parts Breakdown 22 ...

  • Jøtul GF 3 BV - page 23

    8. Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (push the red button repeatedly) until pilot lights. Continue to hold the control knob in for about one minute after the pilot lights. Release knob and it should spring back. The pilot should remain lit. If it goes out, repeat S teps 5 throu ...

  • Jøtul GF 3 BV - page 24

    Stoves and fireplaces must be installed to conform to local and national building regulations. Before preparing for the installation of the appliance, it is important that the instructions issued with the unit are carefully read an strictly adhered to. Jøtul pur sues a policy of constant product development. Products supplied may therefore differ ...

Fabricante Jøtul Categoría Gas Heater

Los documentos del dispositivo Jøtul GF 3 BV que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Jøtul
- manuales de instrucciones GF 3 BV
- hojas de producto Jøtul
- folletos informativos
- o etiquetas energéticas Jøtul GF 3 BV
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Jøtul GF 3 BV.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Jøtul GF 3 BV, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Jøtul GF 3 BV. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Jøtul GF 3 BV.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Jøtul GF 3 BV, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Jøtul GF 3 BV. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Jøtul GF 3 BV.

El manual de instrucciones completo de Jøtul debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Jøtul GF 3 BV - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Jøtul GF 3 BV, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Jøtul GF 3 BV que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Jøtul GF 3 BV - que deben facilitarnos los primeros pasos durante el uso de Jøtul GF 3 BV
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Jøtul GF 3 BV
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Jøtul GF 3 BV en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Jøtul GF 3 BV?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Jøtul GF 3 BV, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Jøtul GF 3 BV probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)