  • Aprilaire 1953 & 1972 - page 1

    Safety , Installation and Ser vice Manual Models 1 952 , 1 953 & 1 972 Ultraviolet Germicidal Lamps READ AND SA VE THIS MANUAL Model 1952 24” Rooftop Unit Model 1953 32” Rooftop Unit Model 1972 Rooftop Unit, Internal Mount ...

  • Aprilaire 1953 & 1972 - page 2

    2 I. SAFETY INSTRUCTIONS WARNING Ultraviolet light is harmful to eyes and skin. Never look at light produced by this lamp. Shut off power to lamp before servicing. Electrical shock from 120 - 277 V AC may cause serious injury . Shut off power before starting installation and do not turn power back on until complete. Sharp edges may cause personal i ...

  • Aprilaire 1953 & 1972 - page 3

    3 II. APPLICA TION Models 1952, 1953, and 1972 Aprilaire Ultraviolet Germicidal Lamps are designed for the treatment of evaporator coils used in rooftop HV AC air handling units or in larger split systems used in the light commercial market. The UV germicidal light emitted from the lamps will kill microorganisms growing on evaporator coils and drai ...

  • Aprilaire 1953 & 1972 - page 4

    4 INST ALLA TION OF EXTERNAL MOUNT ROOFTOP UNITS (MODELS 1952 & 1953) a. The lamps are intended for evaporator coil treatment. See Figure 2 for typical installation. If a single Lamp cannot illuminate the majority of the evaporator coil, two or more units might be required as shown. T o the extent possible, the Lamp(s) should be centered on the ...

  • Aprilaire 1953 & 1972 - page 5

    5 INST ALL THE UNIT BASE 1. Using the Unit Base as a guide, mark the locations for the lamp and mounting holes on the rooftop unit cabinet. 2. Carefully inspect the inside of the rooftop unit and make sure that no damage to any components will occur as a result of drilling the holes. 3. Drill hole for the lamp using a 2 in. hole cutter . At the mou ...

  • Aprilaire 1953 & 1972 - page 6

    6 INST ALL LAMP 1. Remove Lamp from shipping tube. Use ceramic ends of Lamp when handling – do not touch the glass tube of Lamp. Use alcohol to remove any dirt and/or fingerprints from the Lamp. 2. Referring to Figure 4, follow the steps below to install Lamp: a. First, with the Lamp Retaining Bracket removed, slide the Lamp into the large side o ...

  • Aprilaire 1953 & 1972 - page 7

    7 INST ALLA TION OF INTERNAL MOUNT ROOFTOP UNITS (MODEL 1972) Wiring Access Cover Mounting Brackets Lamp Socket Lamp FIGURE 5 – Model 1 972 90-744 CHECK LAMP OPERA TION The preferred method for checking lamp operation is to measure the current draw of the lamp using a clamp-on ammeter . T o detect the low current of the UV lamp, the ammeter must ...

  • Aprilaire 1953 & 1972 - page 8

    8 a. The lamps are intended for evaporator coil treatment. See Figure 6 for typical installations. If a single Lamp cannot illuminate the majority of the evaporator coil, two or more units might be required. T o the extent possible, the Lamp(s) should be centered on the coil (or section thereof) being illuminated. Note that a Model 1972 Internal Mo ...

  • Aprilaire 1953 & 1972 - page 9

    9 3A Fuse Ground Y ellow (2) NO T USED Ballast Lamp Sock et Red (2) Blue (2) White Black Green Green Black 120V AC to 277V AC P ower Source White Interlock switches (not provided) recommended for all access panel doors FIGURE 7 – Model 1972 Wiring Diagram 90-754 INST ALL LAMP 1. Remove Lamp from shipping tube. Use ceramic ends of Lamp when handli ...

  • Aprilaire 1953 & 1972 - page 10

    10 IV . ANNUAL LAMP REPLACEMENT The Aprilaire Ultraviolet Germicidal Lamp is designed for the lamp to be on at all times. After 9,000 hours of operation – 1 year of constant use – the effectiveness of the lamp inside the unit diminishes and needs to be replaced. Rarely will a lamp burn out in one year of continuous use; replacement is necessary ...

  • Aprilaire 1953 & 1972 - page 11

    11 VI. TROUBLESHOOTING If the Lamp does not operate, check the following: 1. Electrical Connections – Verify that the Lamp has been wired correctly . The power to lamp must be always ‘on’ during normal operation. On External Mount Units, verify that safety switch inside the cover of Unit Base has not been damaged. The voltage into the units s ...

  • Aprilaire 1953 & 1972 - page 12

    B2203283 1015 E. W ASHINGT ON A VE. • MADISON, WI 53703 • PHONE: 888/782-8638 • F AX: 608/257-4357 • www .aprilairecontractor .com VIII. LIMITED WARRANTY Y our Research Products Corporation Aprilaire Ultraviolet Germicidal Lamp Model 1952, 1953 or 1972 is expressly warranted for th ree (3) years from the date of installation to be free from ...

Fabricante Aprilaire Categoría Humidifier

Los documentos del dispositivo Aprilaire 1953 & 1972 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Aprilaire
- manuales de instrucciones 1953 & 1972
- hojas de producto Aprilaire
- folletos informativos
- o etiquetas energéticas Aprilaire 1953 & 1972
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Aprilaire 1953 & 1972.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Aprilaire 1953 & 1972, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Aprilaire 1953 & 1972. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Aprilaire 1953 & 1972.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Aprilaire 1953 & 1972, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Aprilaire 1953 & 1972. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Aprilaire 1953 & 1972.

El manual de instrucciones completo de Aprilaire debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Aprilaire 1953 & 1972 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Aprilaire 1953 & 1972, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Aprilaire 1953 & 1972 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Aprilaire 1953 & 1972 - que deben facilitarnos los primeros pasos durante el uso de Aprilaire 1953 & 1972
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Aprilaire 1953 & 1972
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Aprilaire 1953 & 1972 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Aprilaire 1953 & 1972?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Aprilaire 1953 & 1972, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Aprilaire 1953 & 1972 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)