  • DCS -VH-30S - page 1

    THE PROFESSIONAL VENT HOODS Use and Installation Guide Models:  DCS-VH-48HS  DCS-VH-48S  DCS-VH12-36HS  DCS-VH12-36S  DCS-VH-36HS  DCS-VH-36S  DCS-VH-30HS  DCS-VH-30S Dyn a m i c C o o k i n g Sy s t e m s, In c. ...

  • DCS -VH-30S - page 2

    A M e ss a ge T o Ou r C u s t o m e r s 1 Thank you for selecting this Dynamic Cooking Systems Pr ofessional V ent Hood. Because of its unique featur es , we have developed this Use and Installation Guide. It contains valuable information on how to pr operly operate and maintain your new V ent Hood for years of safe and enjo yable cooking. T o hel ...

  • DCS -VH-30S - page 3

    T ab le O f Content s 2 INTRODUCTION: The Dynamic Cooking Systems V ent Hood Models ha ve been designed with the ultimate in household conv enience in mind. Features include High Ca pacity , V ariable Speed Blow er , Commer cial Style dishwasher -safe filters, Easy-to-Clean inside liner , and Illuminating Halogen Lighting, all packaged in a stylish ...

  • DCS -VH-30S - page 4

    S af ety P ractice s & P recaution s 3 W ARNING- T o reduce the risk of a range top grease f ire: A) Nev er leav e surface units unattended at high settings. Boilovers cause smoking and gr easy spillov ers that may ignite. Heat oil slowly on lo w or medium settings. B) Alwa ys turn hood “ON” when cooking at high heat or when cooking flaming ...

  • DCS -VH-30S - page 5

    P lanning T he I ns tallation 4 BA CKDRAFT D AMPER: W e recommend that a backdraft damper be used in all V ent Hood installations. Cold weather installa- tions necessitate the use of a backdraft damper to minimize the flow of cold air into the r oom. A non- metallic thermal break should also be installed to minimize conduction of outside temperatur ...

  • DCS -VH-30S - page 6

    V ent Hood A s s emb ly 5 A B DCS Duct Cover (6" or 12" Height) Rough-In Kit junction box junction box Hood Inner Liner (Remove) ( 48" Model Liner Shown) Through junction box on rough-in kit, connect to house wiring to blower motor control panel Model DCS-IB12 Blower DCS VH 48 DCS VH12 36 Model DCS-IB6 Blower DCS VH 36 DCS VH 30 Roug ...

  • DCS -VH-30S - page 7

    6 V ent Hood I n s tallation ( with s of f it ) SITE PREP ARA TION This DCS Pr ofessional V ent Hood has been designed to accommodate installation into a 1) soffit structure (ceiling mount), or , for sites without a soffit structure. 2) directl y into the wall through holes pr ovided in the r ear panel of the vent hood (wall mount). When mounting t ...

  • DCS -VH-30S - page 8

    7 V ent Hood I n s tallation ( with s of f it ) INST ALL VENT HOOD INT O SOFFIT At this point in the installation pr ocess, the inner liner should be remo ved fr om the Hood and set aside (see-Pgs 5 & 6). With the liner set aside, there is clear access to the Soffit mounting holes and wall mounting holes in the rear panel of the unit. Once the ...

  • DCS -VH-30S - page 9

    8 V ent Hood I n s tallation ( without s of f it ) SITE PREP ARA TION: In cases where the installation site does not ha v e a soffit structure, the V ent Hood assembly ma y be secured dir ectly to the wall fr om the rear of the unit. NO TE- When installing the vent hood directly to the rear w all, an adequate structural w all suppor t (studs) must ...

  • DCS -VH-30S - page 10

    Fi n i sh i n g Th e In s t a l l a t i o n 9 T O FINISH THE INST ALLA TION Once the ventilation hood has been mounted in place it will be necessar y to install the electrical ser vice. All electrical work should be done by a qualified electrician and must conform to all local standards. Refer to the wiring diagrams on Pgs. 14-15, for pr oper hook- ...

  • DCS -VH-30S - page 11

    D uct I nfo rmation 10 GENERAL - When planning the path for ducting to the outside, keep in mind the following guidelines: - Minimize use of elbows and transitions in ductw ork as to maximize air flow to outside of building. An efficient airflow path contributes to the ov erall efficiency of the V ent Hood. - DCS recommends the use of smooth wall d ...

  • DCS -VH-30S - page 12

    D CS VH S e r i e s Sp e c i fi c a t i o n s 11 DCS VH SERIES HOODS Specify 48",36",30" 25" 18" 12" Specify 48",36",30" 12" 6",12" 3" 7-1/4" 3/4" 10-1/4" 12-1/4" 23-1/2" 10-1/4" 10-1/4" 7" 4-1/2" 3/4" 23-1/2" 10-1/4" 18-1/4& ...

  • DCS -VH-30S - page 13

    S e rvice 12 HO W T O OBT AIN SER VICE: Befor e you call for service: 1) Is the cir cuit break er tripped or the fuse blown? 2) Is there a po wer outage in the area? For war ranty ser vice, contact your local DCS authorized service agency . Provide him with the Model Number , Serial Number , and date of installation, and a brief description of the ...

  • DCS -VH-30S - page 14

    Wa r ranty 13 LENGTH OF W ARRANTY: One (1) Y ear Full parts and Labor Covers the entir e product Five (5) Y ear Limited war ranty covering the switches and motor . DCS WILL P A Y FOR All repair labor and parts found to be defectiv e due to materials or workmanship for one full y ear “IN HOME” warranty during the first y ear of ownership. This d ...

  • DCS -VH-30S - page 15

    Wi r i n g Di a g r a m DCS VH 48 14 CONNECTORS: WN-3 zinc brass SPEED CONTROL zinc brass (N) WHT (L1) BLK (GROUND) GRN WN-2 WN-1 WHT BLK LEFT LIGHT FAN SWITCH LEFT HEAT LIGHT MOTOR PLUG BLOWER MOTOR USED ON HS MODELS ONLY LEFT HEAT LIGHT SWITCH LIGHT SWITCH RIGHT HEAT LIGHT SWITCH RIGHT LIGHT RIGHT HEAT LIGHT USED ON HS MODELS ONLY 8 1 2 3 4 5 6 F ...

  • DCS -VH-30S - page 16

    Wi r i n g Di a g r a m DCS VH 30/36 15 zinc brass SPEED CONTROL WN-2 WN-1 LEFT LIGHT FAN SWITCH HEAT LIGHT USED ON HS MODELS ONLY HEAT LIGHT SWITCH LIGHT SWITCH RIGHT LIGHT 17 1 1a 1b 18 15 1a 1b 2b 10 11 4 3 1a 1b 15 9 10 13 1 19 14 (N) WHT (L1) BLK (GROUND) GRN 8 JUNCTION BOX 6 WN-3 2 CONNECTORS: 1 2 3 4 5 6 FEMALE 1 2 3 4 5 6 MALE BLOWER MOTOR ...

  • DCS -VH-30S - page 17

    No t e s 16 ...

  • DCS -VH-30S - page 18

    Part No. 10607r4 Litho in USA 04/2001 As product impr ovement is an ong o- ing process at DCS, we reserve the right to change specifications or design without notice. 5800 Skylab Road, Huntington Beach, C A 92647 T el: (714) 372-7000 Fax: (714) 372-7001 Par ts/Customer Service (888) 281-5698 www .dcsappliances.com ...

Fabricante DCS Categoría Ventilation Hood

Los documentos del dispositivo DCS -VH-30S que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos DCS
- manuales de instrucciones -VH-30S
- hojas de producto DCS
- folletos informativos
- o etiquetas energéticas DCS -VH-30S
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones DCS -VH-30S.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje DCS -VH-30S, instrucciones de servicio, instrucciones cortas o instrucciones de usuario DCS -VH-30S. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto DCS -VH-30S.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo DCS -VH-30S, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar DCS -VH-30S. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de DCS -VH-30S.

El manual de instrucciones completo de DCS debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual DCS -VH-30S - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice DCS -VH-30S, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de DCS -VH-30S que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo DCS -VH-30S - que deben facilitarnos los primeros pasos durante el uso de DCS -VH-30S
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con DCS -VH-30S
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de DCS -VH-30S en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de DCS -VH-30S?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con DCS -VH-30S, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con DCS -VH-30S probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)