Manual de instrucciones Lincoln Electric SAE-400 SEVERE DUTY IM727

33 de páginas 0.47 mb
Descargar

Pasar a la página of 33

Summary
  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 1

    OPERA T OR’S MANUAL S AE-400 SEVERE DUTY DC ARC WELDING PO WER SOURCE IM727 January , 2005 For use with machines having Code Number: 10856 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by pr oper installation ... and thoughtful opera- tion ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 2

    FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. _______________________________________________ ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 4

    iii SAFETY iii FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’s recommendations. 8.c. Ground the equipment in accordance with the U.S. Nati ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 5

    iv SAFETY iv Mar . ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ’Arc 1. Protegez-vous contre la secousse électrique: a. L ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 7

    vi T ABLE OF CONTENTS SAE-400 SEVERE DUTY vi Page Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section A T echnical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1 Installation Precautions . . . . . . . . . . . . . ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 8

    A-1 INST ALLA TION SAE-400 SEVERE DUTY A-1 TECHNICAL SPECIFICA TIONS - SAE-400 SEVERE DUTY Make/Model Description Speed (RPM) Displacement Starting Capacities System Perkins 4 cylinder High Idle 1800 256 cu. in 12VDC batteries Fuel: 22.5 gal. 1004.42 Diesel 71 HP @ Low Idle 1 100 (4.2 L) (2 ) & Starter 85.1 L Engine 1725 RPM Full Load 1725 Bore ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 9

    A-2 INST ALLA TION SAE-400 SEVERE DUTY A-2 Read this entire installation section before you start installation. SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly read all operating and maintenance man- uals supplied with your machine. They include impor- tant safety precautions, detailed engine starting, operating an ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 10

    A-3 INST ALLA TION SAE-400 SEVERE DUTY A-3 HIGH AL TITUDE OPERA TION At higher altitudes, output derating may be necessary . As a rule of thumb, derate the welder output 5% for every 500 meters (1640 ft.) above 1000 meters (3280 ft.). Contact a Perkins Service Representative for any engine adjustments that may be required for high alti- tude operat ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 11

    A-4 INST ALLA TION A-4 SAE-400 SEVERE DUTY BA TTER Y CONNECTION W ARNING: Use caution as the electrolyte is a strong acid that can burn skin and damage eyes. Remove and discard the insulating caps from the neg- ative battery terminals. Attach and tighten negative battery cable terminals. NOTE: This machine is furnished with wet charged batteries; i ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 12

    A-5 INST ALLA TION SAE-400 SEVERE DUTY A-5 WELDING OUTPUT CABLES With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if neces- sary . Listed in T able A.1 are copper cable sizes recom- mended for the rated current and duty cycle. Lengths stipulated are the ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 13

    B-1 OPERA TION B-1 WELDING SP ARKS can cause fire or explosion. • Do not weld near flammable material . • Do not weld on containers that have held flammable material. ----------------------------------------------------------- MOVING P ARTS can injure. • Keep away from moving parts • Do not operate with doors open or guards off. • Stop en ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 14

    B-2 OPERA TION B-2 DESIGN FEA TURES AND ADV ANT AGES FOR STICK WELDING • Excellent DC constant current output for stick weld- ing applications. • Continuous adjustment of both voltage and current for unsurpassed welds on demanding jobs. • Remote control capability standard. FOR AUXILIAR Y POWER • 3,000 watts of 1 15/230 V AC, 60 Hz auxiliar ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 15

    B-3 OPERA TION B-3 ENGINE CONTROLS IGNITION SWITCH When placed in the “ ON ” position, this switch ener- gizes the fuel solenoid. When placed in the “ OFF ” posi- tion, the flow of fuel to the injection pump is stopped to shut down the engine. “IDLER” SWITCH The idler switch has two positions, “ HIGH ” and “ AUTO ” . When in “ ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 16

    B-4 OPERA TION B-4 WELDER CONTROLS POLARITY SWITCH T urn the Arc Polarity switch to electrode positive or electrode negative as required for each particular application. CONTROL OF WELDING CURRENT Purpose of Controls The continuous “ Current Control ” is the main current adjuster . The “ Job Selector ” is both a fine current adjuster and th ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 17

    B-5 OPERA TION B-5 ENGINE OPERA TION Do not adjust the high idle engine speed (rpm) above the factory setting specification. ------------------------------------------------------------------------ ST ARTING INSTRUCTIONS Be sure all Pre-Operation Maintenance has been per- formed. (See INST ALLA TION section of this manual). T o start the engine, pl ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 18

    C-1 ACCESSORIES C-1 OPTIONAL FIELD INST ALLED ACCESSORIES K802-D Power Plug Kit - Kit includes male plugs for each auxiliary receptacle. K767-1 T railer - A 4-wheel steerable trailer for in-plant and yard towing (1) with E78-14 load range (B) tubeless tires. Mounts directly to welder base. K956-1 and -2 T railer - A 2-wheel trailer designed for roa ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 19

    D-1 MAINTENANCE D-1 ELECTRIC SHOCK can kill. ● Do not touch electrically live parts such as output terminals or inter- nal wiring ENGINE EXHAUST can kill. ● Use in open, well ventilated areas or vent exhaust outside MOVING P ARTS can injure. ● Do not operate with doors open or guards off ● Stop engine before servicing ● Keep away from mov ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 20

    D-2 MAINTENANCE D-2 BEARING MAINTENANCE This welder is equipped with a double-shielded ball bearing having sufficient grease to last indefinitely under normal ser- vice. Where the welder is used constantly or in excessively dirty locations, it may be necessary to add one-half ounce of grease per year . A pad of grease one inch wide, one inch long a ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 21

    D-3 MAINTENANCE D-3 1. Close the fuel shutoff valve located on the fuel strainer mounted to the under side of the fuel tank. 2. Unscrew the cap ring located on the top of the filter header and remove the plastic center cap and O- ring. 3. Remove the large white volume plug located direct- ly under the center cap in the upper cavity of the fil- ter ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 22

    D-4 MAINTENANCE D-4 SP ARK ARRESTOR For machines with separate spark arresting unit: Service the spark arrestor every 100 hours of opera- tion or twice a year , which ever occurs first. Service as follows: 1. Stop engine and allow to cool. 2. Loosen clamp and remove spark arrestor from machine. 3. Remove locknut on top of spark arrestor housing and ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 23

    E-1 TROUBLESHOOTING E-1 SAE-400 SEVERE DUTY If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION W ARNING ELECTRIC SHOCK can kill. • Do not touch electrically ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 24

    E-2 TROUBLESHOOTING E-2 SAE-400 SEVERE DUTY Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PR ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 25

    E-3 TROUBLESHOOTING E-3 SAE-400 SEVERE DUTY Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PR ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 26

    E-4 TROUBLESHOOTING E-4 SAE-400 SEVERE DUTY Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely , contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PR ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 27

    F-1 WIRING DIAGRAMS SAE-400 SEVERE DUTY F-1 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. SWITCH PROTECT I ON P.C. BOA RD IDL ER/E NGINE J1 + S W ITCH (N.C. ) OI L PR ES SUR E THER MOST ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 28

    SAE-400 SEVERE DUTY F-2 WIRING DIAGRAMS F-2 NOTE: This diagram is for reference only . It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. 7- 2 001G M192 37 COLOR CODE ALT ERNA TOR ROT OR AC + SLI P - RINGS (-) D2 FLA SHING D IODE B-B ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 29

    SAE-400 SEVERE DUTY F-3 DIMENSION PRINT F-3 M8869-23 5/01 28.0 0 24.5 0 27.1 2 22.0 0 22.1 4 6.00 39.69 50.13 8.90 69.7 5 77.00 81.25 83.0 0 38.5 0 63.06 .88 3.00 8.12 6.31 26.75 CENTER OF GRAVITY WITH OIL AND WATER IN ENGINE, BUT NO FUEL N.A. .81 DIA. HOLES. N.B. .6 9 DI A. HOLES. N.A. N.A. N.B. N.B. 43.7 5 44.50 23.13 ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 30

    SAE-400 SEVER DUTY NOTES ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 31

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA EL ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 32

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes f ...

  • Lincoln Electric SAE-400 SEVERE DUTY IM727 - page 33

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 441 17-1 199 U.S.A. TEL: 216.481.8100 F AX: 216.486.1751 WEB SITE: www .lincolnelectric.com • World's Leader in W elding and Cutting Products • ...

Fabricante Lincoln Electric Categoría Welding System

Los documentos del dispositivo Lincoln Electric SAE-400 SEVERE DUTY IM727 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Lincoln Electric
- manuales de instrucciones SAE-400 SEVERE DUTY IM727
- hojas de producto Lincoln Electric
- folletos informativos
- o etiquetas energéticas Lincoln Electric SAE-400 SEVERE DUTY IM727
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Lincoln Electric SAE-400 SEVERE DUTY IM727.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Lincoln Electric SAE-400 SEVERE DUTY IM727, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Lincoln Electric SAE-400 SEVERE DUTY IM727. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Lincoln Electric SAE-400 SEVERE DUTY IM727.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Lincoln Electric SAE-400 SEVERE DUTY IM727, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Lincoln Electric SAE-400 SEVERE DUTY IM727. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Lincoln Electric SAE-400 SEVERE DUTY IM727.

El manual de instrucciones completo de Lincoln Electric debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Lincoln Electric SAE-400 SEVERE DUTY IM727 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Lincoln Electric SAE-400 SEVERE DUTY IM727, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Lincoln Electric SAE-400 SEVERE DUTY IM727 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Lincoln Electric SAE-400 SEVERE DUTY IM727 - que deben facilitarnos los primeros pasos durante el uso de Lincoln Electric SAE-400 SEVERE DUTY IM727
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Lincoln Electric SAE-400 SEVERE DUTY IM727
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Lincoln Electric SAE-400 SEVERE DUTY IM727 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Lincoln Electric SAE-400 SEVERE DUTY IM727?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Lincoln Electric SAE-400 SEVERE DUTY IM727, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Lincoln Electric SAE-400 SEVERE DUTY IM727 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)