Manual de instrucciones Master Lock 70000 BTU/Hr

24 de páginas 0.41 mb
Descargar

Pasar a la página of 24

Summary
  • Master Lock 70000 BTU/Hr - page 1

    Heater Sizes: 70,000 100,000 150,000 BTU/Hr IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. 100 SIDE PV 002 PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL R 150 SIDE HANDLE PFA/PV 005 ...

  • Master Lock 70000 BTU/Hr - page 2

    2 101585 Safety Information ......................................................................... 3 Product Identification .................................................................... 4 Unpacking ...................................................................................... 5 Assembly ........................................... ...

  • Master Lock 70000 BTU/Hr - page 3

    3 101585 SAFETY INFORMA TION ! DANGER Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the fl u, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected b ...

  • Master Lock 70000 BTU/Hr - page 4

    4 101585 Upper Shell Figure 3 - 150,000 BTU/Hr Model 35/50/70,000 BTU/HR DOMESTIC PFA/PV 042 Handle Fuel Cap Lower Shell Side Cover Fuel Tank Figure 1 - 70,000 BTU/Hr Model Side Cover Fuel Tank Lower Shell Fuel Cap Fan Guard Power Cord Upper Shell PRODUCT IDENTIFICA TION Upper Shell Hot Air Outlet Hot Air Outlet Air Filter End Cover Fan Guard Power ...

  • Master Lock 70000 BTU/Hr - page 5

    5 101585 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y (For 100,000 and 150,000 BTU/Hr Models Only) These models are furnished with wheels and handles. Wheels, handles, and ...

  • Master Lock 70000 BTU/Hr - page 6

    6 101585 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fi ne mist of fuel is sprayed into the combustion chamber. The Air System: The motor turns the fan. The fan pushes air into and around the combustion cham ...

  • Master Lock 70000 BTU/Hr - page 7

    7 101585 VENTILA TION OPERA TION Continued Figure 6 - Flame-Out Control Reset Button, 70,000 BTU/Hr Model Figure 7 - Flame-Out Control Reset Button, 100/150,000 BTU/Hr Models W ARNING Follow the minimum fresh, outside air ventilation requirements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide ...

  • Master Lock 70000 BTU/Hr - page 8

    8 101585 OPERA TION Continued To Stop Heater 1. Unplug power cord from outlet. To Restart Heater 1. Wait 2 minutes after stopping heater. 2. Repeat steps under To Start Heater , page 7. 1. Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, dra ...

  • Master Lock 70000 BTU/Hr - page 9

    9 101585 TROUBLE- SHOOTING OBSERVED FAULT POSSIBLE CAUSE REMEDY Wrong pump pressure Dirty air output, air intake, and lint fi lters Dirty fuel fi lter Dirt in nozzle Dirty photocell lens Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time See Pump Pressure Adjustment , page 12. See Air Output, ...

  • Master Lock 70000 BTU/Hr - page 10

    10 101585 SER VICE PROCEDURES Upper Shell Removal 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. 2. Lift upper shell off. 3. Remove fan guard. Figure 10 - Fuel Filter Removal, 70,000 BTU/Hr Model Fuel Filter Side Cover Fuel Line Fuel Filter (70,000 BTU/Hr Model) 1. Remove ...

  • Master Lock 70000 BTU/Hr - page 11

    11 101585 150,000 BTU/Hr PFA/P 041.G Fuel Filter (100/150,000 BTU/Hr Models) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel fi lter neck. 4. Carefully pry bushing, lower fuel line, and fuel fi lter out of fuel tank. 5. Wash fuel fi lter with clean fuel and replace in tank. 6. Attac ...

  • Master Lock 70000 BTU/Hr - page 12

    12 101585 Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover. 4. Replace air output and lint fi lters. 5. Wash or replace air intake fi lter (see Preventative Maintenance Schedule, page 8). 6. Replace fi lter end cover. 7. Re ...

  • Master Lock 70000 BTU/Hr - page 13

    13 101585 Nozzle 1. Remove upper shell (see page 10). 2. Remove fan (see page 15). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6. Remove three screws using 5/16" nut-driver and remove burner head from combustion chamber. ...

  • Master Lock 70000 BTU/Hr - page 14

    14 101585 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove fi lter end cover screws using 5/16" nut- driver. 3. Remove fi lter end cover and air fi lters. 4. Remove pump plate screws using 5/16" nut- driver. 5. Remove pump plate. 6. Remove rotor, insert, and blades. 7. Check for debris in pump. ...

  • Master Lock 70000 BTU/Hr - page 15

    15 101585 Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 10). 2. Use 1/8" allen wrench to loosen setscrew which holds fan to motor shaft. 3. Slip fan off motor shaft. 4. Clean fan using a soft cloth moistened wi ...

  • Master Lock 70000 BTU/Hr - page 16

    16 101585 ILLUSTRA TED P ARTS BREAKDOWN 70,000 BTU/Hr 18-2 Motor and Pump Assembly 18-5 18-16 18-4 18-8 18-3 18-6 18-7 18-9 18-10 18-11 18-12 18-13 18-14 18-15 10-2 10-3 10-4 10-5 10-6 10-7 10-1 18-1 18-18 Burner Head Assembly 1 2 4 3 5 6 7 8 10 11 12 12 14 15 16 17 20 18 19 21 22 24 25 26 27 28 29 30 31 32 34 38 37 41 13 9 33 35 36 42 43 39 40 23 ...

  • Master Lock 70000 BTU/Hr - page 17

    17 101585 P ARTS LIST 70,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-54 Upper Shell 1 3 100647 ...

  • Master Lock 70000 BTU/Hr - page 18

    18 101585 ILLUSTRA TED P ARTS BREAKDOWN 100,000 BTU/Hr 13-1 13-2 13-3 13-4 13-5 13-7 13-8 13-9 13-10 13-11 13-12 13-13 13-15 13-16 13-17 13-18 13-14 Motor and Pump Assembly BURNER HEAD 100 EAI/EBI PFA/P 022 8-2 8-6 8-5 8-4 8-3 8-1 Burner Head Assembly 8-7 13-6 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 25 29 30 31 32 33 34 35 36 37 38 39 40 4 ...

  • Master Lock 70000 BTU/Hr - page 19

    19 101585 P ARTS LIST 100,000 BTU/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. **Not available as an assembly, order parts separately. KEY PART PART NO. NUMBER DESCRIPTION QTY ...

  • Master Lock 70000 BTU/Hr - page 20

    20 101585 ILLUSTRA TED P ARTS BREAKDOWN 150,000 BTU/Hr 10-2 10-11 Motor and Pump Assembly 10-1 10-4 10-3 10-5 10-6 10-7 10-8 10-9 10-10 10-12 10-13 10-14 10-15 10-16 10-17 10-18 BURNER HEAD 100 EAI/EBI PFA/P 022 Burner Head Assembly 7-1 7-2 7-3 7-4 7-5 7-7 7-6 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 25 26 27 24 28 29 20 22 21 30 31 41 33 34 35 36 13 ...

  • Master Lock 70000 BTU/Hr - page 21

    21 101585 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST 150,000 BTU/Hr 1 098511-138 Upper Shell 1 2 100647-01 Screw, #10-16 x 1/2" 8 3 098512-29 Combustion Chambe ...

  • Master Lock 70000 BTU/Hr - page 22

    22 101585 4 7 KEY PART PART 100,000 150,000 NO. NUMBER DESCRIPTION QTY. QTY. 1 HA2203 Handles 2 — HA2204 Handles — 2 2 M12345-33 Screw, #10-24 x 1 3/4" 8 8 3 M12342-3 Wheel Support Frame 1 — M12831-3 Wheel Support Frame — 1 4 NTC-3C Hex Nut, #10-24 8 8 5 097896-01 Wheel 2 2 6 M28526 Cap Nut 2 2 7 M51015-01 Axle 1 — M16801-2 Axle — ...

  • Master Lock 70000 BTU/Hr - page 23

    23 101585 WIRING DIAGRAMS Figure 26 - Wiring Diagram ACCESSORIES Purchase accessories from your local dealer. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. For 70,000 BTU/Hr model only. AIR GAUGE KIT - HA1180 For all models. Special tool to check pump pressure. Ignitor Wh ...

  • Master Lock 70000 BTU/Hr - page 24

    W ARRANTY AND REP AIR SER VICE POSE. IN ANY EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PAR- TICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. Any transportation charges, costs of installation, duty, taxes or any other charges whatsoever must be borne by the user. DESA International's oblig ...

Fabricante Master Lock Categoría Electric Heater

Los documentos del dispositivo Master Lock 70000 BTU/Hr que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Master Lock
- manuales de instrucciones 70000 BTU/Hr
- hojas de producto Master Lock
- folletos informativos
- o etiquetas energéticas Master Lock 70000 BTU/Hr
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Master Lock 70000 BTU/Hr.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Master Lock 70000 BTU/Hr, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Master Lock 70000 BTU/Hr. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Master Lock 70000 BTU/Hr.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Master Lock 70000 BTU/Hr, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Master Lock 70000 BTU/Hr. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Master Lock 70000 BTU/Hr.

El manual de instrucciones completo de Master Lock debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Master Lock 70000 BTU/Hr - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Master Lock 70000 BTU/Hr, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Master Lock 70000 BTU/Hr que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Master Lock 70000 BTU/Hr - que deben facilitarnos los primeros pasos durante el uso de Master Lock 70000 BTU/Hr
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Master Lock 70000 BTU/Hr
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Master Lock 70000 BTU/Hr en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Master Lock 70000 BTU/Hr?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Master Lock 70000 BTU/Hr, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Master Lock 70000 BTU/Hr probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)