Manual de instrucciones York 13 AND 14 SEER

12 de páginas 0.26 mb
Descargar

Pasar a la página of 12

Summary
  • York 13 AND 14 SEER - page 1

    OUTDOOR SPLIT -SYSTEM AIR CONDITIONER MODELS: 10, 1 2, 13 AND 14 SEER 1 PHASE - 1.5 TO 5 T O NS 035-13606-003 Rev. A (202) T ABLE OF CONTENTS GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . 2 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 L ...

  • York 13 AND 14 SEER - page 2

    035-13606-003 Rev. A (202) 2 Unitary Products Group GENERAL INFORMA TION These outdoor units are designed to be connected to a matching UPG indoor coil with sweat connection lines. The se units are factory charged with refrigerant for a matching indoor coil plus 15 feet of fie ld supplied line. The outside unit is designed to be placed alongside or ...

  • York 13 AND 14 SEER - page 3

    035-13606-003 Rev. A (202) Unitary Products Group 3 A minimum clearance of 18 inches is required for service at the control panel and compre ssor compartments access. A 10 inch clearance is required for the air inlet to the outdoor coil around the pe rimeter of the uni t. The air discharg e of the unit requires a 60 inch clearance betwe en the top ...

  • York 13 AND 14 SEER - page 4

    035-13606-003 Rev. A (202) 4 Unitary Products Group INST ALLA TION OUTDOOR U NIT After the site has been select ed, a solid base pad that will not shift or settle should be provided. Th e base pad should not come in contact with the foundat ion or side of the structur e because sound may be tran smitted to the residence. The pad should be located f ...

  • York 13 AND 14 SEER - page 5

    035-13606-003 Rev. A (202) Unitary Products Group 5 RE-ASSEMBLING , BRAZING AND CLEANING OF JOINT CONNECTIONS Remove the Schrader V alv e cores from the service valves. Remove the plugs from the service valve fiel d tubing connec- tions. Clean the jo ints to be brazed. NOTE: Do not overheat the connection to be brazed as this can cause improper flo ...

  • York 13 AND 14 SEER - page 6

    035-13606-003 Rev. A (202) 6 Unitary Products Group REFRIGERANT V AL VE OPERA TION All models in this series have brass service va lves. These valves are not back seating. Opening or closing valve does not close service port. Service ports have Schrader valves for gauge connections. Use back-up wre nch on valve body when removing cap to open o r cl ...

  • York 13 AND 14 SEER - page 7

    035-13606-003 Rev. A (202) Unitary Products Group 7 LOW VOL T AGE Control wiring may vary depending upon the type of thermo- stat and furnace being connected. Low voltage wiring diagrams can be found with the furnace or air conditioning blower package installation instructions. Pig-tail connector wires (2 blue or 1 blue, 1 brown) are pro- vided fro ...

  • York 13 AND 14 SEER - page 8

    035-13606-003 Rev. A (202) 8 Unitary Products Group E SYSTEM CHARGE The factory charge in the outdoor unit includes enough charge for the unit a nd a most sold matched evaporator . Some indoor coil matches may requi re some additional charge. See T abular Data sheet provided in unit literature packet. Sweat connect units also include sufficient cha ...

  • York 13 AND 14 SEER - page 9

    035-13606-003 Rev. A (202) Unitary Products Group 9 T able 3: SUPERHEA T V ALUE INDOOR WB ° F 1 OUTDOOR DB ° F 55 60 65 70 75 80 85 90 95 100 105 1 10 1 15 50 9 7 52 12 10 6 54 14 12 10 7 56 17 15 14 10 6 58 20 18 16 13 9 5 60 23 21 19 16 12 8 6 62 26 24 22 19 16 12 8 5 64 29 27 24 21 18 15 1 1 9 6 66 32 31 30 24 23 18 15 1 1 9 6 68 35 33 30 27 2 ...

  • York 13 AND 14 SEER - page 10

    035-13606-003 Rev. A (202) 10 Unitary Products Group 3. Measure and record the suction pressure at the su ction service valve port. 4. Using T a ble 4, note the superheat value corresponding to the intersecti on of the indoor wet b ulb and the outdoor dry bulb. 5. With the superheat value o btained in step 4 and the suc- tion pressure value from st ...

  • York 13 AND 14 SEER - page 11

    035-13606-003 Rev. A (202) Unitary Products Group 11 SER VICE RECORDS ...

  • York 13 AND 14 SEER - page 12

    Subject to change without notice. Printe d in U.S.A. 035-13606-003 Rev. A (202) Copyright © by Y ork International Corp. 2002. All rights reserved. Supersedes: 035-13606-002, 550.46-N1Y (199) Unitary 5005 Norman Product s Y ork OK Group Drive 73069 ...

Fabricante York Categoría Air Conditioner

Los documentos del dispositivo York 13 AND 14 SEER que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos York
- manuales de instrucciones 13 AND 14 SEER
- hojas de producto York
- folletos informativos
- o etiquetas energéticas York 13 AND 14 SEER
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones York 13 AND 14 SEER.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje York 13 AND 14 SEER, instrucciones de servicio, instrucciones cortas o instrucciones de usuario York 13 AND 14 SEER. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto York 13 AND 14 SEER.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo York 13 AND 14 SEER, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar York 13 AND 14 SEER. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de York 13 AND 14 SEER.

El manual de instrucciones completo de York debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual York 13 AND 14 SEER - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice York 13 AND 14 SEER, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de York 13 AND 14 SEER que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo York 13 AND 14 SEER - que deben facilitarnos los primeros pasos durante el uso de York 13 AND 14 SEER
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con York 13 AND 14 SEER
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de York 13 AND 14 SEER en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de York 13 AND 14 SEER?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con York 13 AND 14 SEER, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con York 13 AND 14 SEER probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)