    PV500 - 17 05 - 2000 Section 17 1 INSTALLATION & MAINTENANCE MANUAL FOR MAXIM INTEGRATED WATER HEATING SYSTEM TABLE OF CONTENTS Start - up Procedures 2 Maintenance & Safety Inspections 3 - 5 Wiring Diagrams 6,7 Burner 8 Burner Start - up 9 - 12 Burner Troubleshooting 13.14 MXG Burner Manua l Refer to PV500 - 21A MXO Burner Manual Refer to P ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 2

    PV500 - 17 05 - 2000 Section 17 2 START - UP PROCEDURES CAUTION: DO NOT RELIGHT PILOT OR START BURNER WITH COMBUSTION CHAMBER FULL OF GAS OR OI L VAPOR, OR WITH VERY HOT COMBUSTION CHAMBER. 1. Study the burner start - up information included in this manual carefully. 2. Fill the water heater tank with water. Open the relief valve or a nearby hot wa ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 3

    PV500 - 17 05 - 2000 Section 17 3 MAXIM MAINTENANCE AND SAFETY INSPECTIONS 1. Establ ish a preventive maintenance program to assure a longer water heater life. 2. The tank should be flushed at two - or three - month intervals depending on water conditions in your location. To flush, turn off electrical disconnect switch to prevent the burner fr om ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 4

    PV500 - 17 05 - 2000 Section 17 4 MAXIM MAINTENANCE AND SAFETY INSPECTIONS (continued) Periodic Inspection of Operation Components (continued) CAUTION: THE RELIEF VA LVE IS A PRIMARY SAFETY DEVICE. 2. The temperature and pressure relief valve may be checked by slowly lifting the seat lever on top of the valve to determine its condition for safe ope ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 5

    PV500 - 17 05 - 2000 Section 17 5 MAINTENANCE & SAFETY INSPECTION REPORT DATE BURNER INSPECTION COMBUSTION ANALYSIS TANK INSPECTION TANK FLUSH & CLEANOUT TANK FITTING INSPECTION VENT INSPECTION THERMOSTAT INSPECTION GAS TRAIN LEAK TEST Recommended Inspection Intervals YEARLY 6 MONTHS 6 MONTHS 3 MONTHS 6 MONTHS YEARLY YEARLY YEARLY TABLE 17 ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 6

    PV500 - 17 05 - 2000 Section 17 6 MAXIM AXIAL FLOW GAS BURNER CARBON MONOXIDE WARNING: CAUTION: IMPROPER COMBUSTION MAY CAUSE SERIOUS INJURY. PVI recommends a s easonal or annual combustion check - out be performed by a qualified service agency to ensure safe and efficient operation. TYPICAL CONSTRUCTION FIGURE 17 - 2 1. FAN HOUSING 9. AIR PROVING ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 7

    PV500 - 17 05 - 2000 Section 17 7 MAXIM AXIAL FLOW GAS BURNER START - UP (Refer to Figure 17 - 2, page 6 to identify burner parts) 1. Remove the enclosure panel cover on the water heater or boiler to expose the control circuit. A wiring diagram, included in this packet, will show the controls used in our circuitry. 2. Visually check that all compon ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 8

    PV500 - 17 05 - 2000 Section 17 8 MAXIM AXIAL FLOW GAS BURNER START - UP (continued) PRESSURE PLATE Set up and Tolerances Figure 17 - 3 13. Connect a test meter to the control for reading the flame response signal. NOTE: Some controls read the flame signal in micro amps and some in volts DC. The TFM or MC120 series control has two terminals marked ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 9

    PV500 - 17 05 - 2000 Section 17 9 MAXIM AXIAL FLOW GAS BURNER START - UP (continued) This section pertains to MC120 control only. When the blower motor starts, the air proving light on the MC - 120 should be on. This indicates a positive air flow condition. If the air proving light is not on, turn air proving switch adjustment screw counter - clock ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 10

    PV500 - 17 05 - 2000 Section 17 10 MAXIM AXIAL FLOW GAS BURNER START - UP (continued) 17. Check flue gases with a flue analyzer to make final settings of the air shutter. a. The readings need to be taken from a hole in the vent several inches above the heater vent connection, but before draft regulator. b. Insert draft gauge into the 1/4" test ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 11

    PV500 - 17 05 - 2000 Section 17 11 MAXIM TROUBLESHOOTING SUGGESTIONS AXIAL FLOW GAS BURNER 1. BURNER FAILS TO START Defective On/Off switch. Replace switch. A. Control circuit has an open control contact. Check limits, low water cutoff, proof of closure switch and others as applicable. B. Bad fuse or switch open on incoming power source. Correct as ...

  • PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - page 12

    PV500 - 17 05 - 2000 Section 17 12 MAXIM TROUBLESHOOTING SUGGESTIONS AXIAL FLOW GAS BURNER (continued) C. Defective automatic main or auxiliary gas shut off valves. Check electrical circuitry to valves. Replace valves or correct circuitry a s required. D. Main diaphragm shut off valve opening too slowly. Adjust bleed on valve. E. Defective flame sa ...

Fabricante PVI Industries Categoría Water Heater

Los documentos del dispositivo PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos PVI Industries
- manuales de instrucciones MAXIM INTEGRATED WATER HEATING SYSTEM
- hojas de producto PVI Industries
- folletos informativos
- o etiquetas energéticas PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM, instrucciones de servicio, instrucciones cortas o instrucciones de usuario PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM.

El manual de instrucciones completo de PVI Industries debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM - que deben facilitarnos los primeros pasos durante el uso de PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con PVI Industries MAXIM INTEGRATED WATER HEATING SYSTEM probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)