    T rapeze C TP-E 4 8SX C TP-E54SX C TP-E 6 0SX Model number: Serial number: U s e , C a r e , a n d I n s ta l la tion G u id e MAY07.0101 © Zep h yr Corpo ration. ww w .zephyronline.com Date of Purchase: Sales Dealer: ...

  • Zephyr CTP-E 60SX - page 2

    www .zephyronline.com ...

  • Zephyr CTP-E 60SX - page 3

    T able of Contents 1 SAFET Y NO TICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .................................................................. Specifi ...

  • Zephyr CTP-E 60SX - page 4

    www .zephyronline.com Im p or tan t s afety N o t i c e 2 TO R ED U C E T H E R I S K O F F I R E O R E L E C TR IC SH OC K, D O N O T USE T H IS FAN W ITH ANY S O L I D-S T ATE SP E E D CONTRO L DE V I C E . TO R E DUC E T H E R I S K O F F I R E, E L E C T R IC SH O C K, O R I NJ U R Y TO P E R S ON S, O B S E RVE T H E F O L LO W I N G: a. Use t ...

  • Zephyr CTP-E 60SX - page 5

    Li s t o f M a t e r ia l s 3 MODEL: CTP-ExxS 1 - Hood 2 - Bae Filters 4 - G U-10, 120V 50 W , halogen bulbs 2 - Utensil Rails 2 - T elescopic Duct Covers 4 - T elescopic Rods Sets 4 - Angle Bra c kets (27 3/8”) 4 - Angle Bra c kets (35 3/8”) 1 - Ceiling Mounting Bra c ket 1 - Internal Flange 1 - Motor Housing 1 - HARDWARE PACKET 4 - Coupler ...

  • Zephyr CTP-E 60SX - page 6

    www .zephyronline.com 4 I n s t a lla t io n - Duct wo rk C a lcula t io n S h e e t Duct pieces To t a l Equivalent number length x used = 31 / 4 ”x1 0 ” Rect., straight 1 F t . x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 90 0 elbow 15 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 31 / 4 ...

  • Zephyr CTP-E 60SX - page 7

    5 I n s ta lla tion - M o unt i ng H e i ght & C l e a ra nc e DUC T I N G 9" 36" Min 98"-Max 124” Min 28"-Max 36" Min 34"-Max 52" Minimum mount height between range top to hood b ot- tom should be no less than 28". Maximum mount height should be no higher than 36". It is important to install the h ...

  • Zephyr CTP-E 60SX - page 8

    www .zephyronline.com 6 I n s t a lla t io n - Du ct ing WARNING FIRE HAZARD N EV E R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside. Use single wall rigid Metal ductwork onl y . F asten all connections with sheet metal screws and tape all joints w/ ce ...

  • Zephyr CTP-E 60SX - page 9

    15 3/4” 9“ “ 6 “ 9 ” 2 5 x a M - “ 4 3 n i M 26 5/8” 32” 48” , 54” , 59 1/8” Min 21” - Max 40” 12 1/8” 7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 2” 2” 7/64” 13/32” 32“ “ 9 ” 6 1 / 7 0 1 ” 2 / 1 9 9“ ” 8 / 1 4 R ” 2 3 / 5 1 ” 8 / 3 1 ” 4 6 / 1 2 0 1 O 10“ 11 3/4“ ...

  • Zephyr CTP-E 60SX - page 10

    www .zephyronline.com I n s t a lla t io n - In t er n a l B l ow er 8 The internal blower kit consists of the blower and capacitor box with wiring. A TTE NTI O N The following are intructions for installing internal blower model CB I-600. F or instructions on preparing for external blower model CB E-1000 please turn to page “10” . Before insta ...

  • Zephyr CTP-E 60SX - page 11

    I n s t a lla t io n - In t er n a l B l ow er 9 6. Attach junction box to internal ange using provided 1/2” self tapping screws and 4mm internal diameter washers. 7 . Att ac h grounding wires from junction box and motor to grounding screw as shown. 8. Place blower with attached ange into motor housing as shown on Fig-A. 9. Attach using 1/2 ...

  • Zephyr CTP-E 60SX - page 12

    www .zephyronline.com 10 I n s t a lla t io n - P re p a rin g H o o d fo r E xt e rn a l B lo we r The external blower kit consists of an 8” collar , external ange and external blower wiring box. T he external blower is purchased separately. A TTE NTI O N The following are instructions on preparing your hood for installation with e xternal bl ...

  • Zephyr CTP-E 60SX - page 13

    11 In s ta l l at i o n - M o unt i ng t he H o o d All Electrical work must by performed by qualied electrician or person with similar technical know how and bac kgr ound. F or personal saf ety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow Nationa ...

  • Zephyr CTP-E 60SX - page 14

    12 I n s t a lla t io n - M o u n ti n g th e H o o d 1. Mount motor housing to the range hood b ody using (10) 1/2” self tapping screws. 2. Determine height of hood, measure and select either 27 3/8” or 35 3/8” angle brac kets and attach (4) of them to the motor housing using (8) 1/2” self tapping screws (2) for each angle brac ket. 3. Sli ...

  • Zephyr CTP-E 60SX - page 15

    13 I n s t a lla t io n - M o u n ti n g th e H o o d 5. Lift assembled unit and atta ch all (4) angle bra ckets to ceiling bra cket. Make sure the tabs on eac h angle bra ckets are facing the outside. T he angle brackets will t between the slots on the ceiling bra cket. One half of the angle bra cket will be on the outside of the ceiling bra ck ...

  • Zephyr CTP-E 60SX - page 16

    I n s t a lla t io n - M o u n ti n g th e H o o d 14 Utensil Rail Installation 1. A ttach utensil rail to long side of hood canopy . A small hole has been pre-drilled into the canopy to provide a starting point to attach the rst utensil rail post. A fter the rst post is line up with the hole, gently slide the rest of the rail onto canopy . ( ...

  • Zephyr CTP-E 60SX - page 17

    18 F ea t u r e s & C on t r ol s - T ou c h C on t r ol s & F e a t u r es The standard Bae Filters are required to be cleaned frequently and as recommended in order to maintain blower eciency . If improperly maintained, residue from cooking will sift though lters and cause damage to hood blo wers and other sensitive components; a ...

  • Zephyr CTP-E 60SX - page 18

    16 Filter Clean Reminder (Standard Bae Filters tted): A set of bae lters are tted by the factory . These Bae Filters are intended to lter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in the microprocessor will automatically indicate ...

  • Zephyr CTP-E 60SX - page 19

    www .zephyronline.com 17 M a int e n a nce - C le aning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. F or heavier soil use liquid degreaser . After cleaning, you may use non-abrasive stainless steel ...

  • Zephyr CTP-E 60SX - page 20

    18 Ma i n t e n an c e - Lights R eplacing Light Bulbs: CA UTION: Light bulbs become extremely hot when turned on. DO NO T touch bulbs until switc hed o and cooled. T ouching hot bulbs may cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip together, the lig ...

  • Zephyr CTP-E 60SX - page 21

    www .zephyronline.com T r ou b le S h oot in g 19 After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Filter is vibrating. After hood has been installed for a period of time, it stopped working. 1. The power so ...

  • Zephyr CTP-E 60SX - page 22

    20 www .zephyronline.com Halogen Bulb G U-10, 120V, 50W Z0B-0020 Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 Duct Cover Extension Kit Z1C-00TP List of Parts and Accessories Part Description Part # Accessory Description Part # ...

  • Zephyr CTP-E 60SX - page 23

    www.zephyronline.com Warranty One Y ear Service Repair W arr anty: F or one year from date of original purchase, we will provide free of charge, service labor to repair any failed parts or components due to manufacturing defects. T wo Y ears P arts W arranty: F or two years from date of original purchase, we will provide free of charge, nonconsumab ...

Fabricante Zephyr Categoría Ventilation Hood

Los documentos del dispositivo Zephyr CTP-E 60SX que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Zephyr
- manuales de instrucciones CTP-E 60SX
- hojas de producto Zephyr
- folletos informativos
- o etiquetas energéticas Zephyr CTP-E 60SX
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Zephyr CTP-E 60SX.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Zephyr CTP-E 60SX, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Zephyr CTP-E 60SX. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Zephyr CTP-E 60SX.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Zephyr CTP-E 60SX, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Zephyr CTP-E 60SX. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Zephyr CTP-E 60SX.

El manual de instrucciones completo de Zephyr debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Zephyr CTP-E 60SX - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Zephyr CTP-E 60SX, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Zephyr CTP-E 60SX que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Zephyr CTP-E 60SX - que deben facilitarnos los primeros pasos durante el uso de Zephyr CTP-E 60SX
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Zephyr CTP-E 60SX
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Zephyr CTP-E 60SX en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Zephyr CTP-E 60SX?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Zephyr CTP-E 60SX, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Zephyr CTP-E 60SX probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)