    INST ALLA TION INSTRUCTIONS OTL Report No. 116-F-32-5 Millivolt Models Electronic Models MODELS P/N 700,031M REV . C 11/2006 DIRECT VENT GAS FIREPLACE HEA TERS A French manual is available upon request. Order P/N 700,031CF Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 700,031CF . SSDVST ...

  • Trek SSDVST-CNM - page 2

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 2 T ABLE OF CONTENTS Packaging ......................................... Page 2 Introduction ...................................... Page 2 General Information .......................... Page 2 New Y ork City Approval ..................... Page 3 Requirements for the Commonwealth of Massachusetts ...

  • Trek SSDVST-CNM - page 3

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 3 New Y ork City , New Y ork (MEA) Installation of these fi replaces are approved for installation in New Y ork City in the US state of New Y ork. Input (BTU) Manually-Modulated Gas Valves (millivolt models) Models Fuel T ype Input Rate (BTU / HR) SSDVST SSDVPF Natural or Propane Gas 37,500 hig ...

  • Trek SSDVST-CNM - page 4

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Note: The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in ...

  • Trek SSDVST-CNM - page 5

    5 W ARNING Do not attempt to alter or modify the construction of the appli- ance or its components. Any modifi cation or alteration may void the warranty , certifi cation and listings of this unit. W ARNING Do not use these appliances if any part has been under water . Immediately call a qualifi ed, professional service technician to inspect the ...

  • Trek SSDVST-CNM - page 6

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 6 Figure 3 LOCA TION In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the outside atmosphere and access to the fuel supply are also im- portant. Consideration should be given to traffi c ways, furniture, draperies ...

  • Trek SSDVST-CNM - page 7

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 7 T ermination Heights For Vents Above Flat Or Sloped Roofs Ref. NFP A 54 / ANSI Z223.1, 7.6 Roof Pitch * Feet * Meters Flat to 6/12 1.0 0.3 6/12 to 7/12 1.25 0.38 7/12 to 8/12 1.5 0.46 8/12 to 9/12 2.0 0.61 9/12 to 10/12 2.5 0.76 10/12 to 11/12 3.25 0.99 11/12 to 12/12 4.0 1.22 12/12 to 14/12 5 ...

  • Trek SSDVST-CNM - page 8

    8 VENT TERMINA TION CLEARANCES EXTERIOR HORIZONT AL VENT TERMINA TION CLEARANCE REQUIREMENTS V V V V V F C B B A B H M I X V D V A A A V L B J X E V A G *18” 18” B C C C See Item D in the T ext Below. Center Line of T ermination Exterior Wall Horizontal T ermination Ventilated Soffi t Inside Corner DET AIL D Minimum Clearances Canadian Install ...

  • Trek SSDVST-CNM - page 9

    9 5 (127) 8-1/4 (209) 14 (356) 12 (305) 19 (483) MINIMUM CLEARANCES TO COMBUSTIBLES Maintain clearances from appliance to combustible materials as detailed in T able 7 , with the following exception: When the appliance is installed with one side fl ush with a wall, the wall on the other side of the appliance must not extend beyond the front edge o ...

  • Trek SSDVST-CNM - page 10

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 10 DET AILED INST ALLA TION STEPS TYPICAL INST ALLA TION SEQUENCE The typical sequence of installation follows, however , each installation is unique resulting in variations to those described. See the Page numbers references in the follow- ing steps for detailed procedures. Step 1 . ( Page 10 ) ...

  • Trek SSDVST-CNM - page 11

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 11 PRODUCT REFERENCE INFORMA TION Cat. No. Model Ship Wt. Ship. Volumn H3333 SSDVST -CNM 282 lbs 52W x 27D x 44- 1/2H (36.2 cu.ft). H3334 SSDVST -CNE 282 lbs 52W x 27D x 44- 1/2H (36.2 cu.ft). Figure 13 SPECIFICA TIONS Natural & Propane Gas BTU Input 37,500 (MV Low 30,000) Co-axial DV Vent S ...

  • Trek SSDVST-CNM - page 12

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 12 Figure 14 FIREPLACE SPECIFICA TIONS - SSDVPF (PENINSULA VIEW) Fireplace Framing Specifi cations 12 (305) 10 (254) 40-1/8 (1019) 3-1/2 (89) (16) FRAMING SPACERS (T op and Side) FINISH WALL BRACKET (Front, back, and left edge of unit top) 6-7/8 (175) 10-1/4 (260) 12 (305) (63.5) 3 (76) (13) 1/ ...

  • Trek SSDVST-CNM - page 13

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 13 Securing Screws (OUTSIDE of Appli ance) Insulation T op Vent Vent Seal Cap Firebox T op Cabinet T op CROSS SECTION SIDE VENT SEAL CAP REMOV AL (SIDE VENT INST ALLA TIONS ONL Y) Insulation Vent Seal Cap Securing Screws Side Vent Cabinet Back CROSS SECTION (INSIDE of Appli ance) (OUTSIDE of App ...

  • Trek SSDVST-CNM - page 14

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 14 Figure 18 SV4.5CGV-1 T ermination SV4.5F A or SV4.5FB Flashing and SV4.5SC Storm Collar 1” (25.4 mm) Minimum Clearance to Combustibles -1 ptSV4.5VF Firestop / spacer SV4.5L6 / 12 / 24 / 36 / 48 Vent Sections  When using Secure Flex use Firestop / spacer SF4.5VF 40 ft. Max. (12.2 M) 4 4 1 ...

  • Trek SSDVST-CNM - page 15

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 15 Blocking Support Straps (Plumber's tape) 8 feet (2.4 m) Maximum 1 inch (25.4 mm) minimum clearance to combustibles Figure 19 Figure 21 Another method, where the vent is not adjacent to a wall, is illustrated in Figure 22 . Here, support straps (96K93) and support plates (96K92) can be us ...

  • Trek SSDVST-CNM - page 16

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 16  SV4.5VF Firestop / spacer  SV4.5SU Support Strap 8 ft. (2.4 M) Maximum  SV4.5SP Support Plate Ceiling Framing  Secured to Vent with Appropriate Fasteners 1” (25.4 mm) Minimum Clearance to Combustibles  When using secure Flex, use Firestop/Spacer SF4.5VF Framing Dimensions fo ...

  • Trek SSDVST-CNM - page 17

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 17 H V V1 V H T able A H Maximum V Minimum feet (meter) feet (meter) 2 (0.610) 1 (0.305) 4 (1.219) 2 (0.610) 6 (1.829) 3 (0.914) 8 (2.438) 4 (1.219) V + H = 40 feet (12.2 meters) Max. H = 8 feet (2.4 meters) Max. Ratio V to H ratio is 1:2 T able B H Maximum V Minimum feet (meter) feet (meter) 5 ...

  • Trek SSDVST-CNM - page 18

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 18 T able D H + H 1 Maximum V Minimum feet (meter) feet (meter) 5 (1.524) Elbow Only 5 (1.524) 1 (0.305) 10 (3.048) 2 (0.610) 15 (4.572) 3 (0.914) 20 (6.096) 4 (1.219) H + H 1 = 20 feet (6.096 m) Max. V + V 1 + H + H 1 = 40 ft. (12.192 m) Max. Example: If 20 feet total (H+H 1 ) horizontal vent r ...

  • Trek SSDVST-CNM - page 19

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 19 HORIZONT AL (OUTSIDE WALL) TERMINA TION SYSTEM See Figure 32 , and Figures 35 to 40 and their associated Horizontal Vent T able which illustrates the horizontal venting confi gura- tions that are allowed to be used with these appliances. Secure Vent pipe applications are shown in these fi g ...

  • Trek SSDVST-CNM - page 20

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 20 IMPOR T ANT The vent termination is hot while in operation and for a period of time following the use of the fi re- place. T o prevent contact with hot surfaces, we recommend the use of a T ermination Guard . See Items 12 and 13 on Page 31. This can be purchased at your local dealer . It is ...

  • Trek SSDVST-CNM - page 21

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 21 Square termination (SV4.5HT -2) shown.  Wall Firestop / Spacer (SV4.5HF) W ARNING Under no circumstances, may separate sections of concentric fl exible vent pipe be joined together . See T able 11 as an aid in venting component selection for a particular range of exterior wall thicknesses ...

  • Trek SSDVST-CNM - page 22

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 22 H 1 V H V H H 1 T able F H +H 1 Maximum H Maximum V Minimum feet (meter) feet (meter) feet (meter) 5 (1.524) 2 (0.610) 1 (0.305) 10 (3.048) 4 (1.219) 2 (0.610) 15 (4.572) 6 (1.829) 3 (0.914) 20 (6.096) 8 (2.438) 4 (1.219) V + H + H 1 = 40 feet (12.2 m) Max H = 8 feet (2.438 meters) Max. H + H ...

  • Trek SSDVST-CNM - page 23

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 23 V H 2 H 1 H V H H 1 V 1  Wall Firestop / Spacer (SV4.5HF)  Ceiling Firestop / Spacer (SV4.5VF)  Ceiling Firestop / Spacer (SV4.5VF)  Wall Firestop / Spacer (SV4.5VF)  Wall Firestop / Spacer (SV4.5HF)  When using Secure Flex, use Firestop / Spacer SF4.5VF  When using Secur ...

  • Trek SSDVST-CNM - page 24

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 24 D . Install Firestop / Spacers at ceilings and walls - When Secure Flex penetrates a wall or ceiling, a fi restop / spacer is required: use the SF4.5 VF fi restop / spacer for ceilings and the SF4.5 HF fi restop / spacer for walls. See the appropriate sections and Figures shown throughout ...

  • Trek SSDVST-CNM - page 25

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 25 Figure 43 - Millivolt Wiring Diagram Field Wired Factory Wired TH TP TH TP * Optional Control Switch Thermopile Schematic Representation Only • If any of the original wire as supplied must be replaced, it must be replaced with T ype AWM 105 C - 18 gage wire. * Optional Kits Installed - ON/O ...

  • Trek SSDVST-CNM - page 26

    26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CAUTION Ensure that wires are positioned away from hot surfaces and sharp edges. CAUTION Do not connect the optional wall switch to a 120 Volt AC power supply . CAUTION Ground supply lead must be con- nected to the wire attached to the green ground screw located on the outlet box. See Figure ...

  • Trek SSDVST-CNM - page 27

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 27 Figure 48 TEST ALL CONNECTIONS FOR GAS LEAKS (F ACTORY AND FIELD): T urn on gas supply and test for gas leaks using a gas leak test solution (also referred to as bubble leak solution). Note: Using a soapy water solution (50% dish soap, 50% water) is an effective leak test solution but it is n ...

  • Trek SSDVST-CNM - page 28

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 28 Step 8. INST ALLING LOG SET , VOLCANIC STONE AND GLOWING EMBERS W ARNING Logs get ver y hot and will remain hot up to one hour after gas supply is turned off. Handle only when logs are cool. T urn off all elec- tricity to the appliance before you install grate and logs. W ARNING This applianc ...

  • Trek SSDVST-CNM - page 29

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 29 The log set foam package is located in the fi rebox and the bags of decorative volcanic stone and the glowing embers (rockwool) are located in the control compartment. Refer to the following information and Figures 52 and 54 for detailed placement instructions. Install the decorative volcani ...

  • Trek SSDVST-CNM - page 30

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 30 Ref. Air shutter Patent: U.S. Pat. 5,553,603 W ARNING Air shutter adjustment should only be performed by a qualifi ed profes- sional service technician. W ARNING Ensure glass panels are in place and sealed during adjustment. CAUTION Carbon/soot will be produced if the air shutter is closed t ...

  • Trek SSDVST-CNM - page 31

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 31 Item Cat. No. Model Description 1 H1968 SV4.5HT -2 Horizontal Square T ermination With Firestop / spacer (H2246) & Adapter (74L61) 2a H2152 SV4.5CGV-1 V ertical T ermination Cap 2b H4687 SV4.5CTS Chase T op T ermination Square 2b H4716 SV4.5CTS-B Chase T op T ermination Square, Black 2b H ...

  • Trek SSDVST-CNM - page 32

    32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Item Cat. No. Model Description 18 H1969 SF4.5HT -2 Horizontal Square T ermination (without fl ex) 18 77L87 SFKIT12S Flex Square T erm. (with 12 inch [305 mm] * compressed flex) 18 77L88 SFKIT18S Flex Square T erm. (with 18 inch [457 mm] * compressed flex) 18 77L89 SFKIT24S Flex Square T erm ...

  • Trek SSDVST-CNM - page 33

    33 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. GAS CONVERSION KITS IMPOR T ANT CANADA ONL Y The conversion shall be carried out in accordance with the require- ments of the provincial authorities having jurisdiction and in accor - dance with the requirements of the CAN1-B149.1 And B149.2 Installation code. Natural Gas to Propane Gas Conve ...

  • Trek SSDVST-CNM - page 34

    34 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. SIT Millivolt Gas Valve Pilot for SIT Millivolt Gas Valve Figure 60 b. Attach manometer to the manifold side pressure test fi tting and verify manifold pres- sure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas. c. Refer to Fi ...

  • Trek SSDVST-CNM - page 35

    NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 35 Figure 63 Figure 64 BURNER POSITIONING REAR BURNER FRONT BURNER PILO T BURNER Note: The burners are not identical. Position them so that the circular burner ports run as sho wn. Note especially the vertical run of ports relati ve to the pilot burner . Bracket A on the rear burner will interfe ...

  • Trek SSDVST-CNM - page 36

    Printed in U.S.A. © 2005 by LHP P/N 700,031M REV . C 11/2006 LHP reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information. LHP 1110 West T aft A venue • Orange, CA 92865 NOTE: ...

Fabricante Trek Categoría Indoor Fireplace

Los documentos del dispositivo Trek SSDVST-CNM que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Trek
- manuales de instrucciones SSDVST-CNM
- hojas de producto Trek
- folletos informativos
- o etiquetas energéticas Trek SSDVST-CNM
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Trek SSDVST-CNM.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Trek SSDVST-CNM, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Trek SSDVST-CNM. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Trek SSDVST-CNM.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Trek SSDVST-CNM, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Trek SSDVST-CNM. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Trek SSDVST-CNM.

El manual de instrucciones completo de Trek debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Trek SSDVST-CNM - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Trek SSDVST-CNM, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Trek SSDVST-CNM que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Trek SSDVST-CNM - que deben facilitarnos los primeros pasos durante el uso de Trek SSDVST-CNM
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Trek SSDVST-CNM
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Trek SSDVST-CNM en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Trek SSDVST-CNM?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Trek SSDVST-CNM, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Trek SSDVST-CNM probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)