    USSC 1 851576A CORN & PELLET MUL TIFUEL ST OVE 6035 OWNER’S MANUAL Installation - Operation - Maintenance Instructions - Repair Parts READ THIS ENTIRE MANUAL , THOROUGHL Y , BEFORE A T TEMPTING TO INST ALL AND/OR BURN YOUR NEW AMERICAN HARVEST CORN AND PELLET MUL TI-FUEL ST OVE. F AILURE T O FOLLOW THESE INSTRUCTIONS MA Y RESUL T IN PROPERTY ...

  • United States Stove 6035 - page 2

    2 USSC SPECIFICATIONS United States Stove Company ( manufacturer of the American Harvest Multifuel Pellet Stove ) reserves the right to alter products, specifications and price without notice. Safety T ested & Listed to ASTM- E 1509, ULC -C 1482, (UM) 84-HUD, by OMNI T est Laboratories, Inc. , B ea verton, Oregon USA NOTE: YOUR UNIT MUST BE INS ...

  • United States Stove 6035 - page 3

    USSC 3 Ashes will have to be Remov ed from the stove periodically . See cleaning procedure. Y ou can minimize cleaning required and maximize efficiency by maintaining the correct draft settings. See “Draft Setting” further in the manual. The draft setting on your stove may have to be changed from time to time to accommodate your specific burnin ...

  • United States Stove 6035 - page 4

    4 USSC SHELLED CORN (Dry , prefe rably corn with 11- 12% moisture content) • • • • • • Corn must contain less than 14% moisture content. Wet corn will rapidly deteriorate stove components, reduce efficiency and void all warranties. Purchase a moisture tester if in doubt. Corn must be clean and free from debris. Never burn corn right fro ...

  • United States Stove 6035 - page 5

    USSC 5 FLOOR PROTECTION The American Harvest Multifuel Stove may be installed on a combustible floor , with proper floor protection, or on a masonry hearth. The hearth or noncombustible floor protector must extend a minimum of (6) inches (152mm)in front and (6) inches (152mm) from each side of the ash remov al door . INSTALLATION REQUIREMENTS CLEAR ...

  • United States Stove 6035 - page 6

    6 USSC CLEARANCES TO COMBUSTIBLES continued... 6” min. The side and top clearance are to be used when installing in an Alcove as shown to the left and below. HEARTH PROTECTION GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN • • • • • A listed 3” or 4” type “PL ” pellet vent exhaust system must be used for FREEST ANDING installatio ...

  • United States Stove 6035 - page 7

    USSC 7 GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN continued... • • • • • • • Distance from bottom of termination and grade-1ft./305mm minimum. This is conditional upon the plants and nature of grade surface. The exhaust gases are not hot enough to ignite grass, plants or shrubs located in the vicinity of the termination. The grade ...

  • United States Stove 6035 - page 8

    8 USSC For installations with horizontal through-the-wall exhaust, it is strongly recommended that the stove combustion air be connected to the outside. If the home is newer or has been tightly insulated it is required to install outside combustion air . If you do not, then bring a 4-6 inch intak e into the furnace room in the basement. Connection ...

  • United States Stove 6035 - page 9

    USSC 9 Note: Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA -B365 The American Harvest Corn/Pellet Stove Model 6035 may be installed as follows: 1) A freestanding unit 2) A built-in heater mounted in an alcove MOBILE HOME INSTALLATION REQUIREMENTS IN ADDITION TO THE STAND ...

  • United States Stove 6035 - page 10

    10 USSC ALCOVE INSTALLATION REQUIREMENTS The American Harvest is approved for the standard alcove height of 52 inches, or for a reduced alcove height with a minimum of 19 inches from the top of the stove (clearance for opening top lids). The maximum alcove depth is 48 inches and the listed clearances are a minimum of 6” on the left side, 2” on ...

  • United States Stove 6035 - page 11

    USSC 11 Locate proper position f or the type “PL ” wall thimble (F). Use a saber saw or keyhole saw to cut a 7 1/4-inch diameter hole through the wall (E) for a 3-inch pipe. For a 4-inch pipe, cut an 8 1/4-inch hole. Install the wall thimble (F)in the hole. The size of hole opening will vary with brand of wall thimble. P osition stove approxima ...

  • United States Stove 6035 - page 12

    12 USSC 6” Min. Non Combustible Hearth Plate 6” Min. Fresh Air Intake (Optional 60F AK) With 90 Degree Elbow or Hood (Pest Guard 3/8” Mesh Maximum) Clean Out Cover Te e 3” Min. Wall Thimble Flashing Rain Cap or T ermination Cap Storm Collar 24” Min. INSIDE VER TICAL PIPE WITH ROOF TERMINA TION NOTE: V ertical Pipe must be 4” PL Above 6? ...

  • United States Stove 6035 - page 13

    USSC 13 24” Min. Flashing Rain Cap or T ermination Cap Storm Collar Wall Thimble Fresh Air Intake (Optional 60F AK) With 90 Degree Elbow or Hood (Pest Gaurd, 3/8” Mesh Maximum) Clean Out Cover Te e Wall Thimble 6” Min. Non Combustible Hearth Plate Support Bracket Every 5 Feet 1” Min. Keep Attic Insulation Away From Pipe THROUGH THE WALL, VE ...

  • United States Stove 6035 - page 14

    14 USSC Y our American Harvest Corn/Pellet Stove comes to you with the glass door installed in place, ready for use. The glass is surrounded on the edges with a gasket and seated in a glass channel. It is held in place with four (4) clips. REMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS Open the door and lift off of hinges. If the door is tight, tap gen ...

  • United States Stove 6035 - page 15

    USSC 15 STOVE CONTROLS Adjustable Door Handle lifts up and turns left to open. Ash Dump Shutoff Pull out to empty ashes out of the firebox area and back heat exchanger area. Make sure to push all the way in when done. Front View Left/Front View Circuit Board Control Panel Open door to access the controls Manual Draft Adjustment Slide in or out to a ...

  • United States Stove 6035 - page 16

    16 USSC LIGHTING INSTRUCTIONS Before lighting your American Harvest for the first time, make sure that all items are out of the hopper and firebox area. T urn the heat settings knob to the off position and push the manual draft in as far as it will go. Note: If using a wall thermostat option make sure that the thermostat is turned up above room tem ...

  • United States Stove 6035 - page 17

    USSC 17 CIRCUIT BOARD FUNCTIONS !! !! !! !! !! CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL !! !! !! !! !! Start-up When the circuit board is energized (unit plugged in) there is a 15 second purging of the auger tube to allow fuel to enter the firepot. T o initiate the Start-up, turn the heat setting knob to the number 3 set ting. If the unit is st ...

  • United States Stove 6035 - page 18

    18 USSC SETTING THE DRAFT A proper draft setting is crucial to the successful burning of solid fuels. Draft refers to the amount of air flowing through the burn chamber of your stov e. T oo much or too lit tle draft will cause your stove to burn improperly and may r esult in the fire burning out or excessive deposits (clinkers). Please follow these ...

  • United States Stove 6035 - page 19

    USSC 19 Maintenance Instructions Continued... SPECIAL CLEANING/OPERATIONAL INSTRUCTIONS: After cleaning or when operating the unit you need to make sure that the clean-out plates are in the closed position. Push the front (2) clean-out slides all the way in and make sure that you have replaced the left & right clean-out plates that are located ...

  • United States Stove 6035 - page 20

    20 USSC WARNING These automatic safety features must not be bypassed Micro Switch The hopper auger safe ty switch is mounted in the back of the hopper , up next to the back lid. The assembly is enclosed to keep the fuel fr om entering the switch locale. When the lid is opened it cuts power to the auger motor . Power is resumed when the lid is close ...

  • United States Stove 6035 - page 21

    USSC 21 THERMOSTAT INSTALLATION • • • • • The American Harvest can be installed with and operated by a wall-mounted thermostat (Optional WT47) which may be purchased from your dealer or from USSC. The wall thermostat needs to be for a low voltage system. Most thermostats will have instructions with them as to where to place them in your r ...

  • United States Stove 6035 - page 22

    22 USSC TROUBLE SHOOTING Unplug stove before preforming any maintenance work PROBLEM CAUSES SOLUTIONS ? Fire burns with a lazy , orange flame and/or fuel builds up in the firepot • • • • • • • Insufficient combustion air Feed rate too high Corn or wood pellets have too much moisture Combustion/Exhaustion blower plugged or going out V ...

  • United States Stove 6035 - page 23

    USSC 23 TROUBLE SHOOTING continued... PROBLEM CAUSES SOLUTIONS ? Fire goes out or stove shuts down automatically . • • • • • Hopper is empty . Fuel is not feeding. High limit temperature switch has tripped. Combustion air too high. Fuel feed rate is too low. • • • • R efi ll hopper . See “Pellets will not feed” below Allow sto ...

  • United States Stove 6035 - page 24

    24 USSC CAUTION: When performing any internal electrical maintenance • Moving parts inside of the cabinet may cause injury . Do not operate unit with panels remov ed or open. • HOT parts. Do not operate the unit with panel open. • Risk of electric shock. Disconnect power before servicing unit. • In the event of component failure, replace wi ...

  • United States Stove 6035 - page 25

    USSC 25 WIRING DIAGRAM ...

  • United States Stove 6035 - page 26

    26 USSC REPAIR PARTS DIAGRAM-6035 ...

  • United States Stove 6035 - page 27

    USSC 27 REPAIR PARTS LIST-6035 K EY PAR T # DESCRIPTION QTY. 1 25108B Pedestal Base, Painted 1 2 25171B Ash Pan Guide, Painted 1 3 25158B P edestal T rim, Painted 1 4 25109B Pedestal, Painted 1 5 25167B Pedestal Back, Painted 1 6 69364B Ash Pan, Painted 1 7 69419 Hopper Assembly 1 8 80315 Pressure Switch 1 9 80463 Hopper Lid Switch 1 10 86594 Hoppe ...

  • United States Stove 6035 - page 28

    28 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPEND- ABLE SERVICE FROM YOUR AMERICAN HARVEST, AND EN- ABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFER- ENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER. WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE ...

Fabricante United States Stove Categoría Stove

Los documentos del dispositivo United States Stove 6035 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos United States Stove
- manuales de instrucciones 6035
- hojas de producto United States Stove
- folletos informativos
- o etiquetas energéticas United States Stove 6035
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones United States Stove 6035.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje United States Stove 6035, instrucciones de servicio, instrucciones cortas o instrucciones de usuario United States Stove 6035. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto United States Stove 6035.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo United States Stove 6035, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar United States Stove 6035. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de United States Stove 6035.

El manual de instrucciones completo de United States Stove debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual United States Stove 6035 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice United States Stove 6035, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de United States Stove 6035 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo United States Stove 6035 - que deben facilitarnos los primeros pasos durante el uso de United States Stove 6035
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con United States Stove 6035
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de United States Stove 6035 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de United States Stove 6035?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con United States Stove 6035, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con United States Stove 6035 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)