    ® Section 61180403L1-5B Issue 2, December 2004 CLEI Code: VAIMZ70J_ _ 61180403L1-5B 1 Trademarks: Any brand names and product name s included in this docum ent are trademarks, regi stered tradem arks, or trade nam es of their respecti ve holders. CONTENT S 1. General ................... .................. ...................... ......... 1 2. Inst ...

  • ADTRAN 1109403L2 - page 2

    2 Issue 2, December 2004 61180403L1-5B •P L A R D 3 •T a n d e m •D P O • FX Ringdown • TO w/Sealing Code Features The basic features of the FXS/DPO include the following: • µ -law encoding and decoding • Supports ground start, lo op start, PLAR, DPO, and Tandem, TR08SP, TR08UVG, TR08AUTO, and FX Ringdown • Supports 900 ohm s (+2.1 ...

  • ADTRAN 1109403L2 - page 3

    61180403L1-5B Issue 2, December 2004 3 Instructions for Inst alling the Module To install the FXS/DPO, perform the following steps: 1. If pres ent, remove the Access Module Blank (P/N 1 175099L1) from the appropriate access module slot of the T otal Acce ss chassis. 2. Pull the ejector latch, located on the lower left- hand side of the FXS/DPO fron ...

  • ADTRAN 1109403L2 - page 4

    4 Issue 2, December 2004 61180403L1-5B Hardware Provisioning DIP switches SW1 , SW2 , SW3 , and SW4 are used to provision many of the FXS/DPO options. Ta b l e 4 on page 5 summ arizes the options pro visioned by the DIP switches. Figure 2 o n page 6 provides a grap hic detail of the four switches and the printed circuit board markings. NOTE Manual ...

  • ADTRAN 1109403L2 - page 5

    61180403L1-5B Issue 2, December 2004 5 T able 4. DIP Switches Sw .-Segment Label Function/Desc ription 1-1 D3/D4 D3 or D4 Signaling (PLAR only) 1-2 1-3 MODE 1/OFF MODE 2/OFF SW1-2 SW1-3 Mode Selected OFF OFF FXS OFF MODE 2 DPO MODE 1 OFF T andem MODE 1 MODE 2 PLAR 1-4 GS/LS Ground Start or Loop S tart 1-5 AUTO_TERM/OFF Reserved for future use 1-6 9 ...

  • ADTRAN 1109403L2 - page 6

    6 Issue 2, December 2004 61180403L1-5B Figure 2. DIP Switches Detail Sof tware Provisioning The FXS/DPO is provisioned by connecting a VT100 terminal or a computer ru nning a terminal emulation program to the craft interface ADMIN port located on the System Controller Unit (SCU ) front panel. Connection to the port is made via a RS-232, DB-9 cable ...

  • ADTRAN 1109403L2 - page 7

    61180403L1-5B Issue 2, December 2004 7 . T able 5. FXS/DPO General Opti ons Function Optio n Description Mode Loop S tart Ground Start TR08 Single Part y (3) TR08 Universal VG (3) TR08 Auto (3) PLAR D4 PLAR D3 Ta n d e m (3) DPO FX Ringdown (3) TO w /S C (3) This option selects the signaling mode of the FXS/DPO. See T able 6 for detailed descriptio ...

  • ADTRAN 1109403L2 - page 8

    8 Issue 2, December 2004 61180403L1-5B T able 6. FXS/DPO Mode Options Mode Description Loop Start This option selects ANSI T1.403 FXS Loop S tart mode of operation. Ground Start This option selects ANSI T1.403 FXS Ground Start mode of operation. TR08 Single Party This option selects GR-08-Core Loop S tart mode of operation. TR08 Universal VG This o ...

  • ADTRAN 1109403L2 - page 9

    61180403L1-5B Issue 2, December 2004 9 T able 7. FXS/DPO T andem Options Function Option Description Conversion Mode T andem Inactive Loop Start Ground Start This option sets the conversion from E&M (2-state) signali ng on the PCM interface to loop star t or ground start signaling on the loop. This option MUST be configured for channel operatio ...

  • ADTRAN 1109403L2 - page 10

    Figure 3. FXS/DPO Menu Tree 1. Configuration 2. Provisioning 3. Status 4. Test 1. Digital Network Loopback 2. 1004 Hz Tone Test 2. 2-Wire Termination 1. 600 + 2.16 2. 900 + 2.16 Enter Value (-7.0...+9.0) 3. Transmit TLP 1. Loop Start 3. TR08 Single Party 2. Ground Start 5. TR08 Auto 4. TR08 Universal VG 6. PLAR D4 8. Tandem 7. PLAR D3 10. FX Ringdo ...

  • ADTRAN 1109403L2 - page 11

    61180403L1-5B Issue 2, December 2004 11 4. T EST FEATURES The FXS/DPO supports the following tests for each port: • Digital Network Loopback • 1004 Hz Tone Generation • Network Hook Test • Customer Ringing Test These test are used to support circuit turn-up and maintenance efforts. Test functions can be activated locally via the ADMIN port ...

  • ADTRAN 1109403L2 - page 12

    12 Issue 2, December 2004 61180403L1-5B T able 8. Specifications Performance Loop Current: T ransmit TLP: Receive TLP: T erminating Impedance: Return Loss: T ransHybrid Loss: Longitudinal Balance: Frequency Response: Idle Channel Noise: PCM Encoding/Decoding: DC Supervisory Range: 23 mAmp nom inal 20 mAmp minimum –7.0 to +9 .0 dBm –9.0 to 0.0 d ...

Fabricante ADTRAN Categoría Network Card

Los documentos del dispositivo ADTRAN 1109403L2 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ADTRAN
- manuales de instrucciones 1109403L2
- hojas de producto ADTRAN
- folletos informativos
- o etiquetas energéticas ADTRAN 1109403L2
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ADTRAN 1109403L2.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ADTRAN 1109403L2, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ADTRAN 1109403L2. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ADTRAN 1109403L2.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ADTRAN 1109403L2, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ADTRAN 1109403L2. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ADTRAN 1109403L2.

El manual de instrucciones completo de ADTRAN debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ADTRAN 1109403L2 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ADTRAN 1109403L2, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ADTRAN 1109403L2 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ADTRAN 1109403L2 - que deben facilitarnos los primeros pasos durante el uso de ADTRAN 1109403L2
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ADTRAN 1109403L2
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ADTRAN 1109403L2 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ADTRAN 1109403L2?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ADTRAN 1109403L2, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ADTRAN 1109403L2 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)