Manual de instrucciones ICP DAS USA MSM-508

27 de páginas 0.85 mb
Descargar

Pasar a la página of 27

Summary
  • ICP DAS USA MSM-508 - page 1

    April 29, 2008 TM Web Management Us er Manual Industrial Managed Ethernet Switch Version 1.0 This document applied to models of MSM-5 08,MSM-508FC /FCS/FT C o p y r i g h t © I C P D A S C o . , L t d . , A l l R i g h t s R e s e r v e d . ...

  • ICP DAS USA MSM-508 - page 2

    April 29, 2008 CONTENTS 1. Web Connectio n .......................................................................... 2 2. Basic Setting ............................................................................... 4  Informati on ............ ............ ............ ....... ............ ............ ............ . 4  Network ............ ...

  • ICP DAS USA MSM-508 - page 3

    April 29, 2008 10. Authentication ..................................... ..................................... 22  Account ........ ............ ............ ........... ........ ............ ............ ......... 22  Accessi ble IP ....................... ............ ....... ............ ............ ........... 2 3  Defaul t Setting ... ...

  • ICP DAS USA MSM-508 - page 4

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 1  Connection  Basic Setting  Redundant Setting  Port configurat ion  Relay Alarm  Email Alarm  VLAN  QoS  Diagnosis  Authentication Managed S witch W eb Mana gement Op eration This m anual will guide you how to conf igure ICPDAS M ...

  • ICP DAS USA MSM-508 - page 5

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 2 1. W eb Connection The default net work setting (fac tory default setting) of Manage d Switch is : IP : 192.168.255.1 Mask : 255.255.0.0 Gatewa y : 192.168.0.1 Before access ing Managed Switch thro ugh web bro wser , please m odify above setting to fit your n ...

  • ICP DAS USA MSM-508 - page 6

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 3 For log in to Web Managem ent, your browser m ust support HTTP authentication. It a llows a web browser t o provid e credentials when m aking a request. ...

  • ICP DAS USA MSM-508 - page 7

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 4 2. Basic Setting This chapter desc ribes ho w to setting the c omm only inform ation on your Managed Switch.     Information Module Name : : : : Use to specif y the Switch N ame, and als o displa yed as the console prom pt. Max. 8 characte ...

  • ICP DAS USA MSM-508 - page 8

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 5 Onl y MS Series Switch s upports a real tim e clock . For RS Series S witch, the <Date Ti m e Setting> f unction is inval id.     Network IP Address : : : : IP address is an identifier f or a de vice on a TCP/IP network . It is a 32- ...

  • ICP DAS USA MSM-508 - page 9

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 6 Mask : : : : The (subnet) M ASK is used to determ ine the subnet of an IP address. Same as th e IP address, a MASK contains four bytes (32 bit s) and it is often ex pressed in the dotted-decim al notation. The fac tory default value is labeled bes ide ...

  • ICP DAS USA MSM-508 - page 10

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 7 COM1 port is t he RS232 standar d, use for Co nsole Connec tion. Factor y default setti ng is: Baud Rate : 1 15 200 Data Bit : 8 Parity Check : 0 (None) S top Bit : 1 COM2 is the R S485 standard, use f or Modbus com m unication. Factor y default setting is: B ...

  • ICP DAS USA MSM-508 - page 11

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 8 3. Redund ant Setting Redundant LAN t opolog y is a structur e to provide t he link failure recover y and escaping n etwork loops. It allows you t o setup the re dundant l oops for supporting bac kup connect ions. Managed Switch offers redundanc y options for ...

  • ICP DAS USA MSM-508 - page 12

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 9     Recovery T i me Setting Recovery Time (C yber-Ring Prot ocol) : : : : Recover y time is the durat ion of conn ections that f rom failure oc curred to retur n to norm al. This f unction allows you to assign the r ecover y time in m illi ...

  • ICP DAS USA MSM-508 - page 13

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 10 Forward Time (ST P Protocol) : : : : Forward dela y is the durati on tim e that packages from pre- forwarding s tate to forward state. Factory default is 10000ms , the variable is from 4000ms to 3 0000m s (30 sec). Setti ng is only available on STP M ...

  • ICP DAS USA MSM-508 - page 14

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 1 1 4. Port configuration     Mirror Mirror Port sett ing is comm onl y used to m onitor the network traffic, it can help you to collect and trace abnorm al packets of each port without interrup ting data transm ission. User can specif y a switch p ...

  • ICP DAS USA MSM-508 - page 15

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 12     T runking This f unction is used for s etting the groups of link aggregation . Port trunk ing allows user to combine m ultiple ph ysical ports into a single l ogical cha nnel. It can inc rease the link speed and provide the bet ter redunda nc ...

  • ICP DAS USA MSM-508 - page 16

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 13 Port P ort Num ber Speed P ort transm ission speed. ( 10 Mbps / 100 M bps ) Duplex Fl ow Control M ode. Both H alf-duplex an d Full-duplex modes ar e supported. Link P ort Link s tatus. ON : Link is up ; OFF : Link is do wn.     Cable Check ...

  • ICP DAS USA MSM-508 - page 17

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 14 5. Relay A larm Managed Switch offer a relay contact output on T erminal Block of the Switch equipm ent. It is able to connect to a l ight, bu zzer …etc. warnin g device and notify s ystem f ailures imm ediately . We also offer the web tool to c onfigure t ...

  • ICP DAS USA MSM-508 - page 18

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 15 6. Email A larm ICPDAS Manag ed Switch c an notify you by email whe n the specif ied event occ urred. This chapter will guide you how to sett ing the related parameter s.     Alarm Event setting User can specif y s y stem and port events that war ...

  • ICP DAS USA MSM-508 - page 19

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 16     Email Setting User can selec t “Disable A larm Mail” to stop the em ail alarm sending (f actory default). If email alarm is enabled, th ere are two m ethods of em ail report for you select. The firs t one is: warning m ail is sent imm edi ...

  • ICP DAS USA MSM-508 - page 20

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 17     Email Record Switch Managem ent can k eep the sending date, tim e and status of each w arning em ails. But only the lat est 50 send ing records will be saved. User can click the “Clean R ecord T able” button to de lete all t he email send ...

  • ICP DAS USA MSM-508 - page 21

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 18 7. VLAN Virtual LANs (VLAN) allows you to setting logical groups of devices, even they are not located on the same physical segment. The logical group called a VLAN, a ll devices be long to the VLAN has the same net work attribute s, and it’s isolated fr o ...

  • ICP DAS USA MSM-508 - page 22

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 19     Port based VL A Ns In this function , user can de term ine the output ports whic h this input port c an send fr ames to. For example, in above figure, onl y the ingress come fr om Port 4 and Port 8 can be send out from Port 1.     ...

  • ICP DAS USA MSM-508 - page 23

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 20 8. QoS Quality of Ser vice (QoS) pr ovides diff erent priority to di fferent data flow . It can m ake you to classif y and prioritize data fram es. ICPDAS Manag ed Switch s upport 4 classes of servic es priorit y queues. This f unction allows you to determ i ...

  • ICP DAS USA MSM-508 - page 24

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 21 IP T oS/DiffServ Enable/Disabl e specified p orts using the TOS (T ype of Service) a nd/or DiffServ (Differentiated Service) f ield in IPv4 fr ame. 802.1p T ag over T os/Diff Serv If <802.1p T ag Priorit y> and <IP T oS/Di ffServ> are both enable ...

  • ICP DAS USA MSM-508 - page 25

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 22 9. Diagnosis     Ping In this function , user can in put the IP address and cl ick SUMIT button to c heck if the IP is reachable. 10. Authentication     Account There are t wo levels of aut hentication ar e provided i n Switch Ma nage ...

  • ICP DAS USA MSM-508 - page 26

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 23 At the system initial, the def ault account and password are: Admin and A dmin .     Accessible IP Y ou can set the rem ote IP address here to f ilter the illega l access. O nly the IP address in following table can be allowed to acc ess Manage d ...

  • ICP DAS USA MSM-508 - page 27

    Industrial Ether net La yer 2 Manage d Switch – Web Ma nagement M anual April 29, 2008 24     Default Setting This f unction allows you to clean all sett ings and lo ad the def ault value to S witch Managem ent. Current factor y default val ues are : Netwo rk Setting IP A ddress : 192.168.255.1 Gatewa y : 192.16 8.0.1 Mask : 255.255 ...

Fabricante ICP DAS USA Categoría Switch

Los documentos del dispositivo ICP DAS USA MSM-508 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos ICP DAS USA
- manuales de instrucciones MSM-508
- hojas de producto ICP DAS USA
- folletos informativos
- o etiquetas energéticas ICP DAS USA MSM-508
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones ICP DAS USA MSM-508.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje ICP DAS USA MSM-508, instrucciones de servicio, instrucciones cortas o instrucciones de usuario ICP DAS USA MSM-508. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto ICP DAS USA MSM-508.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo ICP DAS USA MSM-508, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar ICP DAS USA MSM-508. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de ICP DAS USA MSM-508.

El manual de instrucciones completo de ICP DAS USA debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual ICP DAS USA MSM-508 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice ICP DAS USA MSM-508, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de ICP DAS USA MSM-508 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo ICP DAS USA MSM-508 - que deben facilitarnos los primeros pasos durante el uso de ICP DAS USA MSM-508
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con ICP DAS USA MSM-508
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de ICP DAS USA MSM-508 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de ICP DAS USA MSM-508?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con ICP DAS USA MSM-508, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con ICP DAS USA MSM-508 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)