Manual de instrucciones Agilent Technologies PN 8510-16

12 de páginas 0.38 mb
Descargar

Pasar a la página of 12

Summary
  • Agilent Technologies PN 8510-16 - page 1

    Agilent PN 8510-16 Controlling T est Port Output Power Flatness Product Note UNCORRECTED POWER CORRECTED POWER OUTPUT POWER Agilent 8510C Network Analyzer ...

  • Agilent Technologies PN 8510-16 - page 2

    2 Introduction Designers and manufacturers of active devices oft en need to control the pow er lev el at the t est port 1 of t heir pow er -sensitive devices, but f ind dif- ficulty in o vercoming inser tion losses. The insertion losses occur as a result of connecting components in the measurement pat h between the source and the DUT . The A gilent ...

  • Agilent Technologies PN 8510-16 - page 3

    3 System Configuration The basic 8510C measurement system conf igura- tion needed for test por t f latness correction is sho wn in Figure 1. A sing le channel pow er meter such as the A gilent 437B, E4418A, or E4418B is required, along with a compatible sensor , for per- forming t he po wer f latness calibration. Po wer meters with t he 437B comman ...

  • Agilent Technologies PN 8510-16 - page 4

    4 Flatness-Correction Operation The basic setup procedure t o obtain f lat t est port output po wer is illustrated in Table 1. To simplify the execution of t he procedure, t he front panel hardk eys are enclosed in [brackets]. The sof tkeys are enclosed in {braces}. Table 2 pro vides t he pro- cedure for setting up the pow er meter . The net- w ork ...

  • Agilent Technologies PN 8510-16 - page 5

    5 T able 1. Flatness-correction calibration procedure 8510C Keystrokes Description Set up the power meter (see T able 2) For proper operation, the E4418B must be set up before initiating the flatness-correction routine. See T able 2 for specific instructions. V erify the power meter's address on the 8510 system [LOCAL] When shipped from the fa ...

  • Agilent Technologies PN 8510-16 - page 6

    6 T able 2. Agilent E4418B power meter setup E4418B Keystrokes Description Preset and zero the power meter [PRESET/LOCAL] Return the power meter to a known state. {CONFIRM} [ZERO/CAL] {ZERO} Set up the 437B emulation on the power meter [SYSTEM/INPUTS] The 437B command set must be activated in order to perform the power flatness calibration. Power m ...

  • Agilent Technologies PN 8510-16 - page 7

    7 The follo wing er ror messages may occur while attempting t o enable the f latness cor rection and/or reducing the test por t pow er level: • If f latness cor rection is enabled before reducing the test por t pow er level, IF Overload or Source 1 W arning—RF Unleveled ma y be display ed on the analyzer as the source becomes unlev eled. U nlev ...

  • Agilent Technologies PN 8510-16 - page 8

    8 V erifying a flatness-correction calibration T o verify t he f latness-correction calibration, t he po wer sensor should be reconnected t o the t est port t o measure the t est por t po wer at individual frequencies. Since the measurement system is calibrated in 50W , inaccuracies will occur when a device is not well mat ched. Since the f latness ...

  • Agilent Technologies PN 8510-16 - page 9

    9 Using test port 1 calibrations on test port 2 In most cases, port 1 will be t he input por t of t he DUT . When por t 2 must be used as the input por t to t he device, t he user may choose to use a por t 1 f latness-cor rection calibration on por t 2 since the port 1 and por t 2 signal pat hs are symmetrical. 1 Figure 3 illustrates t he use of po ...

  • Agilent Technologies PN 8510-16 - page 10

    10 Practical Application Examples Absolute output power measurements with flatness correction One benefit of t he f latness-correction capability is the ability t o measure the absolute output pow er of active devices. Since the input pow er level to t he DUT is kept constant, t he magnitude of fset feature of the A gilent 8510 can be used to displ ...

  • Agilent Technologies PN 8510-16 - page 11

    11 Amplifier measurement example Step-by-step instr uctions for setting up and apply- ing f latness cor rections for t he measurement of an amplifier are sho wn in Table 7 . Gain, absolute output po wer , and gain compression measurements procedures are cov ered. For more information on measuring amplifiers, refer to A gilent product not e 8510-18, ...

  • Agilent Technologies PN 8510-16 - page 12

    Agilent T echnologies’ T est and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. W e strive to ensure that you get the test and measurement capabilities you paid for and obt ain the suppor t you need. Our ext ensive suppor t resources and services ...

Fabricante Agilent Technologies Categoría Power Supply

Los documentos del dispositivo Agilent Technologies PN 8510-16 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Agilent Technologies
- manuales de instrucciones PN 8510-16
- hojas de producto Agilent Technologies
- folletos informativos
- o etiquetas energéticas Agilent Technologies PN 8510-16
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Agilent Technologies PN 8510-16.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Agilent Technologies PN 8510-16, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Agilent Technologies PN 8510-16. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Agilent Technologies PN 8510-16.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Agilent Technologies PN 8510-16, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Agilent Technologies PN 8510-16. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Agilent Technologies PN 8510-16.

El manual de instrucciones completo de Agilent Technologies debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Agilent Technologies PN 8510-16 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Agilent Technologies PN 8510-16, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Agilent Technologies PN 8510-16 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Agilent Technologies PN 8510-16 - que deben facilitarnos los primeros pasos durante el uso de Agilent Technologies PN 8510-16
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Agilent Technologies PN 8510-16
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Agilent Technologies PN 8510-16 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Agilent Technologies PN 8510-16?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Agilent Technologies PN 8510-16, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Agilent Technologies PN 8510-16 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)